Classification according to Pressure Equipment Directive 2014/68/EU
NBK-03 to NBK-33
Category assignment for not dangerous media (from diagram 2)
Density
[kg/dm³]
PN
[bar]
Kategorie
ML
[mm]
Category
ML
[mm]
Category
ML
[mm]
Category
ML
[mm]
NBK-03
1,0
16
← Cat. I →
4711
← Cat. II →
6000
← Cat. III →
6000
- / -
0,9/0,8/0,7/
0,6/0,54
4600
6000
6000
- / -
NBK-06
1,0
40
1698
6000
6000
- / -
0,9/0,8/0,7
1588
6000
6000
- / -
NBK-07
1,0
63
1060
6000
6000
← Cat. IV →
∞
0,9/0,8/0,7
950
6000
6000
∞
NBK-10
1,0
100
577
4084
6000
∞
0,9/0,8
467
3974
6000
∞
NBK-31
1,0
160
≤2090
5600
- / -
0,9
≤2020
5600
- / -
0,8
≤1900
5400
- / -
NBK-32
1,0
250
≤1180
4410
5600
0,9
≤1110
4340
5600
0,8
≤985
4220
5400
NBK-33
1,0
320
≤1040
4090
5600
0,9
≤970
4010
5500
0,8
≤830
3870
5400
ATTENTION! If the calculated bypass length is exactly within the range limit, then the stricter test method must be used
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition.
Should damage to a device be visible, we recommend a thorough inspection of the
delivery packaging. In case of damage, please inform your parcel service /
forwarding agent immediately, since they are responsible for damages during
transit.
Scope of delivery:
The standard delivery includes:
Bypass Level Indicator
model: NBK-…
4. Regulation Use
Any use of the Bypass level Indicator, model: NBK, which exceeds the
manufacturer’s specification, may invalidate its warranty. Therefore, any resulting
damage is not the responsibility of the manufacturer. The user assumes all risk for
such usage.
The NBK Bypass Level Indicator is used for continuous measurement, indication,
and monitoring of liquids in tanks, vessels, reservoirs, basins etc. The indication
occurs via a magnetically coupled roller indicator.
Содержание NBK-ATEX
Страница 1: ...Operating Instructions for Bypass Level Indicator Model NBK ATEX...
Страница 39: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 39...
Страница 40: ...NBK 03 to 33 ATEX page 40 NBK 03 to 33 ATEX K10 0322 16 Certificates 16 1 NBK EXAM...
Страница 41: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 41...
Страница 42: ...NBK 03 to 33 ATEX page 42 NBK 03 to 33 ATEX K10 0322...
Страница 43: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 43...
Страница 44: ...NBK 03 to 33 ATEX page 44 NBK 03 to 33 ATEX K10 0322...
Страница 45: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 45...
Страница 46: ...NBK 03 to 33 ATEX page 46 NBK 03 to 33 ATEX K10 0322...
Страница 47: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 47...
Страница 48: ...NBK 03 to 33 ATEX page 48 NBK 03 to 33 ATEX K10 0322 16 2 Transmitter LOM...
Страница 49: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 49...
Страница 50: ...NBK 03 to 33 ATEX page 50 NBK 03 to 33 ATEX K10 0322...
Страница 51: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 51...
Страница 52: ...NBK 03 to 33 ATEX page 52 NBK 03 to 33 ATEX K10 0322...
Страница 53: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 53 16 3 Limit contact RA excerpt...
Страница 54: ...NBK 03 to 33 ATEX page 54 NBK 03 to 33 ATEX K10 0322...
Страница 55: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 55...
Страница 56: ...NBK 03 to 33 ATEX page 56 NBK 03 to 33 ATEX K10 0322...
Страница 57: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 57...