Kodak 5219 Скачать руководство пользователя страница 4

4

KODAK VISION3 500T Color Negative Film 5219 / 7219 / SO-219 

 H-1-5219t

Modulation-Transfer Function Curves

This graph shows a measure of the visual sharpness of 

this film. The x-axis, "Spatial Frequency," refers to the 
number of sine waves per millimeter that can be resolved. 
The y-axis, "Response," corresponds to film sharpness. 
The longer and flatter the line, the more sine waves per 
millimeter that can be resolved with a high degree of 
sharpness—and, the sharper the film.

Diffuse rms Granularity Curves

To find the rms Granularity value for a given density, find 

the density on the left vertical scale and follow horizontally 
to the characteristic curve and then go vertically (up or 
down) to the granularity curve. At that point, follow 
horizontally to the Granularity Sigma D scale on the right. 
Read the number and multiply by 1000 for the rms value. 

Note: 

This curve represents granularity based on modified 

measuring techniques.

4

4. Sensitometric and Diffuse RMS Granularity curves are produced on 

different equipment.  A slight variation in curve shape may be noticed.

Exposure:

 3200K Tungsten

Process:

 ECN-2

Densitometry:

 Status M

100

1

2

3 4 5

10

20

50

200

600

SPATIAL FREQUENCY (cycles/mm)

RESPONSE (%)

10

1

2

5

3

7

30

20

100

70
50

200

R

G

B

TI2647B

Process:

 ECN-2

0.02

0.03

0.04

0.05

0.10

0.005

0.004
0.003

0.002

0.01

0.006

Blue Density
Green Density
Red Density
Blue Grain
Green Grain
Red Grain

GRANULARITY SIGMA D 

.001

R

G

R

G

B

B

4.0

5.0

2.0

0.0

1.0

3.0

2.0

1.0

DENSITY

0.0

LOG RELATIVE EXPOSURE

3.0

TI2647C

Spectral Sensitivity Curves

These curves depict the sensitivity of this film to the 

spectrum of light. They are useful for determining, 
modifying, and optimizing exposure for blue- and 
green-screen special-effects work.

Spectral Dye Density Curves

These curves depict the spectral absorptions of the dyes 

formed when the film is processed. They are useful for 
adjusting or optimizing any device that scans or prints the 
film.

Note: 

Cyan, Magenta, and Yellow Dye Curves are 

peak-normalized.

Effective Exposure:

 1/25 sec

Process:

 ECN-2

Densitometry:

 Status M

Densitry:

 0.2>D-min

700

750

650

600

550

500

450

400

350

300

250

*Sensitivity = reciprocal of exposure (erg/cm  ) required

to produce specified density

WAVELENGTH (nm)

2

LOG SENSITIVITY

0.0

*

1.0

2.0

3.0

4.0

Yellow-

Forming

Layer

Magenta-

Forming

Layer

Cyan-

Forming

Layer

TI2647D

Process:

 ECN-2; D-mins subtracted

-0.2

0.2

0.0

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

400

450

500

550

600

650

700

750

800

Yellow

Magenta

Cyan

Minimum Density

Midscale Neutral

DIFFUSE SPECTRAL DENSITY

WAVELENGTH (nm)

TI2647E

Содержание 5219

Страница 1: ...5 percent This relates to optimized film handling rather than preservation static dust attraction and curl related problems are generally minimized at the higher relative humidity After usage the film should be returned to the appropriate medium or long term storage conditions as soon as possible For more information about medium and long term storage seeANSI PIMAIT9 11 1998 SMPTE RP131 2002 and K...

Страница 2: ...m supplied by Eastman Kodak Company 2 The LAD Control Film provides both objective sensitometric control and subjective verification of the duplicating procedures used by the laboratory In the LAD Control Method 3 the electronic color analyzer used for color timing is set up with the LAD Control Film to produce a gray video display of the LAD patch corresponding to 1 0 neutral density gray on the ...

Страница 3: ...dulation Transfer Function Curve rms Granularity Refer to curve Read with a microdensitometer red green blue using a 48 micrometer aperture The perception of the graininess of any film is highly dependent on scene content complexity color and density Other factors such as film age processing exposure conditions and telecine transfer may also have significant effects CURVES Sensitometric Curves The...

Страница 4: ...FREQUENCY cycles mm RESPONSE 10 1 2 5 3 7 30 20 100 70 50 200 R G B TI2647B Process ECN 2 0 02 0 03 0 04 0 05 0 10 0 005 0 004 0 003 0 002 0 01 0 006 Blue Density Green Density Red Density Blue Grain Green Grain Red Grain GRANULARITY SIGMA D 001 R G R G B B 4 0 5 0 2 0 0 0 1 0 3 0 2 0 1 0 DENSITY 0 0 LOG RELATIVE EXPOSURE 3 0 TI2647C Spectral Sensitivity Curves These curves depict the sensitivity ...

Страница 5: ...22 400 T 2R 7605 2R 2994 16 mm SP578 122 400 S 153 400 ft spool 2R 7605 2R 2994 16 mm SP445 61 200 A Winding A 1R 7620 1R 3000 16 mm SP455 30 100 R 90 100 ft spool Winding B 1R 7605 1R 2994 16 mm SP457 122 400 T Winding B 1R 7605 1R 2994 16 mm SP458 244 800 Z Winding B 1R 7605 1R 2994 16 mm SP462N 15 50 R 236 50 ft spool 2R 7605 2R 3000 S8 mm SP464 15 50 Super 8 cartridge Films Film for the Cinema...

Страница 6: ...SIA PACIFIC REGION AUSTRALIA Melbourne Kodak Australasia Pty Ltd 181 Victoria Parade Collingwood Victoria 3066 Australia Tel 61 3 8417 8520 Fax 61 3 8417 8011 E mail mpfilmoz kodak com www kodak com au go motion Sydney Level 4 68 72 Waterloo Road North Ryde NSW2113 Australia Tel 61 2 9870 4378 Fax 61 2 9870 4292 CHINA Peoples Republic Kodak China Limited Beijing Liaison Office 9th Floor Beijing Ke...

Отзывы: