background image

Video Doorphone Wiring Diagram

Component

Precautions for Operation

Installation Precautions

Monitor and camera must be installed away from direct 

light and counter light.

Camera must be installed at a place free from rain.

Standard height of monitor must be 1,450mm~1,500mm 

from ground, centered around brawn tube.

Camera should be installed on the wall in which cement 
is completely dry.

If installed during winter season at temperature below

-5

, condensation might be generated inside monitor and 

camera due to temperature difference between indoors 
and outdoors. To prevent breakdown due to such 
condensation, connection should be made in 2 hours or 
more after installation.

Do not install monitor and camera in locations subject to 

direct heating as harmful gases may subsequently be 
emitted in significant amounts. 

WARNING

To Reduce the risk of fire orelectric shock Do not expose this appliance to rain ormoisture

CAUTION

To prevent electric shock, match wide blade of plug to wide slot, fullt insert.

Stopping up pipe as above minimizes

temperature  difference  between  indoors
and outdoors, and also eliminates moisture
and condensation on door camera window.

Stop up P.V.C. pipe using

adiabatic substances, to

prevent air circulation

Name of each part

��

Surface-mounting Door Camera Installation 

��

DOOR CAMERA INSTALLATION

After attach the body supporter with 2
screws(4x10mm),
put the Door Camera into the grooves of
body supporter,
and then fix it with a screw(2.6x6mm).

After attach the body supporter with 2
screws(4x10mm), insert the upward
support  into the upward groove of body
supporter, and then fix it with a
screw(2.6x6mm).

Looking “Upward” Installation

Looking 

Downward

Installation 

Straight Ahead Installation

After attach the body supporter with 2
screws(4x10mm), insert the Door Camera
into the downward control groove,  and
then fix it 
with a screw(2.6x6mm).

��

Standard Height of Door Camera

Standard height of the door camera is 1,400mm 

1,450mm from the bottom of one camera to the floor.

In case that the height of Door camera exceeds the 

range of min. 1,250mm

1,550mm, it is 

impossible to control the screen picture with only the 
lens angle, and therefore, be careful of the height of 
camera installation.

Downward control
groove 

Upward control
groove 

Upward control
groove 

(unit:mm)

Door camera Installation

Bottom base of
One hall Box 

Surface mount

Flush mount 

bady support

Upward support

Wall

Screw(4x10mm) 

Screw(2.6x6mm) 

Camera Front

notice

Don’t install the set on a weak or ceiling surface such as plaster or press board, please install the set
on the hard wall or ceiling like firm timber or concrete.

KIV-101 Monitor    

KC-C61 Camera & KC-D30 Metal Pinhole Camera     

C-Mic 

To communicate 
with camera or 
guardroom

Communication  Button 

To communicate with 
camera or guardroom 

Priority 
communication  Button 

To communicate with 
camera first

Camera  Button 

To see the visitor

Guadroom  Button 

To communicate with 
guardroom

Door Release Button

To open the door

Power Lamp 

4 inch screen

To identify

visitor

Brightness Control Knob

To control brightness of

monitor screen

Contrast Control Knob    

To control contrast of 
monitor screen.

Call Signal

Volume Control 

Knob 

To control calling

signal volume.

Speaker Volume

Control Knob 

To control speaker

volume.

AUTO-REC

C-Mic 

To communicate with Monitor 

Power Lamp 

To check power ON/OFF status  

Speaker       

When visitor calls, the voice from monitor 

comes  out of the speaker.

Call Button          

By  pressing  the  button,  the
related house will be called.

Camera Lens        

Clear picture quality realized 
by adopting 1/3" CCD

Option

BENZENE

THINNER

Keep  away  from  humidifier  and
stove.  High  temperature  and
humidity can cause breakdown.

When  cleaning,  never  use  wet
hands,  volatile  benzene  or  paint
thinner.

Keep  picture  clear  by  cleaning
camera  window  frequently  with
soft cloths.

As this device consists of
electronic precision
components, and high voltage is
generated internally, do not
attempt to disassemble. 

Do not drop monitor or door
camera, and avoid strong impact.

Keep away from devices
generating strong magnetic field
(TV, Speaker, etc.)  (Picture can be
disturbed or blurred and breakdown
can result)

KC-C61                                  KC-D30

Power source
Power consumption
Ambient temperature
Braun tube
Communication system
Call signal sound
Output Impedance
Wiring
Max Wiring Distance 

DC12V

±

1V(power from Monitor)

-10

~50

Diagonal 120

Diagonal 90

0.1Lux (LED ON)

F:2.0, f=3.0mm

F:3.5, f=3.8mm

95(W)

×

127(H)

×

34(D)mm

95(W)

×

127(H)

×

33(D)mm

Monitor Accessories

Screws for fixing

(4x25mm)

Wall hanger panel 

Camera Accessories

Monitor & Camera

Main body supporter

Upword adjusting 

Supporter for lens angle

Screw for fixing camera 

to panel (2.6x6mm)

Screw for fixing camera

main body supporter
(4x25mm)

Upward adjusting

supporter for adjusting
lens angle upward

Specifications

MONITOR

(KIV-101)

CAMERA
(KC-C61)

Metal Pinhole

Camera

(KC-D30)

Power source
Ambient temperature
Angle of picture
Min. Illumination
Lens
Dimension

Power Built-in AC 120V 60Hz

Max.15W, Stand by : 1W

0

~+50

4 inch Flat Tube (B/W)

Hands-free system

Camera:Ding-dong, guardroom: Melody

Picture : 75ohm, Voice : 600ohm

4 Wired in polarity /  guardroom Wired in non-polarity

Camera:�

0.65 Single Cable/50m  Guardroom:IV 0.9mm 

��

Wiring Diagram

When system is attached to 1 rectangular switch box

Basic Installation method of Monitor

��

Standard height monitor

Wall hanger panel
for  fixing Monitor 

Wall hanger panel
for  fixing Monitor 

Screw

Wall

1 Rec tangular

switch box

Standard height of monitor is ranged 1,450 ~ 1,500  
from bottom to the center of monitor screen.

For installation, avoid the places where there is any 
excessive humidity,magnetic force, dangerous   
chemicals, direct ray of sun, and any places near a 

heater which can cause break down.

Monitor Installation

(unit:mm)

Screw

Caution for wiring   

Wiring between videophone and camera is 4 wire in polarity and use 

0.65mm or more single cable

Connecting wiring between monitor and door camera should not be installed near other electrical cable,

norbe  horizontal.(In such case, clear picture can not be expected due to interruption by electrical noise)

(Option)

Bottom of
1Rectangular
switch box

Center of monitor

Отзывы: