MDC-5000 Series
Chapter 3 Other Setting
0093153005-00
3-1
Chapter 3 Other Setting
3.1
VECTOR REL/TRUE
1
Press MENU key to display
“Menu”.
2
[TARGET] => [VECT] => [TRUE/REL] => select [TRUE] or [REL], and press ENT key.
3.2
VECTOR TIME
1
Press MENU key to display
“Menu”.
2
[TARGET] => [VECT] => [TIME] => select [OFF], [30 sec], [1 min], [3 min], [6 min], [12 min],
[30 min] or [60 min], and press ENT key.
3.3
CPA/TCPA Alarm
The menu of
“[TARGET] => [CPA/TCPA]” sets the alarm function ON or OFF.
To avoid collision, it sets up LIMIT CPA and LIMIT TCPA.
1
Press MENU key to display
“Menu”.
2
[TARGET] => [CPA] => change the setting value with joystick, and press ENT key.
CPA setting value: 0.0 to 19.9 NM
3
[TARGET] => [TCPA] => change the setting value with joystick, and press ENT key.
TCPA setting value: 1.0 to 63.0 min