OPT K02/0410 

8. Technical Information 

Operating temperature: 

-20 to +80 °C 

Operating pressure: 

max. 10 bar 

Protection: IP 

68 

 
Material: 

Housing:  

OPT-_1_ _: Polypropylene 

 

OPT-_2_ _: St. steel (1.4301) 

Sensor: Polysulfone 
Cable: 

Polyurethane 1.5 m, 

 4.5 mm 

O-ring: 

OPT-_2_ _: FPM 

Hexagon nut: 

OPT-_ _10: Polyamide 

Flat gasket: 

OPT-_ _10: FPM 

 
Electrical data

 

Repeatability: ±1 

mm 

Hysteresis: ±1 

mm 

Response time: 

50 µsec (with rising level) 

 

1 sec (with falling level) 

 

depending on viscosity 

 
OPT-0 (OEM-version, without CE-marking) 

Power supply: 

5-12 VDC ± 5 % 

Current input: 

15 mA typ. at V

DC 

(without load) 

Output: 

NPN, open collector, 

 

function N/O contact (WET on) 

Current output: 

10 mA max. at 25 °C 

 

3 mA max. at 80 °C 

OPT-4 

Power supply: 

24 VDC ± 15 % 

Current input: 

17 mA typ. at. 24 V

DC

 (without load) 

Output: 

PNP, Open Collector, 

 

function N/O contact (WET on) 

Current output: 

200 mA, short-circuit-proof 

OPT-5 

Power supply: 

24 VDC ± 15 % 

Current input: 

17 mA typ. at 24 V

DC

 (without load)

 

Output: 

NPN, Open Collector, 

 

function N/C contact (DRY on) 

Current output: 

200 mA, short-circuit-proof 

OPT-6 

Power supply: 

24 VDC ± 15 % 

Current input: 

17 mA typ. at 24 V

DC

 (without load)

 

Output: 

NPN, Open Collector, 

 

function N/O contact (WET on) 

Current output: 

20 mA max., not short-circuit-proof 

 

Содержание OPT Series

Страница 1: ...Operating Instructions for Optical Level Sensor Model OPT...

Страница 2: ...Fax 49 0 6192 23398 E mail info de kobold com Internet www kobold com 2 Note Please read these operating instructions before unpacking and putting the unit into operation Follow the instructions preci...

Страница 3: ...Operating Principle The optical level sensors of model OPT have been developed for monitoring transparent liquids Due to the very small dimensions very slight switching hysteresis and high repeatabil...

Страница 4: ...over In this position drops accumulating on the optical sensor can cause the sensor to report an apparent false simulated level switching point reached Recommended mounting positions On the side wall...

Страница 5: ...l Connection 7 1 General Information Attention Make sure that the voltage values of your system correspond with the voltage values of the measuring unit Make sure that the supply wires are de energise...

Страница 6: ...ng Power supply 5 12 VDC 5 Current input 15 mA typ at VDC without load Output NPN open collector function N O contact WET on Current output 10 mA max at 25 C 3 mA max at 80 C OPT 4 Power supply 24 VDC...

Страница 7: ...sion Housing material Connection female thread OPT 0 5 12 VDC NPN OEM without CE 4 24 VDC 15 PNP 5 24 VDC 15 NPN 6 24 VDC 15 NPN 1 Polypropylene 2 Stainless steel 10 M14 with nut 22 G N4 NPT MSR 010 C...

Страница 8: ...unity a EN 61000 4 4 2002 07 Susceptibility to fast transients IEC 1000 4 BURST b EN 61000 4 2 2001 12 Susceptibility to the discharge of electrostatic electricity EN 61000 6 3 2002 08 Electromagnetic...

Отзывы: