7. THE  ALARM  SYSTEM  SETUP.

Default  factory  settings  and  available  settings  are  listed  in  Table  2  of  chapter  7.4.  If  default  settings  are  not  suitable  there  are  2 ways  to  change  

them.

7.1. MANUAL  SETUP:

a)

turn  the  override  mode  ON  by  entering  the  PIN

;

b)

the  system  LED  will  start  frequently  flashing;

c) within   8 minutes   of   the   override   mode   being   turned   ON,   in   the   same   way   as   before   entering   the   PIN,   enter   the   FN   number   of   the   function   you   

want  to  change;

d) if   the   correct   FN   number   was   entered,   the   system   indicates   the   current   SN   value   by   5 separate   series   of   direction   indicator   flashes   (with   a   pause 

of   2 seconds   between   the   series),   the   number   of   flashes   in   each   series   corresponds   to   current   SN   value;

e) the   assigned   control   time   is   extended   for   another   8 minutes.   No   flash   of   direction   indicators   means   either   incorrect   FN   entry   or   the   8 minute   

control  time  has  elapsed;

f) if   the   FN   has   not   been   entered   due   to   the   8 minute   control   time   being   elapsed,   repeat   the   steps   starting   from   a);

if  the  FN  has  not  been  entered  due  to  a  mistake,  wait  until  the  system  LED  starts  flashing  frequently  and  re-enter  the  FN  code;.

g) if  the  SN  does  not  mach  your  needs  you  can  change  it.  To  change  it  do  the  following:  when  the  system  indicates  the  current  SN  value  by  5 

separate  series  of  flashes  press  and  hold  down  the  override  button  or  turn  ON  the  ignition.  The  direction  indicators  start  to  flash  by  single  
flashes  every  3 seconds.  When  the  number  of  flashes  corresponds  to  the  necessary  SN  value  (wait  a  second  after  the  last  flash)  release  the  
override  button  or  turn  OFF  the  ignition.  The  system  confirms  a  new  SN  value  entry  by  a  long  siren  beep  (0.5 second)  and  indicates  a  new  SN  
value   by   5 separate   series   of   direction   indicator   flashes.   The   control   time   is   extended   for   another   8 minutes;

The  Manual  Setup  sequence  summary  is  listed  in  Table 1.

Table 1

7.2. THE  ALARM  SYSTEM  SETUP  BY  COMPUTER.

For  professional  fitting  it's  recommended  that  the  PULSE-LATCHER  device,  a  PC  and  the  'CAdmin'  software  for  an  alarm  system  setup  are  

used.  This  way  it's  possible  to  speed  up  the  installation,  to  update  the  alarm  system  database  with  a  new  car's  data  and  possible  to  store  the  records  
about  changed  settings  of  each  installation.  To  update  an  alarm  system  with  the  help  of  a  PC  do  the  following  steps:

a) check

  the  'CAdmin'  software  is  present  on  your  PC  or  download  it  from  www.kodinis.lt,  http://www.kodinis.lt/en/products/Car-Alarm-System-

Accessories

;

b) connect

  an  alarm  system  to  the  computer  by  using  the  PULSE-

LATCHER   device   as   seen   in   diagram   (see   chapter. 4);

c) t

urn  ON  the  car  alarm  override  mode  by  entering  the  PIN

;

d) w

ithin   8 minutes   start   the   'CAdmin' software   with   the   PULSE-

LATCHER  device  connected

;

e) create

  a  new  installer  account  or  login  with  an  existing  one

;

f)

click  

on   the   “Clients   DB”   icon   (see   Fig. 3-A)

;

g) create  

an  account  for  the  new  client  by  clicking  on  “New  client”  

button;

h)

Fill  up  the  fields  in  the  “Client  data”  form,  select  the  correct  type  of  
alarm  system  and  serial  number  according  to  the  information  sticker  
(see   Fig. 1)   and   click   on   “OK”;

i)

m

ake  a  double  click  on  this  then  a  newly  created  client  record  and  

table   with   the   alarm   system   default   settings   will   appear   (see   Fig. 3-B);

j)

t

o  make  a  settings  change  click  on  the  “Change  settings”  icon  (see  

Fig. 3-C)   and   from   the   options   displayed   click   on   the   options   you   
want  (by  clicking  on  their  selection  circles).  When  they  are  filled  in  
you   have   chosen   that   option   (see   Fig. 3-D);

k) w

hen  all  the  changes  are  made  click  on  the  “Change  settings”  icon  once  again  to  disable  changing  opportunity  and  click  on  the  “Update  CA  

Settings”  icon  (see  Fig. 3-E)  to  start  the  Car  Alarm  settings  update  procedure;

l)

i

f  the  alarm  system  setup  mode  is  left  idle  for  more  than  8 minutes  (the  control  time)  the  system  will  automatically  exit  the  setup  mode.  To  go  

back  into  the  setup  mode  you  must  re-enter  the  PIN

.

7.3. THE  ALARM  SYSTEM  LEARNING.

For  adaptation  of  vehicle  alarm  system  the  Central  Lock  action  sequence  can  be  used  

computer  learning

,  

automatic  learning

  or  

manual  

learning:

Computer  learning

  is  advanced,  but  it  is  much  more  precise  and  reliable.

=

enter

 

 the   PIN   code   if   control   time   is   elapsed;

=

connect  

'

GN6Ib

'

  to  PC  using  the  „PULSE-LATCHER”  device;

=

start  

'

Cadmin

'

  software  and  press  the  button  

'

OSC  

GN6IA

'

  on  software  window;

=

following  the  software  instructions  read  out  the  sequences  of  pulses  are  generated  on  '

GN6Ib

'  inputs  during  the  Central  Lock  is  

locked  and  unlocked;

=

read  pulses  will  be  displayed  on  the  computer  display.  According  with  these  pulses  adjust  the  pulse  identification  parameters

;

=

a

fter  adjustment  send  the  data  to  the  alarm  system;

=

these  pulse  parameters  of  the  specific  vehicle  may  be  stored  in  a  file,  so  in  case  installation  of  '

GN6Ib

'  in  vehicle  with  the  same  

Central  Locking  System  it  will  be  no  need  to  read  out  the  pulses.  It  will  be  enough  to  open  stored  file  and  send  the  data  to  '

GN6Ib

';

Automatic  learning

  is  more  simple  (no  computer  is  needed),  but  less  precise  and  reliable  because  the  installer  has  no  chance  to  observe  

the  processes  on  the  alarm  system  inputs.  The  automatic  learning  does  not  learn  the  pulses  on  input  'CONDITION2'.

=

if  FN

=54,  SN=4  is  selected,  

the  system  switches  to  automatic  learning  mode.  The  system  siren  emits  the  series  of  single  or  double 

CONDITION

ACTION

CONTROL

TIME

DIRECTION

INDICATORS

SIREN

SYSTEM

LED

-

 / door  opened

PIN  ENTRY

-

Long  flashes / 

double  flashes

PIN  entered

FN

ENTRY

FN  is  entered,  the  override  

button  is  not  pressed / 

ignition  is  turned  OFF

SN

CHECK

FN  is  entered,  the  override  button

is  pressed / ignition  is  turned  ON

SN

CHANGE

8  minutes

Frequent  flashes

-

-

-

-

5 series  of  flashes  (2 second  pause

between  series)  number  of  flashes
in  series  

corresponds  to  SN  value

-

FN=11

ENTRY

Long  beep  confirms

new  SN  value

8  minutes

Single  flashes

every  3 seconds

8  minutes

Long  flashes / 

double  flashes

Setup

is  over

Long  flashes / 

double  flashes

8  minutes

Frequent  flashes

-

-

-

A

F

C

E

B

Fig. 3.  'Cadmin'  software.  Window  of  settings.

D

Содержание GN6Ib.U

Страница 1: ...temporarily disabled therefore the following occurs as a result the device will not immobilize the engine the car will not become alarmed the system s LED flashes frequently The override mode can be...

Страница 2: ...rey Grey Orange Orange Green Green Blue Blue CONDITION2 F 4 1 N 5 SN 1 V o 2 f r ir cti n nd cat d e o i i ors 7 7 DOOR S FN32 S 2 N S DOOR F N N32 S 1 Electronic siren FN 65 SN 5 PULSE LATCHER 3 2 1...

Страница 3: ...VD1 VD1 VD3 VD3 VD2 VD2 VD4 R1 3K 10K R1 3K 10K R2 3K 10K Door lock contact for locking Door lock contact for locking Door lock contact for unlocking Central lock switch contact in passenger compartme...

Страница 4: ...ing on New client button h Fill up the fields in the Client data form select the correct type of alarm system and serial number according to the information sticker see Fig 1 and click on OK i make a...

Страница 5: ...tion indicators flash starts the siren sounding for at least 10 seconds and stops alarming only when the ignition is turned OFF If the ignition is turned OFF the system immobilizes the engine and auto...

Страница 6: ...out time of the pulses pre set by the system during automatic learning process as a disarming pulses is limited to 5 seconds must be set before automatic learning procedure Read out time of the pulses...

Страница 7: ...ction ALARM SYSTEM OPERATION WHEN BUIT IN ULTRASONIC SENSOR IS TRIGGERED FOR GN6Ib U GN6Ib UPS ONLY Function ALARM SYSTEM OPERATION WHEN BUILT IN TILT SENSOR IS TRIGGERED FOR GN6Ib UPS ONLY The direct...

Страница 8: ...number of flashes 1flash means the alarm was triggered by built in shock or ultrasonic sensor 2flashes mean the alarm was triggered by opening door engine bonnet or luggage compartment 5flashes mean...

Отзывы: