2. Note 

Please read these operating instructions before unpacking and putting the unit 
into operation. Follow the instructions precisely as described herein.  
The devices are only to be used, maintained and serviced by persons familiar 
with these operating instructions and in accordance with local regulations 
applying to Health & Safety and prevention of accidents. 
 
 
 

3. Instrument  Inspection 

These devices are checked before shipping and sent out in perfect condition. 
Should damage to a device be visible, we recommend a thorough inspection of 
the delivery packing. In case of damage, please inform your parcel service/ 
forwarding agent immediately, since they are responsible for damages during 
transit. 

 
Scope of delivery: 

Standard scope of delivery applies:  

  Float switch, model: NSM 

 Operating instruction 

 
 
 

4. Regulation  Use 

These units of type NSM are employed for purposes of monitoring the filling-level 
status of liquids. Only such liquids may be measured which are compatible with 
the materials used in the construction of these units.  
Float switches are usable as switching elements for level control in almost any 
situation, where a two-point control is sufficient to solve the problem under 
consideration. These devices are easy to install and practically maintenance-free. 
Float switches represent an inexpensive solution while offering high reliability at 
the same time. 
 
 
 

Содержание NSM

Страница 1: ...Operating Instruction for Float Switch Model NSM...

Страница 2: ...Mechanical Connection 4 7 Electrical Connection 5 8 Maintenance 5 9 Technical Information 6 10 Order Codes 6 11 Dimensions 7 12 EU Declaration of Conformance 8 Manufactured and Marketed by Kobold Mes...

Страница 3: ...damage please inform your parcel service forwarding agent immediately since they are responsible for damages during transit Scope of delivery Standard scope of delivery applies Float switch model NSM...

Страница 4: ...unting the switching point is determined by means of ballast cable weights 6 Mechanical Connection The float switch cable is fastened centrally between the lower and upper levels The switching angle o...

Страница 5: ...jacketing of the cable and seep along the line into the switch Do not allow the liquid to rise above this end The wiring should be connected either in a dry area or in a junction box satisfying the sa...

Страница 6: ...ene 95 C silicone cable Medium density 0 6 kg l Contact microswitch function changeover contact Switch capacity max 250 VAC max 2 A Class of protection IP 68 Hysteresis min 140 mm max 500 mm 10 Order...

Страница 7: ...NSM NSM K01 1016 Page 7 11 Dimensions 30 100...

Страница 8: ...0730 1 2012 Automatic electrical controls for household and similar use Part 1 General requirements EN 60730 2 15 2011 Automatic electrical controls for household and similar use Part 2 15 Particular...

Отзывы: