11. Technical Data 

Note: 

Kobold Mesura makes every attempt to ensure the accuracy of these 
specifications but reserves the right to change them at any time. 

 
 

  Supply: 24, 110, 230 Vac or 18 to 36 Vdc. 

  Max. Power: 1 VA 

  Process connection: 1G 

  Other connections: Flange DIN, clamp, etc. 

  Power supply and relay status LED. 

  Polycarbonate housing IP.65. 

  Ambient Temperature: -20…+60 ºC. 

  Process Temperature: max. 90ºC (125ºC model H). 

  Cable gland  2 x M20. 

  Relay Output: max. 250 Vca 1 A. 

  Sensitivity adjustment by multi-turn trimmer. 

  Vdc polarity reverse protection. 

  Minimum or maximum security adjustment. 

  Rod version probe covered with PTFE 

 Electromagnetic 

compatibility 

 

   EN 

61010-1:2011 

EN61000-6-2:2006 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание NCW Series

Страница 1: ...Operating instructions for Capacitive Level Monitor NCW...

Страница 2: ...l connection 4 8 Electrical connection 5 9 Adjustment 6 9 1 Module replacement 8 10 Models 9 11 Technical Data 10 12 EU Declaration of conformance 11 13 Notes 12 Manufactured by Kobold Mesura S L U Av...

Страница 3: ...Monitor NCW Cable gland M20 Operating Instructions 4 Description All NCW level switch instruments can be used in any application where one level of liquid in a tank or a silo must be detected 5 Regula...

Страница 4: ...nsure that no such materials remain in the device Make sure that the permitted max operational pressure and temperature limits are not exceeded see Technical Information Protect the measuring sensor f...

Страница 5: ...NCW DT0453 Page 5 8 Electrical connection...

Страница 6: ...supply line Ground terminal is internally tied to the connection thread Be sure that ground line has same potential than ground of thank If you are not sure please do not connect the ground terminal s...

Страница 7: ...avoid a critical adjustment In case of sticky products it is recommended to increase this adjustment The instrument is now adjusted When product will reach the probe relay will be activated and RED L...

Страница 8: ...X and 2 3 and 4 to MIN turn the multiturn potentiomenter totally to clockwise 20 turns RED LED will switch ON 2 In case that RED LED doesn t lights move DIP SWITCH 4 drawing 1 to ON If RED LED still r...

Страница 9: ...NCW DT0453 Page 9 10 Models...

Страница 10: ...n 1G Other connections Flange DIN clamp etc Power supply and relay status LED Polycarbonate housing IP 65 Ambient Temperature 20 60 C Process Temperature max 90 C 125 C model H Cable gland 2 x M20 Rel...

Страница 11: ...Europeas To which this declaration relates is in conformity with the following European Directives Mit folgenden Richtilinien Konform ist auxquels se r f re cette d claration ils sont conformes aux Di...

Страница 12: ...NCW Page 12 DT0453 13 Notes...

Страница 13: ...NCW DT0453 Page 13...

Страница 14: ...NCW Page 14 DT0453...

Страница 15: ...KOBOLD MESURA S L U Avda Conflent N 68 Nave 15 08915 Badalona Tel 34 93 460 38 83 Fax 34 93 460 38 76 E Mail info es kobold com www kobold com Technical data Subject to change without prior notice...