Call to guardroom - How to communicate

1. When user presses guard/lobby button               , call signal rings and the button's LED is turned on 

to call guardroom phone. 

2. If handset is picked up in guardroom phone, communication begins (for up to 3 minutes). 

3. If hanging up the handset in guardroom or pressing communication            or guard/lobby button              

on videophone, and communication will be automatically ended. 

Call from lobby phone - How to communicate

1. When a call from lobby phone, both communication            and guard/lobby buttons                 flicker 

(tone sound rings for 30 seconds). 

2. Press communication             or guard/lobby buttons               , and communication will be

available (communication lasts for 3 minutes). 

3. Press door open button            on videophone while communicating with lobby phone to operate 

common gate opener.

4. Press either communication            or guard/lobby button              to end communication.

Monitoring of Lobby (Common Gate) Situations

1. If pressing the guard/ lobby button               around 3 sec. on the monitor for about 3sec, the image 

from lobby phone (common gate camera) is displayed on the monitor screen.

But in case the lobby phone (common gate camera) or guardroom phone is busy, the image from

lobby phone (common gate camera) is not displayed.

2. After 8 sec. of lobby (common gate) monitoring, the monitor screen is automatically turned off.

3. In house, the users can see the image and hear the voice from the lobby phone (common gate camera)

for 8 sec.

4. This lobby (common gate) monitoring function is only available with 10 key type of KLP-100,

KLP-P100 & KLP-C100 lobby phone (common gate camera).

Communication is available only when options are installed. If options are not installed, 
only tone sounds rings.  

Call from In-house Line (When options are installed)

1. When internal call signal, in-house line LED at the front side of videophone flickers. 
2. Press either communication           or in-house line button          to start communication 

(LED keeps On-mode). 

3. Communication is available for up to 3 minutes. When 3 minutes pass, communication is automatically     

ended. 

4. Press either communication             or in-house line          to end communication. 

Internal Call using In-house Line (When options are installed)

1. When user presses in-house line button          , the button's LED flicker and a call signal is sent to  

extended unit.

2. Press communication             or in-house line button          on extended unit to begin 

communication (communication maintains for 3 minutes). 

3. Press communication             or in-house line button         to end communication. 

Users can control chime volume by adjusting 3-level volume switch on videophone.

In all functions, call maintenance time is set for 30 seconds. After 30 seconds, call signal and images 
return to stand-by mode. 

All communications maintains for 3 minutes. After 3 minutes, communication automatically 
returns to stand-by mode.

Instructions for Operation 

Model: (KLP-100 / KLP-P100 / KLP-C100), Functional Specifications

Call to house

When a visitor calls to house using lobby phone, press house number. 

> Pressing call button, call sound rings and house is called. 

> If the house responds to the call, communication is available for 3 minutes. 

(Pressing door open button during the communication, opener installed with common gate is opened.) 

> When communication is ended, device returns to standby mode. 

Call from lobby phone to guardroom

Pressing 

0

and call button on the lobby phone, guardroom is called and lobby phone ID is displayed 

in guardroom phone. 

> Communication with guardroom maintains (for 3 minutes). When communication is ended, 

device returns to standby mode. 

Password Change

(Password change function is only available during the call with house.) 

Pressing 

# # 0 0 #

during the call with house, 

- - - -

is displayed. 

Input new password and press 

“#”

button.

e.g) When register passward as ‘1111’. (It should be 4 digits)

Door open using lobby phone with password

Pressing 

house # + pa #

designated by the house, door is automatically opened. 

when the user from house number “0101” opens common gate with passward.     

e.g) Press house number 

0101

, #, passward and # in order.

[Lobby Phone's Direct-Button Call Function]

Model : KLP-104, 108, 112, KLP-P104, P108, P112, KLP-C104, C108, C112

To call to house, press house number using lobby phone's key pad. 

Tone sound rings and call signal is sent to the house. 

Pressing the call button again while calling, calling is cancelled. No separate cancel button is offered. 

If called house is communicating with extended other lobby phones or guardroom phone, 

busy signal sounds and device immediately returns to stand-by mode. 

Operation of Door Opener While Communicating with House

1. Pressing door open button during the communication with house, common gate is opened.

(Door Opener Specification: Within DC 12V 300mA)

Functional specifications may be changed according to the specifications of installed products. 

(Stand-by)                 (House Number)                                    (Call state)          (Communication state)           (Stand-by)

(Stand-by)          (Guard Master Number)                              (Call state)          (Communication state)           (Stand-by)

(Communication state)                    (Password input mode)                                 (Hold)                        (Password)           (# Button)

(Stand-by)                  (House Number)        (# Button)             (Password)             (# Button)   (Releasing common gate)

Содержание KC-C63

Страница 1: ...ity improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control a...

Страница 2: ...e product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or quali...

Страница 3: ...sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can Hig...

Страница 4: ...es should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of...

Страница 5: ...ve minimizes temperature difference between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circul...

Страница 6: ...tion Bottom base of One hall Box Surface mount Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard height monitor Wall hanger panel for fixing Monitor Scr...

Страница 7: ...sed 30m Main Line Communication Line When IV 0 8 is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone...

Страница 8: ...is not available to make conversation with front door camera 4 The DIP switch in sub unit should be set as 0 Cautions Door lock connection Only one door lock should be installed and connected to the m...

Страница 9: ...door open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is dis...

Страница 10: ...line button to end communication Users can control chime volume by adjusting 3 level volume switch on videophone In all functions call maintenance time is set for 30 seconds After 30 seconds call sig...

Страница 11: ...t by DIP switches are summed up e g 1 Above figure turning switch No 1 and No 2 toward On direction value is set at 3 1 2 3 since numbers set by switches are 1 and 2 e g 2 Above figure turning switch...

Страница 12: ...104 KLP 108 KLP 112 KLP C104 KLP C108 KLP C112 KLP P104 KLP P108 KLP P112 house KVM 520 and KIP 603 KIV 102 KIV D102 KIV 202 KIV D202 No setting should be conducted as following instructions A specif...

Отзывы: