To review an alarm event in memory (memory light on):
Press *3 (the zone or zones violated will blink
displaying any violated zones.). Press 9 previous
alarms (up to three separate alarm events will be held in
memory). Press # to return to normal. The memory light
may stay on until the system is armed the next time.
To review a trouble condition (trouble light on and system beeping every 10
seconds):
Press *2 - a zone light will illuminate indicating the type of trouble
and then the # key to return to normal.
Zone light
1 - Low battery
2 - Loss of AC power
3 - Fuse failure - bell/siren or aux. output
4 - Unsuccessful communication
5 - Fire alarm circuit trouble
6 - Loss of time on internal system clock
To arm the system when someone is staying inside the premises:
(bypassing the interior detection device)
Press *1 (zones to be bypassed - ex: 4 for zone 4, 5 for zone 5)
Press # and the combination
SILENT KNIGHT FIRE ALARM
Silence and Reset Fire Alarm
Before 30 seconds have elapsed:
• Enter 4-digit code to stop siren
• Check which motion detector went into alarm (Solid red light)
• Press *7 and hold the 7 button for 5 seconds
To reset detectors
After 30 seconds have elapsed:
• Press # to stop siren
• Press *7 and hold the 7 button for 5 seconds
• Call 260-422-8823 to cancel the fire dispatch