3. Dryer System Error Messages:
DRYER SENSOR FAULT!
Error activates when
one of the two dryer
sensors is below a
specific value; indicates
an open circuit.
Error activates when
the difference between
the sensors is too great;
the lower sensor value is at fault (the lower sensor value will read below
current room temperature value).
Under Diagnostics Menu > Accessory Menu > Dryer Status, the status of
both sensors is displayed. To determine which sensor has the problem,
disconnect one sensor
connection (J8 or J9 on
dryer board).
The error will be
displayed under ‘Alarms
Menu’ until it is isolated
or fixed. The
‘!’
icon will also be displayed to show the alarm condition is
active.
Error condition will continue to be reported when dryer is switched to ‘Off’ or
‘Fans Only’.
‘Dryer Sensor Fault’ error will not be displayed if both sensors are faulty. If
both sensors are faulty the error ‘
Dryer System Fault - Dryer Off’
will be
displayed (see
DRYER SYSTEM FAULT - DRYER OFF
below).
Action:
Contact technical support.
DRYER SYSTEM FAULT - DRYER OFF
Error condition activates when both dryer sensors are defective or have faulty
connections. Error will still be reported when dryer is switched to ‘Off’ or ‘Fans
Only’. The dryer will then be turned off automatically. Error will repeat (and
sound a beep again) if the user attempts to turn on the dryer.
Error condition occurs when the dryer has no response. This means when the
dryer is turned on (or when changing set points) or if the temperature does