![KOGANEI CORPORATION HV160E1-2 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/koganei-corporation/hv160e1-2/hv160e1-2_instruction-manual_1986829002.webp)
Dimensions
(mm)
Handling Instructions and Precautions
Flow Rate
Solenoid
Replacement
of valves
Continuously energized time
The high cycle solenoid valve
construction allows solenoid and
valve body can be removed from the
base (piping portion), which means
that the valve can easily be replaced
without removing the piping.
Loosen the 4 mounting screws on the
top of the valve, and remove the
solenoid and valve body from the
base.
In high cycle solenoid valves, ener-
gizing continuously for too long can
result in reduced performance or
valve shutdown. Continuously ener-
gized time should be limited to 30
seconds or less.
In addition, maintain the duty ratio
(ON time/OFF time) at 1.0 or below. If
your application requires continuous
energizing in excess of the above
recommendations, consult us.
The order code for the replacement
valve body only (including solenoid) is
HV160E1-2-M
.
Caution:
Do not attempt to dis-
assemble the valve body.
Solenoid
Lead wire: Red
40
1(P)
2-Rc1/4
54
10
48
10
2(A)
38
30
Approximately
300
4-M5
×
0.8 Depth 6
Mounting thread
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
200
400
600
800
MPa
Supply pressure
(
MPa
)
Flow rate
R
/min(ANR)
V
alv
e outlet pressure
1MPa = 145psi., 1
R
/min = 0.0353ft.
3
/min.
Internal circuit