Koehler K259 Series Скачать руководство пользователя страница 1

 

Operation and Instruction Manual 

 

REV C  

 

 
 
 
 

Koehler Instrument Company, Inc. 

1595 Sycamore Avenue • Bohemia, New York 11716-1796 • USA 

Toll Free: 1-800-878-9070 

(US only) • Tel: +1 631 589 3800 • Fax: +1 631 589 3815 

http://www.koehlerinstrument.com • e-mail: [email protected] 

Petroleum Testing & Analysis Instrumentation • Custom Design & Manufacturing 

 

 
 
 
 
 
 

 
 

 

 
 
 

K259XX 

Constant Temperature Water Bath

Содержание K259 Series

Страница 1: ... Avenue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumentation Custom Design Manufacturing K259XX Constant Temperature Water Bath ...

Страница 2: ......

Страница 3: ...red in conformance with the applicable standards set forth in this certification Specifications ASTM D1657 GPA 2140 This unit is tested before it leaves the factory to ensure total functionality and compliance to the above specifications and ASTM standards Test and inspection records are on file for verification Jesse Kelly Application Engineer Koehler Instrument Company ...

Страница 4: ......

Страница 5: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 1 ...

Страница 6: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 2 ...

Страница 7: ...nformation on subsequent processing or recycling prior to disposal of the equipment http www dpa system dk en WEEE Products Private or professional use Responsibility for Registration and Annual Reporting Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports Koehler declares that this responsibility is born by...

Страница 8: ...ely collected WEEE Mercury containing components such as switches or backlighting lamps compact fluorescent lamps CFL Batteries Printed circuit boards if the surface of the printed circuit board is greater than 10 square centimeters about 4 sq in Toner cartridges liquid and pasty as well as color toner Chlorofluorocarbons CFC hydrochlorofluorocarbons HCFC or hydrofluorocarbons HFC hydrocarbons HC ...

Страница 9: ...rmation and Warnings 7 3 Getting Started 7 3 1 Packing List 7 3 2 Unpacking 7 3 3 Setup 8 4 Descriptions 9 4 1 Instrument Descriptions 9 4 2 Temperature Controller Operation 11 5 Operation 12 6 Maintenance 12 6 1 Routine Maintenance 12 6 2 Replacement Parts 12 7 Wiring Diagrams 13 7 1 K25900 115V 13 7 2 K25995 230V 50Hz 14 7 3 K25990 230V 60Hz 15 8 Service 16 9 Storage 16 10 Warranty 16 11 Returne...

Страница 10: ...for a full range of accurate and reliable instrumentation as well as support for your laboratory testing programs Please do not hesitate to contact us at any time with your inquiries about equipment tests or technical support 1 2 Recommended Resources and Publications 1 American Society for Testing and Materials ASTM 100 Barr Harbor Drive West Conshohocken Pennsylvania 19428 2959 USA Tel 1 610 832...

Страница 11: ...hemical Reagents Information The use of chemicals and reagents with this equipment may exhibit potential hazards Any use must be familiarized with the possible dangers before use We recommend consulting the Material Data and Safety Sheet MSDS on each chemical reagent for safety information MSDS information can be easily located on the Internet at http siri uvm edu or http www sigma aldrich com 3 G...

Страница 12: ...trument on a firm level surface in an area with adequate environmental control Environmental Conditions The instrument environment must comply with the following conditions for proper setup No Low Dust No direct sunlight Not near heating or AC ventilation ducts No Vibrations Clearance from other instruments Temperature Range 5 to 40 C Elevation to 2000 meters Relative Humidity 80 Filling the Bath ...

Страница 13: ...mometer to verify bath temperature displayed on temperature controller 5 Stirrer Motor To agitate bath medium in order to provide temperature uniformity in the apparatus 6 Temperature Measurement Probe Measures direct temperature of bath and communicates with temperature controller for display Figure 2 Instrument Descriptions_Front Panel 7 Line Switch For powered on entire unit Temperature control...

Страница 14: ... emptying bath medium to appropriate receptacle 16 Bath Outlet Connect insulated tubing from mechanically refrigerated chiller inlet Figure 6 Item 19 Figure 4 Instrument Descriptions_ Back_115V_230V 60Hz 17 Chiller Power Receptacle_115V For connecting mechanically refrigerated chiller Figure 1 Item 3 power cord to constant temperature bath Figure 1 Item 1 NOTE Plug type for 115V 60Hz and 230V 60Hz...

Страница 15: ... to fully equilibrate before proceeding with any testing Temperature Calibration This routine allows the digital temperature controller to be calibrated to a certified thermometer a Use a certified calibrated measuring device to acquire the temperature Calculate the difference between the measuring device and the Process value displayed on the controller b Press the program key two times until PCt...

Страница 16: ... Allow time for the bath temperature to equilibrate 7 Proceed with performing the test according to the test methods prescribed in Section 1 2 of this document 6 Maintenance WARNING Disconnect power to the unit before servicing to avoid exposure to high voltages and or temperatures which may result in personal injury or death If you have any questions about maintaining your equipment please do not...

Страница 17: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 13 7 Wiring Diagrams 7 1 K25900 115V ...

Страница 18: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 14 7 2 K25995 230V 50Hz ...

Страница 19: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 15 7 3 K25990 230V 60Hz ...

Страница 20: ...he return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or replacement of the product In no event shall the cost of the purchaser s remedy exceed the purchase price nor shall Koehler Instrument Company be liable for any special indirect incidental conseq...

Страница 21: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 17 Notes ...

Страница 22: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 18 Notes ...