MAINTENANCE
In cases where the water supply is “hard” (meaning that the water contains too
much calcium and magnesium), it can cause water scale on the surface of the
water basin, transducer and inner surface of the water tank.
Scales on the surface of the transducer will reduce the units ability to work
properly.
We recommend that you:
•
Use cold boiled water, or distilled water
•
Clean the transducer and water tank every week
•
Change the water in the tank often to keep it fresh
•
Make sure to remove the water from the water tank and let the unit dry
thoroughly before storing the unit for any period of time
•
Clean the whole unit and makes sure that all parts of the unit are dried
thoroughly before laving the unit unused for a long period of time
•
Do not use any chemicals for cleaning
How to clean the transducer
1. Put 5-10 drops of an ultra-mild cleaning detergent on the surface of the
transducer and wait for 2-5 minutes
2. Brush the scale off the surface
3. Rinse the transducer with clean water
How to clean the basin unit
•
Clean the water basin with a soft cloth and mild detergent if there is scale
in it
•
If the scale is covering the security switch, cover the scale with the
detergent, then clean it with the brush
•
Rinse the basin out with clean water afterwards
TECHNICAL DATA
Model
KAHUM58IONA
Standard output
300ml/H
Water tank volume
5.8 Litres
Noise level
< 35dB (A)
Rated voltage
220-240V
Frequency
50Hz
Rated power input
30W
N.W / G.W
1.6kg / 2.2kg
Disposal
Do not dispose of this product as unsorted municipal waste with your
household garbage. Contact your local council for advice on how to
dispose of electrical equipment.
Содержание KAHUM58IONA
Страница 1: ......