www.bbhscanners.com
84 of 142
Use the blower accessory to blow off any dirt from the double feed detector (A) and double feed
detector (B).
Close the ADF door.
•
When you close the ADF door, close it securely until the door is locked. Do not slam the ADF
door.
Cleaning the Starting, Skew and Ending Sensors
Preparation:
Locate the blower accessory and remove the brush from the blower.
Press the power button to the OFF position.
Pull the exit door release lever to open the exit door.
4
Double feed
detector (A)
Double feed detector (B)
5
Blower accessory
Blower
Sensor or detector
1
2
Reflector sheet for
ending sensor
Reflector sheet for
skew sensor (right)