Filtration Requirements
ZDM-XX02, -XX04, -XX07:
10
µ
M (1600 mesh)
ZDM-XX08, -XX09:
20
µ
M (750 mesh)
ZDM-XX10, -XX20, -XX40:
50
µ
M (250 mesh)
Maximum Pressure Rating:
Cast Iron: 4500 PSIG
St. Steel: 6500 PSIG
Maximum Temperature Rating
Standard:
-40 to 248°F
Accuracy:
±0.3% of reading with
viscosity >20 cSt.
Repeatability:
±0.05% of reading
Electrical Data
Sensor Type:
Qty. 2 Push-Pull Outputs (Channels A & B)
A & B Signals are 90° out of phase.
Phase difference can be used to determine
flow direction using suitable receiving equipment.
Power Requirements
Voltage (V
cc
):
10-28 VDC
Current:
80 mA max. @ 24 VDC
Power:
1.92 W max. @ 24 VDC
Output Signal
Type:
DC voltage pulse
Form:
Square wave
Amplitude:
Low = GND, High = V
cc
- 1.0 VDC