Before starting, read and understand all safety instructions 

included in this manual 

 

Starting Operation 

 

1.

 

Locate the generator on flat terrain, away from water hazards and/or 
flammable liquids.  Check all electrical cords for cracked or exposed 
wires.  Replace if necessary. 

 

2.

 

Follow the engine starting procedures contained in the Honda Engine 
Owners Manual.   Once started, allow the engine to reach operational 
temperature for a few minutes without applying load on the alternator. 

 

3.

 

Make sure that the appliance is switched off before connecting it to the 
generator.   Do not move the generator while it is running.  

 

4.

 

Be sure to ground the generator if the connected appliance is grounded.  

Failure to ground the generator may lead to electrical shock.

 

 

5.

 

If the generator is overloaded, or short-circuited, a breaker switch is  
automatically tripped, preventing electrical current from being supplied 
to the appliance.  Check the appliance to ensure that the start-up wattage 
requirements does not exceed the capacity of the generator. Press the 
reset button. 

 
 

Shutdown Procedure 

 
1.

 

Turn off the power switch of the electrical appliance and disconnect from 
the generator. 

 

2.

 

Allow the engine to cool down for approximately 3 minutes at no-load. 

 

3.

 

Refer to the Honda Engine Owner’s Manual for engine shutdown 
procedures. 

 

4.

 

Remove any mud, dirt or condensation from the generator.  Store in a dry 
place. 

 
 

Maintenance and Storage 

(Please refer to the Honda Engine Owner’s Manual) 
 
Periodic inspection and maintenance of the Honda engine are essential if a high 
level performance is to be maintained.  Regular maintenance will also ensure a 
long service life.  The required service intervals and kind of maintenance to be 
performed are described and outlined in the Honda Engine Owner’s Manual.   
 

Содержание SGA2300GC

Страница 1: ...SGA2300GC Gasoline Powered 2300 Watt Portable Generator Operating Instructions and Parts Manual Printed in Canada Man SGA2300GC 00 John Brooks Company Limited Mississauga Ontario L5N 7K5 1 ...

Страница 2: ...airs to the product or affect replacement of defective parts which will be done at no charge within a reasonable time after receipt of the product Units or parts should be returned at the customer s expense to the nearest JOHN BROOKS location or Authorized Service Centre Pack unit in a strong carton and pad tightly to avoid damage Damage in transit is not covered by warranty Include original purch...

Страница 3: ...rush replacement and increases the service life of the generator Ideally suited for camping boating farm household workshop and construction usage the SGA2300GC is perfect when remote or back up power is required In order to determine the power requirements of the equipment you wish to operate please consult the chart below The ratings indicated are approximations only You should always check the ...

Страница 4: ...the generator near flammable products 8 Do not operate the generator in areas with poor ventilation The exhaust fumes contain carbon monoxide a poisonous odorless invisible gas Prolonged exposure can lead to unconsciousness and death 9 Do not connect the generator to a commercial power line 10 Do not operate any generator with missing or broken parts Contact your dealer for replacement parts 11 Th...

Страница 5: ...r short circuited a breaker switch is automatically tripped preventing electrical current from being supplied to the appliance Check the appliance to ensure that the start up wattage requirements does not exceed the capacity of the generator Press the reset button Shutdown Procedure 1 Turn off the power switch of the electrical appliance and disconnect from the generator 2 Allow the engine to cool...

Страница 6: ...f problems with generator units are with the engine Please refer to the Honda Engine Owner s Manual if engine problems arise If the problem persists contact your local Honda Equipment Dealer Trouble Cause Remedy Engine fails to start Low fuel level Fuel strainer cock closed Spark plug loose or dirty Refill the fuel take making sure not to overfill Open fuel strainer cock 1 If loose push spark plug...

Страница 7: ...d Housing 0390302217 8 Stator 9 Drive end Housing 0391700138 14 Rotor 15 Fan 0392000030 19 Bearing 6202 2RS1 0390302530 25 Rectifier Bridge 0391400601 26 Diode 0390400012 27 Varistor 0392000256 28 Cover Bolt 29 Stud 65 Capacitor 67 Enclosing Band 68 Flange 107 Rubber Cap 0391802005 103 Socket 109 Breaker 124 Rubber Cap 0390200749 7 ...

Отзывы: