KDCF30
KDCF30
CF30-S2 SOFTWARE DRIVERS
The “S2” option adds two additional dedicated serial ports to the docking
station. It is necessary to install software drivers to access these ports. The
drivers are available to download on our web site at all times.
AUTO SHUTDOWN SWITCH SETTINGS
TIMER SETTING
DIP 1
DIP 2
DIP 3
RESULT
ON
ON
ON
DISABLE
ON
ON
OFF
30 MIN
ON
OFF
ON
60 MIN
ON
OFF
OFF
90 MIN
OFF
ON
ON
120 MIN*
OFF
ON
OFF
200 MIN
OFF
OFF
ON
300 MIN
OFF
OFF
OFF
CONSTANT ON**
LOW VOLTAGE MONITORING
DIP 4
RESULT
ON
ENABLED*
OFF
DISABLED
* FACTORY DEFAULT
** The “Constant ON” setting will turn the docking station ON with
the ignition switch, but will never turn it off. This was designed
for Fire Departments and emergency response vehicles who wish
to leave the docking station ON all the time and retain the low
voltage monitoring feature.
PORT DIAGRAM
The following is a diagram of the port layout located on the
bottom of the docking station.
OUTPUT TRIGGER WIRING DIAGRAM
The output trigger on this docking station is to be used in conjunction with
a relay. The output trigger functions as a negative ground with a 400mA
maximum load. See block diagrams.
MULTIPLE DEVICE SCHEMATIC [Block Diag. 2]
SINGLE DEVICE SCHEMATIC [Block Diag. 2]