4. Regulation Use 

Any  use  of  the  Bypass-Level  Indicator,  model:  NBK-19,  which  exceeds  the 
manufacturer’s  specifications,  may  invalidate  its  warranty.  Therefore,  any 
resulting damage is not the responsibility of the manufacturer. The user assumes 
all risk for such usage.  
 
 
 

5. Operating Principle 

The Kobold bypass level indicator type NBK-19 is based on the simple principle 
of cable and deflection pulley. The tank float, made of PPH or stainless steel, is 
moved  upwards  and  downwards  by  the  medium  according  to  the  liquid  level  in 
the  tank.  The  tank  float  has  a  counter  float  (counterweight)  which  moves  in  a 
transparent PVC tube depending on the liquid level. The two floats are connected 
to each other through a cable and 2 deflection pulleys. The magnetic counter float 
has a ring marker for reading of the scale on the bypass PVC tube. 
 
The following options are available: 
 

 

Magnet roller indicator 

When the counter float travels past the red/white rollers, they rotate through 
180°. The rollers change from white to red when the liquid level rises and from 
red to white when the level falls. The liquid level is continuously indicated as a 
red column, even in the event of a power outage. 
 

 

Measurement transducer: 

For remote transmission of the liquid level, a measurement transducer with 
reed chain or a magnetostrictive sensor can be mounted on the outside of the 
bypass tube. Using a built in transducer, a continuous standard signal of 4 to 
20 mA is transmitted. This standard signal can be displayed using an 
analogue or digital indicator device. 
 

 

Universal indicator device:

 

An  ADI  series  universal  indicator  device  can  be  connected  to  indicate  and 
evaluate  the  standard  signal  (4  to  20  mA)  produced  by  the  measurement 
transducer. For reasons of stability, this device is not mounted on the bypass 
tube, but is supplied with wall mountings. 
 

 

Limit contacts:  

One or more reed contacts can be attached to the bypass tube to monitor the 
limit values or to control the liquid level. 

 
 
 
 

Содержание NBK-19

Страница 1: ...Operating Instruction for Bypass Level Indicator Cable version Model NBK 19...

Страница 2: ...7 4 Measurement transducer Magnetostrictive sensor with 4 wire transmitter option T 8 8 Operation 9 8 1 Operation of the level indicator 9 8 2 Operation of the electrical limit contact 9 9 Fault diagn...

Страница 3: ...tions can also be sent to you by post in paper form against an applicable postage fee The devices are only to be used maintained and serviced by persons familiar with these operating instructions and...

Страница 4: ...Magnet roller indicator When the counter float travels past the red white rollers they rotate through 180 The rollers change from white to red when the liquid level rises and from red to white when t...

Страница 5: ...e tank or in an appropriate manner Remove the packaging from the bypass float pull the float a little upwards in the tube and fix in place Snap the bypass tube into the pipe clamps adjust and place th...

Страница 6: ...al power supply is deenergised To avoid disturbances from electric fields of other electrical circuits the cable should not be laid together with other high voltage cables Remove the cover and run the...

Страница 7: ...rical power supply is deenergised To avoid disturbances from electric fields of other electrical circuits the cable should not be laid together with other high voltage cables Remove the cover and run...

Страница 8: ...deenergised To avoid disturbances from electric fields of other electrical circuits the cable should not be laid together with other high voltage cables Remove the cover and run the power supply cable...

Страница 9: ...lack wire represents the common terminal for both switches N C and N O So that the switch function corresponds to the wiring diagram the table below the float must pass the contact once in both direct...

Страница 10: ...cable is loose when the tank is full The bypass float is resting on the base of the tube The cable is too long The bypass float knocks against the head of the tube The tank float is partly or complete...

Страница 11: ...transparent glued to the tube Roller indicator Red white PP tmax 60 C pmax Unpressurised Viscosity 1 200 mm s Limit contact type NBK R Contact function bi stable SPDT contact Switching hysteresis abo...

Страница 12: ...vironmental temperature max 60 C Protection index IP 65 Resolution 10 mm ML 2000 mm 20 mm ML 2000 mm Measurement transducer type T Magnetostrictive sensor with 4 wire transmitter Output 4 20 mA Workin...

Страница 13: ...r indicator 0 without T Magnetostrictive sensor W reed contact chain M Reed contact chain with transmitter W PPH Z 1 4301 0 without M Polyester scale NBK R Standard limit contact NBK 19BF Fastening cl...

Страница 14: ...NBK 19 Seite 14 NBK 19 K03 0322 12 Dimensions NBK 19 with Option W PPH float...

Страница 15: ...NBK 19 NBK 19 K03 0322 Seite 15 NBK 19 mit Option Z stainless steel float 200 100 ML 50 50 L 0 10 60 cm 8 5 25 50 20 63x3 89 51 5 ca 36...

Страница 16: ...8 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances The bypass level indicators with measurement transducer Type...

Страница 17: ...following EEC guidelines have been fulfilled 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive 2011 65 EU RoHS category 9 2015 863 EU Delegated Directive RoHS III Hofheim 29 July 2021 H Volz M...

Страница 18: ...2018 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances The bypass level indicators with measurement transducer Ty...

Страница 19: ...ctrical Equipment Safety Regulations 2016 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 S I 2012 3032 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electr...

Отзывы: