Kodak 1802230 - I750 - Document Scanner Скачать руководство пользователя страница 69

A-61500   May 2010

6-13

i700 Series Scanners 
Message listing

Following is an alphabetic list of messages and corrective actions you 
can take if one of the following messages is encountered

Messages

ID#

Operator Message

Background accessory changed 
while powered up

381

The Background Accessory was changed while the scanner was 
powered on. 

• Turn the power off to the scanner, wait a few seconds and 

power the scanner back on.

• If you get this message and you did not change the 

Background Accessory, clean the scanner.

Cable unplugged

319

Some device on the FireWire bus was unplugged/plugged in. 

• Check that all FireWire connectors are securely fastened.

Calibration failed

106, 331  • Clean the imaging guides. See Chapter 5, 

Maintenance

 for 

procedures. 

• Try to calibrate the scanner again. Be sure you are using the 

correct calibration target. See Chapter 3, “Calibrating the 
scanner”. 

• The calibration target is too small. A 12- x 12-inch calibration 

target is required for image calibration. 

• Calibration target is too narrow.
• If the problem persists, call Service.

Calibration succeeded 

105, 342

Informational message.

 The scanner has been successfully 

calibrated.

Call Service

Many ID 

numbers

A condition was detected that may require repair.

• Turn the power off to the scanner, wait a few seconds and 

power the scanner back on.

• If the problem persists, call Service and provide the ID number 

of the error.

Cannot calibrate with white 
background

184

The White Background Accessory is installed in the scanner 
while the scanner is trying the calibrate.

Remove the White Background Accessory before calibrating the 
scanner.

Check document preparation

123, 135, 

81

• The gap between your documents is too small.
• Make sure the leading edges of the documents are aligned. 

See Chapter 3, “Document preparation” for more information.

• Check the condition of your feed module and separation roller 

tires and your pre-separation pad. Clean and replace if 
necessary.

Check imaging guides and lamps

149, 178, 

139

• Verify that the imaging guides are installed correctly. See 

Chapter 5, 

Maintenance

.

• Clean both sides of the imaging guides and lower glass plate 

between the lamps.

• Check that the white patch on the imaging guides is clean and 

in good condition.

• If the problem persists, call Service.

Clean lower imaging guide

294

The lower imaging guide is dirty or there may be a small piece of 
paper in the imaging guide area. 

• Clean the imaging guides. See Chapter 5, 

Maintenance

 for 

procedures. 

Содержание 1802230 - I750 - Document Scanner

Страница 1: ...CD d installation Benutzerhandb cher auf der Installations CD Guida dell utente sul CD di installazione Gu as de usuario incluidas en el CD de instalaci n Guias do usu rio no CD de instala o Gebruike...

Страница 2: ...stalling the IEEE 1394 card in the host computer 2 2 Installing the Kodak Driver software 2 2 Installing the FireWire cable 2 2 Attaching the power cord 2 3 Powering up the host computer 2 3 Scanner c...

Страница 3: ...5 Maintenance 5 1 Cleaning frequency chart 5 2 Cleaning tools and materials 5 2 Supplies and accessories 5 3 Ordering parts 5 3 Cleaning procedures 5 4 Replacement procedures 5 12 Replacing the feed m...

Страница 4: ...anning document feeder and output tray adjustments scanner calibration and how to scan documents Chapter 4 Using the Enhanced Printer provides procedures for using and maintaining the Enhanced Printer...

Страница 5: ...Kodak i750 Scanner is a desktop duplex color scanner with an automatic document feeder that runs at 115 pages per minute which includes an enhanced printer Kodak i780 Scanner is a desktop duplex colo...

Страница 6: ...bilities Electronic red green and blue color dropout Output resolutions include black and white 200 240 300 400 Color 100 150 200 240 300 Grayscale 100 150 200 240 300 NOTE Different scanning resoluti...

Страница 7: ...roughput The following speeds pages per minute are for color grayscale and black and white output Resolution dpi Landscape Letter Portrait Letter Color Gray B W i610 i620 i640 i660 i610 i620 i640 i660...

Страница 8: ...essory Ultra Lightweight Feeder Accessory Instructions A 61190 when you purchase the Ultra Lightweight Feeder Accessory these instructions are included and provide a description of how to use the Ultr...

Страница 9: ...iderations For disposal or recycling information please contact your local authorities or in the USA visit the Electronics Industry Alliance website www eiae org The product packaging is recyclable Th...

Страница 10: ...nsverordnung 3 GSGV Der arbeitsplatzbezogene Emissionswert betr gt 70 db A Machine Noise Information Ordinance 3 GSGV The operator position noise emission value is 70 dB A Power system connection This...

Страница 11: ...ssary to obtain the rated throughput Intel PC or compatible with a Pentium IV 2 GHz processor PCI slot 512 MB RAM Monitor and mouse Supported operating systems Microsoft Windows XP SP3 32 bit Microsof...

Страница 12: ...r cord is disconnected Installing the Kodak Driver software 1 Insert the installation CD in the CD ROM drive The installation program starts automatically 2 Follow the on screen instructions to instal...

Страница 13: ...th document feeding of various sizes thicknesses and textures CAUTION Moving parts avoid contact 3 Elevator tray side guides slide the guides in or out to accommodate the document size you want to sca...

Страница 14: ...etected Illuminates when you need to call Service Refer to Chapter 6 Troubleshooting for complete descriptions of the LED indicators 9 Power switch press the power switch on I or off O as required 10...

Страница 15: ...canner has an upper and lower imaging guide It is important to keep the imaging guides clean to obtain optimum image quality CAUTION Hot surface avoid contact Rollers drive rollers and NFR rollers tra...

Страница 16: ...ed with six power cords Choose the power cord appropriate for your location and connect it accordingly Connect the power cord first to the scanner then to the wall outlet FireWire IEEE 1394 connection...

Страница 17: ...test When completed the top green indicator light will remain on and constant If this does not occur refer to Chapter 6 Indicator lights for more information IMPORTANT Always power up the scanner to...

Страница 18: ...ors its own internal image buffer memory In order to prevent overwriting images before the host computer can retrieve them the scanner will automatically pause the feeder while waiting for the host co...

Страница 19: ...rst while using the gap release lever Ultrasonic multi feed detection is not recommended when using plastic sleeves NOTE When scanning documents in a clear protective sleeve the elevator tray side gui...

Страница 20: ...up to 500 sheets of 75 g m2 20 lb paper Adjusting the side guides and end stop To accommodate multiple applications with variable feeding requirements the side guides can be adjusted for right left or...

Страница 21: ...ve the locking switch into the locked position Adjusting the back of the output tray Different paper types stack differently The output tray can be set in either one of two positions In addition you c...

Страница 22: ...tion and lower the output tray Adjusting the output tray for long documents up to 43 cm 17 in To adjust the output tray to accommodate long documents from 37 cm 14 5 in to 43 cm 17 in 1 Lift the front...

Страница 23: ...e output tray and pull it out of the detent position 2 Place the output tray in the forward detent position 3 Gently push down on the left side of the output tray until in snaps into place 4 Remove th...

Страница 24: ...canners If you have a Kodak i600 Series Scanner the short document tray can be ordered from Parts Services See Chapter 5 Supplies and Consumables for ordering information 1 Remove the end stop on the...

Страница 25: ...canning 1 Align the leading edges of the stacked documents 2 Position the stack of the documents face up in the elevator tray so it covers the paper present sensor NOTE For Kodak i700 Series Scanners...

Страница 26: ...n to allow more documents to be loaded to the bottom of the stack To continuously feed documents follow Steps 1 through 5 above As the documents are being scanned you can continuously add a batch of d...

Страница 27: ...f more than one document is to be scanned feed them one at a time 3 After the document s has been fed release the gap release lever Calibrating the scanner There are two types of calibration that can...

Страница 28: ...e for the TWAIN Datasource The screens displayed on your system may be different 1 Open the pod and clean the imaging guides Refer to the maintenance procedures in Chapter 5 2 If the lamps have not be...

Страница 29: ...A 61500 May 2010 3 13 7 Click the Setup icon to access the main Kodak Scanner window 8 Click Settings The following screen will be displayed 9 Click Device...

Страница 30: ...e following screen will be displayed 10 Click Diagnostics The following screen will be displayed 11 Click Calibrate 12 Select Image Calibration begins A confirmation box is displayed when calibration...

Страница 31: ...e screens shown in this section are for the TWAIN Datasource The screens displayed on your system may be different 1 Center the side guides in the elevator tray and output tray 2 Place the paper in th...

Страница 32: ...me document sequential counter and custom messages The printer is unique in that the document print string can be configured to include both literal static information i e information that stays the s...

Страница 33: ...ased on the complexity of the characters such as half width Katakana Ink cartridge Black HP C6602A Red HP C6602R Green HP C6602G Blue HP C6602B Print side Front pre scan Minimum printing distance from...

Страница 34: ...tions or replacing the ink cartridge carrier you will need to access the Enhanced Printer 1 Remove the output tray 2 Open the printer access cover 3 Do the function you want to perform i e change ink...

Страница 35: ...r from the current print position and place it in the desired position Replacing the ink cartridge Replace the ink cartridge when printed characters appear light or uneven missing characters are evide...

Страница 36: ...rtridge carrier 5 Insert a new ink cartridge into the ink cartridge carrier and close to tab to secure it in place 6 Place the ink cartridge carrier into the desired print position 7 Close the printer...

Страница 37: ...p of ink Replacement blotter strips may be purchased through your supplier 1 Open the pod 2 Locate the two ink blotter strips 3 Carefully pull the blotter strip s off the transport You can replace one...

Страница 38: ...od Replacing the ink cartridge carrier Under normal conditions the ink cartridge carrier should not need to be replaced If you do need to replace the carrier because it is broken or is not getting a g...

Страница 39: ...pull the connector away from the ink cartridge carrier 6 Push the connector firmly into a new ink cartridge carrier 7 Replace the ink cartridge and close the tab to secure it in place 8 Place the ink...

Страница 40: ...cedure as recommended should take approximately 5 to 10 minutes Some document types generate more paper dust and debris and may require more frequent cleaning than recommended NOTES Follow the recomme...

Страница 41: ...utine maintenance on your scanner Use of any other cleaning materials could damage your scanner Kodak Digital Science Transport Cleaning Sheets Kodak Digital Science Roller Cleaning Pads Staticide Wip...

Страница 42: ...34 3680 Kodak Imaging Guide Set for i600 i700 i1800 Series Scanners 197 6703 Kodak Printer Ink Blotters Front Side for i600 i700 i1800 Series Scanners 125 7633 Enhanced Printer Ink Carrier 113 3842 En...

Страница 43: ...e quality Cleaning the output tray and elevator area 1 Power down the scanner and unplug it from the wall receptacle 2 Remove the output tray 3 Thoroughly vacuum the output tray area and the input are...

Страница 44: ...water after performing maintenance procedures 6 Dry the rollers with a lint free cloth Cleaning the separation roller tires 7 Pull the separation pad holder forward and remove the separation roller 8...

Страница 45: ...the printer access cover to release and remove the feed module 13 Manually rotate and wipe the feed module tires with a roller cleaning pad For best results wipe parallel to the ribs in order to remov...

Страница 46: ...ule by aligning the pins fitting it into position and pulling up on the release lever to lock it into place Verify that the feed module is securely in place and moves freely after you install it 16 Cl...

Страница 47: ...ng particular attention to these areas the edges of the transport the reflective tape near the front of the transport the reflective tape near the front of the pod the three paper path sensors at the...

Страница 48: ...s are adhered to 20 Reinstall the upper and lower background strips Cleaning the imaging guides 21 Turn the screw on each end of the upper imaging guide remove it from its position and set it aside IM...

Страница 49: ...h a Staticide wipe IMPORTANT Staticide wipes contain isopropanol which can cause eye irritation and dry skin Wash your hands with soap and water after performing maintenance procedures Refer to the MS...

Страница 50: ...ation Tool dialog box will be displayed 3 Select TWAIN or ISIS for the Driver Types and Kodak Scanner i600 or Kodak Scanner i700 as the Driver and click OK The Scan Validation Tool dialog box will be...

Страница 51: ...ange all the tires on the feed module and separation roller at the same time Feed Module and Separation Roller it is recommended that you install a new feed module and separation roller approximately...

Страница 52: ...le 5 If you are just replacing the feed module Insert the new feed module by aligning the pins fitting it into position and pulling up on the release lever to lock it into place Verify that the feed m...

Страница 53: ...the upper housing up and away from the rollers 7 Remove one core assembly 8 Replace each tire by sliding the tire off the core 9 Install each new tire by gently pulling it over the core IMPORTANT Do n...

Страница 54: ...y snap into place 14 Reinstall the feed module by aligning the pins fitting it into position and pulling up on the release lever to lock it into place Verify that the feed module is securely in place...

Страница 55: ...separation roller Be sure to line up the slots on the separation roller with the holders 4 Push the separation roller holder back in place and close the pod To replace the tires 5 Replace each tire by...

Страница 56: ...Replacing the imaging guides The imaging guides should be replaced when they are heavily scratched and defects show in the image NOTE Handle the imaging guides carefully as to not put fingerprints on...

Страница 57: ...ress the Start Resume button on the scanner or enable scanning from the host or add paper to an empty elevator tray or remove paper from the elevator tray Scanner is powered on and idle Scanner is idl...

Страница 58: ...or details If the condition cannot be cleared call Service Scanner warm up sequence Scanner is enabled Start Resume and Stop Pause buttons are available Scanner is enabled and scanning is allowed Star...

Страница 59: ...ool 1 Select Start Programs Kodak Document Imaging Scan Validation Tool 2 From the Driver Types box select TWAIN 3 Open the Scan Validation Tool 4 Select Kodak Scanner i600 or Kodak Scanner i700 The m...

Страница 60: ...6 4 A 61500 May 2010 6 Click Settings The following screen will be displayed Click Device The following screen will be displayed...

Страница 61: ...creen will be displayed 8 Click the Logs tab 9 From the drop down box select Operator to display the Operator log The most current log entries are displayed at the top of the list See the following Me...

Страница 62: ...re repair Turn the power off to the scanner wait a few seconds and power the scanner back on If the problem persists call Service and provide the ID number of the error Cannot calibrate with white bac...

Страница 63: ...aration roller tires and pre separation pad See Chapter 5 Maintenance for procedures Front calibration failed 110 The front imaging path calibration failed Clean the imaging guides See Chapter 5 Maint...

Страница 64: ...ed at the top of the batch Place the documents in the elevator tray and begin scanning One or more documents that passed through the transport were not scanned Refeed all documents for which images we...

Страница 65: ...e Printer bitmap font in use 281 Informational message An alternate printer font file was found and is being used instead of the default font Rear calibration failed 112 The rear imaging path calibrat...

Страница 66: ...er 3 Calibrating the scanner for procedures UDDS multi feed detected 23 24 334 A multi feed document condition has been detected Check the host monitor to see if there are any overlapped documents tha...

Страница 67: ...t 35 Document too long 36 Document too long 48 Paused waiting for host 63 Scanner paused for rotation or host processing 90 Cannot run with both printers installed 91 Please update firmware before sca...

Страница 68: ...talled 293 Clean upper imaging guide 294 Clean lower imaging guide 297 Input elevator too full feed module missing or broken 319 Cable unplugged 331 Calibration failed 332 UDDS calibration succeeded 3...

Страница 69: ...successfully calibrated Call Service Many ID numbers A condition was detected that may require repair Turn the power off to the scanner wait a few seconds and power the scanner back on If the problem...

Страница 70: ...aration roller tires and pre separation pad See Chapter 5 Maintenance for procedures Front calibration failed 110 The front imaging path calibration failed Clean the imaging guides See Chapter 5 Maint...

Страница 71: ...ned at the top of the batch Place the documents in the elevator tray and begin scanning One or more documents that passed through the transport were not scanned Refeed all documents for which images w...

Страница 72: ...ce Printer bitmap font in use 281 Informational message An alternate printer font file was found and is being used instead of the default font Rear calibration failed 112 The rear imaging path calibra...

Страница 73: ...er 3 Calibrating the scanner for procedures UDDS multi feed detected 23 24 334 A multi feed document condition has been detected Check the host monitor to see if there are any overlapped documents tha...

Страница 74: ...sed 30 Jam in transport 35 Document too long 36 Document too long 48 Paused waiting for host 63 Scanner paused for rotation or host processing 91 Please update firmware before scanning 105 Calibration...

Страница 75: ...talled 293 Clean upper imaging guide 294 Clean lower imaging guide 297 Input elevator too full feed module missing or broken 319 Cable unplugged 331 Calibration failed 332 UDDS calibration succeeded 3...

Страница 76: ...ace these parts if necessary a very dark document on the bottom of a stack or curled document lead edges can sometimes confuse the paper present sensor Place a white sheet of paper at the bottom of th...

Страница 77: ...s desired If you are having problems printing on scanned documents verify that the ink cartridge is not empty make sure that the ink cartridge is properly installed in the Enhanced Printer make sure t...

Страница 78: ...odule and separation roller that are specially designed to feed light weight paper through the scanner transport This accessory includes the following 1 Feed Module 1 Separation Roller 4 Pre separatio...

Страница 79: ...an enhanced printer 130 pages per minute landscape Scanning Output Bi tonal 8 bit grayscale 24 bit color Output Resolution Bi tonal 200 240 300 400 Color 100 150 200 240 300 Grayscale 100 150 200 240...

Страница 80: ...Eastman Kodak Company 343 State Street Rochester NY 14650 U S A Kodak 2010 All rights reserved TM Kodak...

Отзывы: