Instructions for using Liquid Gas Cylinders 

 
Liquid gas cylinder systems: 

(Other than propellant gas cylinders and propellant gas cylinder systems) 

 

1.

 

Properties of Liquid gas: 

 

Liquid gas (propane, butane and mixtures thereof) is a highly flammable, colourless 
gas with a perceptible odour. It is heavier than oxygen and is flammable with low 

mixtures of ambient air. Caution: uncontrolled gas can deflagrate or explode. 

 

Liquid gas is pressurised in the cylinder. Protect it from temperatures above 40°C! 
At higher temperatures, especially when exposed to fire, there is a risk of an 

uncontrolled gas leak and even to the cylinder bursting. 

 

2.

 

Conduct in the event of malfunctions and leaks: in the case of fire:

 

 

(e.g. smell of gas, noise of escaping 

gas): 

(in buildings / vehicles) 

additionally: 

Notify the fire 

department! 

Close the cylinder 
valve immediately 

(clockwise)! 

 

Extinguish any naked 

flames! 

 

Contact a specialist! 

Do not smoke! 

 

Do not actuate 

any electrical 
switches! 

 

Do not use the 
telephone! 

Open windows and doors! 

 

Transfer any leaking 

cylinders outside 
immediately! 

 

Evacuate the 
building/vehicle! 

Point out the 

presence of liquid 
gas cylinders! 

 

If possible, remove 

cylinders from any 

area that is 

susceptible to fire or 

cool with water if 
necessary. 

 

3.

 

Operation of Liquid Gas cylinder systems: 

 

Liquid gas cylinder systems should only be installed, commissioned, modified and 
checked by authorised companies. 

 

Liquid gas cylinder systems should only be installed in the commercial sector by 
trained personnel and checked by an appropriately qualified person or, when 

dealing with certain cylinder systems, by a person assigned by the contractor. 

 

The cylinder must be set in an upright position. Cylinders positioned on their side 
pose a threat of inflammation. 

 

Closely observe the instructions provided by in this guide for operation and, if 
necessary, for troubleshooting measures. Prior to the initial operation or after 
making a modification, the operator of a liquid gas cylinder system must be 

assured of its orderly condition through examination and certification by a 
specialised company. 

 
 
 

Содержание Cookmaster CKPTPRGRLA

Страница 1: ...PORTABLE STAND UP PROPANE GRILL CKPTPRGRLA ...

Страница 2: ......

Страница 3: ... a possible danger that can result in damage to property if the specified measures are not observed Operating notes Images Note a useful function or tip Danger Hot surfaces and parts During operation some accessible parts of the barbecue can become very hot particularly those that are close to the fire bowl Possible consequences Severe burns from touching parts near the fire bowl Fire or smoulderi...

Страница 4: ...sing the grill in enclosed areas could lead to gas accumulation from a leak causing an explosion or a carbon monoxide build up which could result in injury or death Do not use in garages sheds or other enclosed areas Protect the gas cylinder and the gas hose from direct sunlight and other sources of heat Take particular care to ensure that the gas hose does not touch any part of the hot barbecue D...

Страница 5: ...gen if the gas concentration can rise sufficiently Safety measures Only use the barbecue outdoors in a well ventilated area and above ground i e not in areas that are below ground level Close the valve on the gas cylinder after each use Never leave the barbecue unattended If the flame is extinguished relight it immediately or cut off the supply from the gas cylinder Before each use make sure that ...

Страница 6: ... x2 Each COMPONENTS ...

Страница 7: ...OVERVIEW Armrest Grill Upper cover Handle Tray Hook up Knob Igniter Limiter Wheel Handle ...

Страница 8: ...Temperature gauge Oil picker Inlet connector Gas cylinder hook Net pocket ...

Страница 9: ...ures are diagrammatical representations of outdoor areas Rectangular areas have been used in these figures the same principles of clearance and ventilation apply to other areas Example 1 Example 2 LOCATION REQUIREMENTS ...

Страница 10: ... ends open Open side at least 25 of total wall area 30 or more in total of the remaining wall area is open and unrestricted Open side at least 25 of total wall area 30 or more in total of the remaining wall area is open and unrestricted ...

Страница 11: ...s for example are very similar and can be easily confused For assembly you will need a medium size screwdriver and a suitable spanner flat spanner or box spanner You will need a flat spanner to connect the gas cylinder Only use tools that are intact and suitable for the job at hand Worn or unsuitable tools will not allow you to tighten the bolts sufficiently but will damage them to the extent that...

Страница 12: ...Step 1 Step 2 ASSEMBLY ...

Страница 13: ...Step 3 Step 4 ...

Страница 14: ...Step 5 Step 6 ...

Страница 15: ... and pans Do not operate the barbecue as a heater Do not use the barbecue to heat materials and substances other than food that is suitable for barbecuing Connecting and Disconnecting the Gas Cylinder 17mm spanner open ended spanner SW 17 Gas cylinder A common camping gas cylinder with a fill weight of 3kg 5kg or 11kg E g grey camping propane gas cylinder Pressure regulator Pre set and approved pr...

Страница 16: ...o flame resistant materials or substances minimum 0 25m The cooker is positioned firmly on a flat sufficiently large surface area It must not be moved during operation All the operation instructions will be according to the instruction of regulator 2 In case of the flow of gas being higher than the capacity of the regulator contact your gas supplier To ensure correct operation of the flow limiting...

Страница 17: ...ctrical switches Do not use the telephone Open windows and doors Transfer any leaking cylinders outside immediately Evacuate the building vehicle Point out the presence of liquid gas cylinders If possible remove cylinders from any area that is susceptible to fire or cool with water if necessary 3 Operation of Liquid Gas cylinder systems Liquid gas cylinder systems should only be installed commissi...

Страница 18: ...r connection must be tested using foaming agents e g soapy water 5 Transport and storage To avoid damaging the valve and to prevent gas leaks full and empty liquid gas cylinders should only be transported and stored with a closed and protected valve wear nut and cap When transporting in vehicles ensure that there is adequate ventilation in the storage area The cylinders must be secured from shifti...

Страница 19: ...airtight Open the top cover and place the grill Rotate the switch to the high fire position and then press the igniter to ignite within 5 seconds Note Do not turn off the switch for a long time otherwise there is a danger of inflammation After ignition you can use the valve body knob to adjust the heat After approximately 3 minutes the temperature will reach 220 C and be suitable for grilling Duri...

Страница 20: ...lement underneath the front panel can be cleaned with a needle All other parts through which gas is passed may only be cleaned by an expert Never dismantle the adjusting element Maintenance Before use checks such as cleaning the appliance and removal of accumulated grease and other cooking residue Routine inspection of the gas hose and regulator and a recommended replacement period of components W...

Страница 21: ...t and assembled visual check Check to ensure that all connections are present and are securely fastened Tighten if necessary Gas System The gas system needs to be checked every time a gas cylinder is connected see chapter Connecting and disconnecting the gas cylinder ...

Страница 22: ...cm Gas System Heat output 8 4MJ h Gas type LPG ULPG Gas cylinder Standard gas cylinder with a fill weight of 3 5 or 11kg Gas pressure 2 75kPa at LPG ULPG Gas hose Approved hose maximum 1 5m Ignition Piezo ignition Flame regulator Infinitely adjustable 0 maximum Nozzle diameter 0 60mm SPECIFICATIONS ...

Страница 23: ...fter use The use of this appliance in an enclosed area can be dangerous and is prohibited For storage and cylinder exchange disconnect the cylinder only Do not disconnect hose from the appliance Always maintain 500mm minimum clearance to combustible materials at the rear and sides of the BBQ Do not use this BBQ under overhead combustible surfaces If applicable Warning When operating this appliance...

Страница 24: ...spection correct if necessary Other gas system blocked The gas system should be cleaned by a specialist Temperature on grill is too low Pre heating time is too short Close lid and set flame regulator to maximum setting Gas outlets on the burner are blocked Remove blockages from burner Popping or bubbling noise Flashback caused by blockages in the burner Close the cylinder valve immediately Wait 3 ...

Страница 25: ......

Страница 26: ...NOTES ...

Страница 27: ......

Страница 28: ......

Страница 29: ...tion We hope that this user guide has given you the assistance needed for a simple set up For the most up to date guide for your product as well as any additional assistance you may require head online to help kogan com ...

Отзывы: