14
Use pointed nose pliers to withdraw the plastic filter.
Clean, put back and secure. These filter should be
checked every 6 months or so, or more often if there
are frequent interruptions to the water supply.
1. Disconnect the machine from
the mains electricity supply and
open the lower cover with a
screwdriver.
2. Place a container under the pump.
Unscrew and remove the filter.
3. Clean the filter carefully.
The filter should be cleaned every 2 months or so, or when there
is fault that the
“E03” is on the screen.
Cleaning the drawer
housing
Use a bottle brush to remove
detergent residues
inside the
drawer housing.
The filter must be put back in place after cleaning.
Important:
If the machine is exposed to temperatures below 0°C, certain precautions
should be taken.
1. Turn off the water tap.
2. Unscrew the inlet hose.
3. Unhook the drain hose from the rear support and position the end of this
hose and that of the inlet hose in a bowl. Run the spin programme.
4. Disconnect the appliance.
5. Screw the inlet hose and reposition the drain hose.
6. When you intend to start the machine up again, make sure that the room
temperature is above 0°C.
Содержание KAGFLWASH9A
Страница 3: ...15 16 13 Electric Diagram 17 10...
Страница 20: ...17 The wiring diagram is used models...