Koehler K259 Series Скачать руководство пользователя страница 7

K259XX Constant Temperature Water Bath  

Operation and Instruction Manual 

 

K295XX-Manual 

-

3- 

 
WEEE Directive Compliance Statement 

 
 

Background 

The goal of the WEEE Directive is to encourage design of environment-friendly products that increase reuse, recycling 
and other forms of recovery to reduce waste streams and applies to listed Electronic and Electrical Equipment (EEE) 
and  Koehler's  equipment  falls  broadly  into  Appendix  1A;  Section  9  Monitoring  and  Control  Equipment:  Measuring, 
weighing or adjusting appliances for household or as laboratory equipment. 
 
Any associated non-embedded equipment such as Lighting (Saybolt Color) and PCs/Printers also fall under WEEE.  If 
provided  with  an  order  these  ancillary  items  must  be  WEEE  compliant.    For  these  and  other  reasons  (printer 
cartridges are regionalized) the equipment must be supplied through a third party supplier in Europe. 
 
The WEEE  Directive  applies  to  electrical  and  electronic  equipment  falling  under  the  categories  set  out  in  Annex  IA 
provided that the equipment concerned is not part of another type of equipment that does not fall within the scope of 
this Directive. Annex IB contains a list of products which fall under the categories set out in Annex IA.   
 
http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2003:037:0024:0038:en:PDF 
 
We do not qualify for any of the 10 exemption categories. 
http://www.dpa-system.dk/en/WEEE/Products/Exemptions 
 

Professional use 

For  equipment  defined  for  ’professional  use’  local  authorities  have  no  role  to  play.  Producers  and  importers  are 
basically responsible for collection of WEEE recyclables from the professional user and for subsequent management.   
A  separate  statement  is  given  cataloging  the  items  that  require  separation  from  the  equipment  along  with  basic 
information on subsequent processing or recycling prior to disposal of the equipment. 
http://www.dpa-system.dk/en/WEEE/Products/Private-or-professional-use 
 

Responsibility for Registration and Annual Reporting:   

Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to 
make  annual  reports.  Koehler  declares  that  this  responsibility  is  born  by  the  importer  who  is  the  first  level  of  the 
distribution  chain  and  is  subject  to  producer  responsibility.    We  will  communicate  this  in  writing  to  our 
distributor/importers in the EU stating they are responsible to satisfy WEEE registration and reporting requirements in 
the EU states where they conduct sales activities. 
 
It is illegal to market electrical and electronic equipment covered by producer responsibility without being registered. 
 
http://www.dpa-system.dk/en/WEEE/Producers/Whoissubjecttoproducerresponsibility 
 

Product Design 

Koehler's designs allow for complete disassembly to a modular level which usually allows for standard recycling.  A 
qualified  refrigeration  system  technician  must  be  consulted  when  disassembling  and  de-commissioning  any 
equipment with refrigeration systems. 
 
Koehler's scientific testing equipment is robustly designed to function over a long service life and are typically repaired 
many times over the course of years rather than being replaced.  We believe that re-use and refurbishment is the very 
best form of re-cycling.   
 
All batteries must be readily removable not soldered in place. 

 
Recycling instructions 

In the event that replacement becomes necessary, we will include instructions, particularized to each instrument that 
informs the customer of their recycling responsibilities and giving them guidance in doing this. All Koehler equipment 
has  been  placed  on  the  market  since  13th  August  2005  and  so  Koehler  is  defined  as  a  "new WEEE  producer".  As 
such we must provide information on refurbishment, treatment, and re-use. 
 
 

Содержание K259 Series

Страница 1: ... Avenue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumentation Custom Design Manufacturing K259XX Constant Temperature Water Bath ...

Страница 2: ......

Страница 3: ...red in conformance with the applicable standards set forth in this certification Specifications ASTM D1657 GPA 2140 This unit is tested before it leaves the factory to ensure total functionality and compliance to the above specifications and ASTM standards Test and inspection records are on file for verification Jesse Kelly Application Engineer Koehler Instrument Company ...

Страница 4: ......

Страница 5: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 1 ...

Страница 6: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 2 ...

Страница 7: ...nformation on subsequent processing or recycling prior to disposal of the equipment http www dpa system dk en WEEE Products Private or professional use Responsibility for Registration and Annual Reporting Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports Koehler declares that this responsibility is born by...

Страница 8: ...ely collected WEEE Mercury containing components such as switches or backlighting lamps compact fluorescent lamps CFL Batteries Printed circuit boards if the surface of the printed circuit board is greater than 10 square centimeters about 4 sq in Toner cartridges liquid and pasty as well as color toner Chlorofluorocarbons CFC hydrochlorofluorocarbons HCFC or hydrofluorocarbons HFC hydrocarbons HC ...

Страница 9: ...rmation and Warnings 7 3 Getting Started 7 3 1 Packing List 7 3 2 Unpacking 7 3 3 Setup 8 4 Descriptions 9 4 1 Instrument Descriptions 9 4 2 Temperature Controller Operation 11 5 Operation 12 6 Maintenance 12 6 1 Routine Maintenance 12 6 2 Replacement Parts 12 7 Wiring Diagrams 13 7 1 K25900 115V 13 7 2 K25995 230V 50Hz 14 7 3 K25990 230V 60Hz 15 8 Service 16 9 Storage 16 10 Warranty 16 11 Returne...

Страница 10: ...for a full range of accurate and reliable instrumentation as well as support for your laboratory testing programs Please do not hesitate to contact us at any time with your inquiries about equipment tests or technical support 1 2 Recommended Resources and Publications 1 American Society for Testing and Materials ASTM 100 Barr Harbor Drive West Conshohocken Pennsylvania 19428 2959 USA Tel 1 610 832...

Страница 11: ...hemical Reagents Information The use of chemicals and reagents with this equipment may exhibit potential hazards Any use must be familiarized with the possible dangers before use We recommend consulting the Material Data and Safety Sheet MSDS on each chemical reagent for safety information MSDS information can be easily located on the Internet at http siri uvm edu or http www sigma aldrich com 3 G...

Страница 12: ...trument on a firm level surface in an area with adequate environmental control Environmental Conditions The instrument environment must comply with the following conditions for proper setup No Low Dust No direct sunlight Not near heating or AC ventilation ducts No Vibrations Clearance from other instruments Temperature Range 5 to 40 C Elevation to 2000 meters Relative Humidity 80 Filling the Bath ...

Страница 13: ...mometer to verify bath temperature displayed on temperature controller 5 Stirrer Motor To agitate bath medium in order to provide temperature uniformity in the apparatus 6 Temperature Measurement Probe Measures direct temperature of bath and communicates with temperature controller for display Figure 2 Instrument Descriptions_Front Panel 7 Line Switch For powered on entire unit Temperature control...

Страница 14: ... emptying bath medium to appropriate receptacle 16 Bath Outlet Connect insulated tubing from mechanically refrigerated chiller inlet Figure 6 Item 19 Figure 4 Instrument Descriptions_ Back_115V_230V 60Hz 17 Chiller Power Receptacle_115V For connecting mechanically refrigerated chiller Figure 1 Item 3 power cord to constant temperature bath Figure 1 Item 1 NOTE Plug type for 115V 60Hz and 230V 60Hz...

Страница 15: ... to fully equilibrate before proceeding with any testing Temperature Calibration This routine allows the digital temperature controller to be calibrated to a certified thermometer a Use a certified calibrated measuring device to acquire the temperature Calculate the difference between the measuring device and the Process value displayed on the controller b Press the program key two times until PCt...

Страница 16: ... Allow time for the bath temperature to equilibrate 7 Proceed with performing the test according to the test methods prescribed in Section 1 2 of this document 6 Maintenance WARNING Disconnect power to the unit before servicing to avoid exposure to high voltages and or temperatures which may result in personal injury or death If you have any questions about maintaining your equipment please do not...

Страница 17: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 13 7 Wiring Diagrams 7 1 K25900 115V ...

Страница 18: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 14 7 2 K25995 230V 50Hz ...

Страница 19: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 15 7 3 K25990 230V 60Hz ...

Страница 20: ...he return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or replacement of the product In no event shall the cost of the purchaser s remedy exceed the purchase price nor shall Koehler Instrument Company be liable for any special indirect incidental conseq...

Страница 21: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 17 Notes ...

Страница 22: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 18 Notes ...

Отзывы: