IMPORTANT SAFEGUARDS

Use this appliance only as described in this instruction manual. As with all electrical equip-
ment, whilst the instructions aim to cover as many eventualities as possible, caution and
common sense should be applied when operating and installing this appliance.
This appliance is designed for home air conditioning and must not be used for other pur-
poses 
It is dangerous to modify or alter the characteristics of the appliance in any way.
The appliance must be installed in conformity with national legislation regulating electrical
equipment and installations.
If the appliance requires repair, contact a Service Centre authorised by the manufacturer
only. Repairs carried out by unauthorised personnel may be dangerous.
This appliance must be used exclusively by adults. 
Never allow the appliance to be used by people (including children) with psychological,
physical or sensory impairments or with insufficient experience and knowledge, unless clo-
sely  supervised  and  instructed  by  someone  responsible  for  their  safety.  Young  children
should be supervised to ensure that they do not play with the appliance.
The appliance must be connected to an efficient earth system. Have your electrical circuit
checked by a qualified electrician.
Do not use extension cables. 
Before cleaning or maintenance, always unplug the appliance from the mains socket. 
Never unplug the appliance by pulling on the power cable. 
Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sour-
ces of heat 
Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pres-
surised containers (eg aerosol cans). 
Do not rest heavy or hot objects on top of the appliance. 
Clean the air filter at least once a week. 
Avoid using heating appliances near the air conditioner.
Always transport the appliance upright or resting on one side. Before moving the applian-
ce, empty the internal circuit completely of water. After moving the appliance, wait at least
1 hour before starting it.
When putting the appliance away, do not cover with plastic bags. 
The materials used for packaging can be recycled. You are therefore recommended to dis-
pose of them in special differentiated waste collection containers.
At the end of its working life, consign the appliance to a specialist collection centre.
If the power cable is damaged, it must be replaced by the manufacturer or an authorised
technical service centre in order to avoid all risk.

1

Содержание KGNPAC34VAA

Страница 1: ...KGNPAC34VAA USER MANUAL...

Страница 2: ...ng For Use Description Of The Control Panel Description Of The Remote Control Self diagnosis Tips For Correct Use Cleaning Start End Of Season Operations Troubleshooting Technical Specifications 6 9 O...

Страница 3: ...e appliance must be connected to an efficient earth system Have your electrical circuit checked by a qualified electrician Do not use extension cables Before cleaning or maintenance always unplug the...

Страница 4: ...aterials to be recove red to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled...

Страница 5: ...Air exhaust hose housing 9 Condensate drain 10 11 Flange Cap 12 Air exhaust hose 13 Window outlet 14 Suckers 15 Castor locks 16 Remote control 5 RESET ON OFF MODE POWERFUL SWING SLEEP TIMER FAN COOL...

Страница 6: ...or French window Adjust the length of the hose to reach the window Make sure the air exhaust hose is unobstructed Open the window or French window slightly and position the outlet fig 2 If you have a...

Страница 7: ...sula te the section of wall using suitable insulation Fit the flange accessory provided in the hole following the indications in figs 7 8 and 9 Fit the hose in the housing at the back of the appliance...

Страница 8: ...appear Never turn the air conditioner off by unplugging from the mains Always press the button then wait for a few minutes before unplugging This allows the appliance to perform a cycle of checks to v...

Страница 9: ...ion AUTO FAN the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display The most suitable temperature for the room during the summer vari...

Страница 10: ...t temperature 13 27 by pressing the or button until the corresponding value is displayed Symbol In heating mode the fan speed is selected automatically by Water is removed from the air and collected i...

Страница 11: ...direct sunlight or sources of heat MAX 7 metres 2 indicator Selected temperature scale 9 Programming start up shut down scale indicator 3 Signal transmission 14 POWERFUL button 15 SWING button 16 TIM...

Страница 12: ...herefore refer to the instructions in the chapter Operating from the control panel to turn the appliance on and select the ope rating mode COOL DRY FAN HEAT or SMART and the fan The following section...

Страница 13: ...ess the to confirm The message SLEEP conditions TIMER button appears on the re mote control display and the symbol is displayed on the appliance to indicate that the timer is active SWING FUNCTION Thi...

Страница 14: ...ce The appliance starts up again automatically when the defrosting process is completed If this is displayed contact your local authorised servi ce centre Programming shutdown Press the button The shu...

Страница 15: ...ake the appliance much more economical to run fig 23 Never rest objects of any kind on the air conditioner Do not obstruct the air intake and outlet fig 24 Leave the grilles free Make sure there are n...

Страница 16: ...operation The filters are housed in the intake grille fig 25 Use a vacuum cleaner to remove dust accumulations from the fil ter If it is very dirty immerse in warm water and rinse a number of times T...

Страница 17: ...ven hairdryer etc the air exhaust hose is deta ched from the appliance the technical specification of the appliance is not adequa te for the room in which it is located close doors windows and curtain...

Страница 18: ...absorbed power in air conditioning Refrigerant Cooling capacity LIMIT CONDITIONS Temperature of room in air conditioning 18 35 SIZE OF APPLIANCE width 463 mm height 775 mm depth 382 mm 463 mm 775 mm 3...