Kobold SZM Скачать руководство пользователя страница 9

 

 

SZM 

SZM K04/0522 

 

page 9 

11. Order Codes 

 

Top and bottom end 

Valves 

Connection 

Scale 

Switches

3)

 

SZM-K = 

1.4301 

 

SZM-S = 

1.4404

 

Top: closed 

0 = Bottom: drain plug 

2 = Bottom: cleaning hole 

4 =  Bottom: drain valve 

 

Top: cleaning hole 

 1 = Bottom: drain plug 

3 = Bottom: cleaning hole 

5 =  Bottom: drain valve 

 

Top: vent valve 

7 = Bottom: drain plug 

8 = Bottom: cleaning hole 

6 =  Bottom: drain valve 

0 = without 
1 = 2 x 

shut-off 
valves 

G4  = union nut G ½ male 

I4  = union nut G ½ female 

N4 = union nut ½" NPT male 

M4 = union nut ½" NPT female 

F4 = loose flange DIN 2526, 

C DN15; PN16 

F5 = loose flange DIN 2526, 

C DN20; PN16 

F6 = loose flange DIN 2526, 

C DN25; PN16 

F7 = loose flange DIN 2526, 

C DN32; PN16 

F8 = loose flange DIN 2526, 

C DN40; PN16 

F9 = loose flange DIN 2526, 

C DN50; PN16 

A4 = loose flange ANSI 

B 16.5 ½"; 150 lbs 

A5 = loose flange ANSI 

B 16.5 ¾"; 150 lbs 

A6 = loose flange ANSI 

B 16.5 1"; 150 lbs 

A7  = loose flange ANSI 

B 16.5 1 ¼"; 150 lbs 

A8  = loose flange ANSI 

B 16.5 1 ½"; 150 lbs 

A9 = loose flange ANSI 

B 16.5 2"; 150 lbs 

B4 = loose flange ANSI 

B 16.5 ½"; 300 lbs 

B5 = loose flange ANSI 

B 16.5 ¾"; 300 lbs 

B6 = loose flange ANSI 

B 16.5 1"; 300 lbs 

B7  = loose flange ANSI 

B 16.5 1 ¼"; 300 lbs 

B8  = loose flange ANSI 

B 16.5 1 ½"; 300 lbs 

B9 = loose flange ANSI 

B 16.5 2"; 300 lbs 

00  = without 

G11) = plastic foil on 

measuring tube 

(2 mm division) 

G21) = engraved 

measuring tube 

(1 cm-division) 

S12)  = sidewise 

Alu-scale (with 

plastic-foil, 

2 mm-division) 

S22)  = sidewise 

engraved 

Alu-scale 

(1 cm-division)

 

 

 

00  = without 

 

1D4) = 1 x N/O, PNP 

2D4) = 2 x N/O, PNP 

nD4) = n x N/O, PNP 

 

1S5)  = 1 x N/O, PNP 

2S5)  = 2 x N/O, PNP 

nS5)  = n x N/O, PNP

 

1) 

scale length = Installation length - 120 mm 

2) 

scale length = Installation length - 100 mm 

3) 

Capacitive sensors 

4) 

Ideal for water, water-based solutions and solvent-based liquids. 

5) 

Ideal for oils, greases, lubricants, inks, acids, sauces, water-based alkalis and cleaning agents. 

Note: Please specify the installation length "L" in clear text, while ordering. 

 
 
 
 
 
 

Содержание SZM

Страница 1: ...Operating Instructions for By pass level indicator Model SZM...

Страница 2: ...echnical Information 8 11 Order Codes 9 12 Dimensions 10 13 EU Declaration of Conformance 13 14 EU Declaration of Conformance contact 14 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH...

Страница 3: ...ces are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents Whe...

Страница 4: ...tallation We recommend that the normaldesign level indicators be fitted on vessels containing pure liquids while the indicators mounted with cleaning stubs a low or low top stub be fitted on container...

Страница 5: ...SZM SZM K04 0522 page 5 7 Electrical Connection 7 1 Capacitive switch option Wiring diagram BN BU pnp BK...

Страница 6: ...If retrofitting of contacts is desired the SZM should be ordered with a remark prepared for retrofitting of limit contact Installing of the capacitive switch Slide the switch housing up until the glas...

Страница 7: ...th cleaning hole Drain the residual medium down from your appliance using the drain valve SZM x5 the cup of cleaning hole SZM x2 SZM x3 or outlet screw SZM x1 If your appliance has shut off valves tur...

Страница 8: ...nection DIN flange DN 15 50 ANSI flange 2 or union nut G NPT Scale resolution engraved 1 cm printed on foil 2 mm Max pressure 10 bar Max temperature 20 C 100 C Density any no float used Max viscosity...

Страница 9: ...150 lbs A7 loose flange ANSI B 16 5 1 150 lbs A8 loose flange ANSI B 16 5 1 150 lbs A9 loose flange ANSI B 16 5 2 150 lbs B4 loose flange ANSI B 16 5 300 lbs B5 loose flange ANSI B 16 5 300 lbs B6 lo...

Страница 10: ...M x x 0 Gx 84 SZM x x 1 Nx SZM x x 0 Nx SZM x x 1 Ix 153 SZM x x 0 Ix 90 SZM x x 1 Mx SZM x x 0 Mx Flange DIN SZM x x 1 Fx 139 SZM x x 0 Fx 76 Flange ANSI 150 SZM x x 1 Ax 141 SZM x x 0 Ax 78 Flange A...

Страница 11: ...Foil on glass tube aluminum scale Limit Contact Mounting Note Customer cannot retrofit the contacts himself If retrofitting of contactsis desired the SZM should be ordered with a remark prepared for r...

Страница 12: ...SZM page 12 SZM K04 0522 Design of the Ends Top Ends Bottom Ends...

Страница 13: ...h this declaration relates is in conformity with the standards noted below EN IEC 63000 2018 Technical documentation for the assessment of electrical and electronic products with respect to the restri...

Страница 14: ...SZM page 14 SZM K04 0522 14 EU Declaration of Conformance contact...

Отзывы: