HOW TO SET A PARAMETER
In this section it is explained with every PARAMETER, how to use the CES SERVICE
SOFTWARE. The first line tells always what should be performed. In the next lines it is
explained how to reach this goal. These additional explanations are printed
italic
and can be
skipped if you are experienced with the CES SERVICE SOFTWARE.
EXAMPLE:
1
.
Change PARAMETER XYZ
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select PARAMETER XYZ
Key in the new value.................................................................................. press ENTER
Select STORE PARAMETER .................................................................. press ENTER
NOTE
It is very important to STORE PARAMETERS. If this is not done only the DISPLAY of the LAP
TOP shows the new values. However they are not transferred into the battery backed up
memory of the ML2000 / ML2000P.
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER
MINILOADER TYPE
This PARAMETER is needed to select ML2000 or ML2000 P.
00H:
ML2000
01H:
ML2000 P
CASSETTE UNIT
1. VACUUM OFF TIME
PURPOSE:
To turn off the CASSETTE SUCKERS VACUUM at the correct time.
The CASSETTE SUCKER BAR picks up the exposed FILMS from the CASSETTE. As soon
as SENSOR B20 VACUUM OFF detects the LEADING EDGE of the FILM, the VACUUM OFF
PARAMETER
SM 3477
6/1997
4-2
KODAK AG, Stuttgart
Содержание Miniloader 2000 P
Страница 6: ...TABLE OF CONTENTS SM 3477 6 1997 IV KODAK AG Stuttgart ...
Страница 10: ...TOOLS SM 3477 4 1997 1 2 KODAK AG Stuttgart ...
Страница 46: ...REPLACEMENTS SM 3477 6 97 2 36 KODAK AG Stuttgart ...
Страница 104: ...PARAMETER SM 3477 6 1997 4 10 KODAK AG Stuttgart ...
Страница 112: ......