10. Technical Information 

Installation position: 

vertical 

Accuracy class: 

4 acc. to VDI 

Max. temperature: 

100°C (65°C for PVC) 

Max. pressure: 

01H (L)…37H (L) 16 bar 

 

43H…57H 12 bar 

 

43L…55L 10 bar 

 

63H…65H 8 bar 

 

63L…65L 6 bar 

Calibration conditions:  water: 20°C, air: 20°C,  

air pressure: 1.013 bar abs. 

Ambient temperature: 

-25…+70°C 

Protective category:  

IP 67 

Contact (optional): 

proximity switch: PNP  

open collector, 

n/o contact 

supply voltage: 

10…30 V

DC

  

current consumption:   ≤ 200 mA 
cable: 

2 m, PVC-insulated 

switching state: 

LED, yellow 

 

Material combinations 

Ordering 

code 

Connection 

Float 

Seal 

Ring 

Measuring 

cone 

Housing 

33 

1.4301 

1.4301 

NBR 

PVC 

borosilicate 

glass 

st.st. 1.4301 

55 

1.4404 

1.4404 

FPM 

PTFE 

99** 

1.4301 
1.4404 

 

1.4301 
1.4404 

aluminium 

PTFE 

PVC 

PP 

NBR 

EPDM 

FPM 

PTFE 

PVC 

PTFE 

1.4301 

** Customer specification on request 

 
 
 
 
 
 
 
 
 
 
 

Содержание URM

Страница 1: ...Operating Instructions for Variable area flow meter Model URM...

Страница 2: ...echnical Information 7 11 Order Codes 8 12 Dimensions 9 13 EU Declaration of Conformance 10 14 EU Declaration of Conformance contact 11 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH...

Страница 3: ...fee The devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of a...

Страница 4: ...operating pressures are available Another advantage is offered by the very large sight glass which optically allows direct flow observation 6 Mechanical Connection Before Installation Remove all tran...

Страница 5: ...once in each direction Adjustment of limit values The switch point can be adjusted to the desired levels by using Reference edge approx the middle of the sensor Slide the switch housing up or down unt...

Страница 6: ...the series URM is virtually maintenance free If deposits form on the inner housing or parts periodic cleaning of the unit is recommended Remove the units from the piping with a suitable tool clean the...

Страница 7: ...ent temperature 25 70 C Protective category IP 67 Contact optional proximity switch PNP open collector n o contact supply voltage 10 30 VDC current consumption 200 mA cable 2 m PVC insulated switching...

Страница 8: ...G4 G5 G 3 8 G G 00 none 1A 1x N O PNP 2A 2x N O PNP 24H 10 100 24L 0 32 3 2 24 26H 16 160 26L 0 5 5 0 28 28H 25 250 28L 0 8 8 0 25 360 mm 33H 40 400 33L 1 3 13 36 I4 I5 G G G4 G5 G6 G G G 1 00 none 1...

Страница 9: ...m A mm 3 8 1 1 1 2 2 3 URM xx 0 210 29 5 F M F M URM xx 1 360 F M F M M URM xx 2 40 0 F M F M M URM xx 3 49 5 F M F M M URM xx 4 440 62 0 F M F M F M M URM xx 5 82 0 F M F M F M F M URM xx 6 600 122 0...

Страница 10: ...ch this declaration relates is in conformity with the standards noted below EN IEC 63000 2018 Technical documentation for the assessment of electrical and electronic products with respect to the restr...

Страница 11: ...URM URM K05 0522 page 11 14 EU Declaration of Conformance contact...

Отзывы: