background image

12

13

1. Call household device connected to the common gate camera.
2. Connect call between called household device and common gate camera.
3. I-BUTTON KEY is contacted on I-BUTTON PROBE for 5 seconds.
4. As it is recognized as unregistered I-BUTTON KEY, error sound occurs 5 times consecutively.
5. For 5 seconds, mode entry status is notified in sound.

(Input waiting status notification sound is generated for 10 seconds.)

6. Door opening button is pushed on household device under calling.

(It is registered after recognizing household door opening button.)

7. Buzzer sound advising registration of I-BUTTON KEY after the registration is transmitted.

First registration method of I-BUTTON KEY

1. TACT SWITCH of I-BUTTON PBA is pushed 4 times within 2 seconds.
2. During 2 seconds, total deletion buzzer sound is transmitted and total KEY information is deleted to

be changed as the initial status.

Deletion method 1 of the entire I-BUTTON KEY: Not revealed

1. Two of registered I-BUTTON KEYs are prepared.
2. After calling connected household devices, calls are connected.
3. Under calling status, two KEYs are contacted to I-BUTTON PROBE 4 times in turn during 4 seconds.
4. For 5 seconds, it is entered into mode entry status and buzzer sound is transmitted.
5. For 10 seconds, input waiting status notification buzzer sound is transmitted and within 10 seconds,

door opening button of household device connected to calling is pushed.

6. For 2 seconds, total deletion notification sound is generated and stored KEY information is deleted.

Deletion method 2 of the entire I-BUTTON KEY: Not revealed

1. Under waiting status, TACT SWITCH within I-BUTTON PBA is pushed for 4 seconds.
2. Currently set door opening time buzzer sound is generated for 0.5 seconds.
3. Once internal PCB button is pushed one time, together with buzzer sound, door opening time is

increased per 1 second.

* Do-1 second, Re-2 seconds, Mi-3 seconds, Pa-4 seconds (Basic values), Sol-5 seconds,

La-6 seconds, Si-7 seconds, Do-8 seconds (Maximum)

Set door opening time

1. Registered I-BUTTON KEY is contacted to I-BUTTON PROBE for 5 seconds.
2. After generation of recognition sound of I-BUTTON KEY, common main entrance door is

opened/closed 1 time for the first time.

3. I-BUTTON KEY to register additionally after maintaining contact for 5 seconds is contacted to

I-BUTTON PROBE.

4. When I-BUTTON KEY is registered, registration sound is transmitted.

* In case additionally registering I-BUTTON KEY is contacted to I-BUTTON PROBE within 10 seconds

under the status of registration, it is registered additionally and registration sound is transmitted.
(When10 seconds elapse, completion sound becomes in a status of waiting after transmission.)

Additional registration method of I-BUTTON KEY

I-BUTTON Registration and Deletion

TACT SWITCH Location

Disassemble

back case of

main body

TACT SWICH is necessary to initialize the Common gate camera and to set door opening time.

Only when the power is connected to the Terminal

, TACT SWICH is available.

Operation Explanation

1. When the visitor presses the call button for certain house on the common gate camera,

the certain house monitor gets call signal.

2. In case of hanging up the hand-set or pressing talk button, the conversation is available.
3. When finishing talk, put the hand-set onto the HOOK BAR or press talk button once again.

Communication with house monitor

1. During conversation with household monitor, if the door open button on the monitor is pressed,

the common gate is released, in case the door opener is equiped.

2. Spec of door opener using without power supply : DC 12V / 300mA.
3. In order to connect the door opener to the 2 wire connection (non polarity) on the

common gate camera, you should use KVM-301, KCV-801, KCV-802, KCV-354 monitor only.

Common gate camera from house monitor

1. I-BUTTON KEY registered shall contact on I-BUTTON PROBE.
2. Together with transmission of opening buzzer sound of common main entrance door,

I-BUTTON LED is lit and common main entrance is opened/closed.

Common gate open using I-BUTTON KEY

1

2

TACT SWICH

DC POWER

TERMINAL

I-BUTTON Registration and Deletion

Содержание KVL-C302i

Страница 1: ...down during transport or through careless treatment by consumer b Breakdown cause by unauthorized repair or system modification c Breakdown caused by natural disaster or power disorder 1 Name of the p...

Страница 2: ...of wall mounting type with fixing pegs keep it safely Fixing pegs may cause injury of user Clean the dust inside the product regularly Failure to clean the dust for long time may cause fire For inspec...

Страница 3: ...ving equipment be sure that plug is detached from an outlet and communication cable is disconnected Damage on cables may cause fire Voltage other than prescribed rated voltage is not permitted which c...

Страница 4: ...d sun Beware backlight and darkness of visitor s face which makes identification difficult Avoid installing camera in places such as the following picture 1 Place illuminating sky as background 2 Plac...

Страница 5: ...nal for door opener Power input terminal Power DATA GND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 4 5 6 7 1 9 10 12 14 13 11 3 8 KVL TC308i KVL TC308i I Button Key KVL TC308i KEL T324 Name NO EXTENSION UNIT...

Страница 6: ...OOR RELEASE DC 12V 300mA Door relese Door relese D B C A E Common gate camera to monitor 4pin port wiring upto 50m CAT5 Cable upto 80m TIV 0 6mm 0 3mm Cable upto 100m TIV 0 8mm 0 5mm Cable upto 150m T...

Страница 7: ...conds Si 7 seconds Do 8 seconds Maximum Set door opening time 1 Registered I BUTTON KEY is contacted to I BUTTON PROBE for 5 seconds 2 After generation of recognition sound of I BUTTON KEY common main...

Страница 8: ...wo way Calls images maintains for 30 3 seconds after call Communication with house maintains for 3 minutes 5 seconds This time length depends on each model of house monitor METAL Zn Al SILVER 125 W X...