background image

 

 

 

 

KALDM40XXXA

 

 
 

USER MANUAL 
 
 
 

 

Содержание KALDM40XXXA

Страница 1: ...KALDM40XXXA USER MANUAL ...

Страница 2: ...difications or performance changes for laser emitters Please keep it out of reach of children and avoid use by any irrelevant personnel It is strictly prohibited to shoot eyes or other parts of body with the laser also avoid shooting laser at any objects with strong reflective surfaces Due to electromagnetic radiation interference to other equipment and devices please don t use the meter in a plan...

Страница 3: ...battery Open the battery door on the back of device and place battery according to correct polarity then close the battery door Only 1 5 V AAA alkaline batteries are to be applied to the meter If device is not being used for a long time please take out the batteries to avoid battery corrosion to meter body Display Screen Keyboard ...

Страница 4: ...then the measured results will show on main display Continuous Measurement Long press key under measuring mode to enter into continuous measurement state and maximum and minimum measurement results in the process of continuous measurement will display on the screen The main display screen indicates the measured result press key to exit continuous measurement state Area Measurement Press key and yo...

Страница 5: ...ly measure the length a of dotted line hypotenuse according to screen prompt Press key to measure the length b of dotted line hypotenuse shown as in the figure Press key to measure the length c of another dotted line hypotenuse shown as in the figure Length x of the solid line right side will be calculated automatically by the meter Under Pythagorean proposition measurement mode length of right si...

Страница 6: ...scope Err 5 Improper Measurement in Pythagorean proposition Re measure and ensure the length of hypotenuse is longer than that of right side Err 6 Memory damage Please contact Kogan Technology specification ITEM Max measured distance 40m Distance measurement precision 2mm Measurement unit options Mm in ft Continuous measurement function Yes Outdoor target reflection board No Area measurement funct...

Страница 7: ...ep the device surface cleaning Wet soft cloth is applied to clean dust but corrosive cleaning liquids are never allowed to be used for meter maintenance Laser output window and its focus lens can be maintained according to maintenance procedures for optical device Packing list Please carefully check instruments and attachments are complete in line with below list No Item Unit QTY 1 Laser Distance ...

Отзывы: