11.  Order Codes 

Order Details

 (Example: 

DPL-1P05 G4 0000

 

 

Meas. 
range 

L/min

 

water 

 

approx. 

frequency 

Hz

 at 

max. value 

 

approx. 

pressure 

loss 

bar

 at 

max. value

 

Gasket model 

 

Connection 

 

Electronic analyser 

NBR 

FPM 

EPDM 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

G4..

G 1/2 male 

 

S4..

Hose connector 
 
for inner 
diameter of 
Hose 
12 mm + 14 mm 

Frequency output 

 

..0000

 = Frequency output, NPN, without cable (OEM), no CE 

 

..F300

 = Frequency output, plug connector M12x1, PNP 

 

..F320

 = Frequency divider 1:2, plug connector M12x1, PNP 

 

..F340

 = Frequency divider 1:4, plug connector M12x1, PNP 

 

..F390

 = divider 1...

1

/128, plug connector M12x1, PNP 

 

..F500

 = Frequency output, PNP, 2 m PVC cable 

 

..F520

 = Frequency divider, 1:2, 2 m PVC cable, PNP 

 

..F540

 = Frequency divider, 1:4, 2 m PVC cable, PNP 

 

..F590

 = divider 1...

1

/128, 2 m PVC cable, PNP 

 

Analogue output 

 

..L303

 = 0 - 20 mA output, M12x1 plug connector 

 

..L343

 = 4 - 20 mA output, M12x1 plug connector 

 

..L403

 = 0 - 20 mA output, plug connector DIN 43 650 

 

..L443

 = 4 - 20 mA output, plug connector DIN 43 650 

 
 

Compact electronics* 

 

C30R

 = LED display, 2x open collector, PNP, plug connector 

M12x1 

 

C30M

 = LED display, 2x open collector, NPN, plug connector 

M12x1 

 

C34P

 = LED display, 4 - 20 mA, 1x open coll., PNP, plug con. 

M12x1 

 

C34N

 = LED display, 4 - 20 mA, 1x open coll., NPN, plug con. 

M12x1 

 

0.025 - 

0.5 

272 

0.77 

DPL-1P05  DPL-1V05

DPL-1E05

0.05 - 1.8 

471 

0.77 

DPL-1P10  DPL-1V10

DPL-1E10

0.2 - 6 

505 

0.70 

DPL-1P15  DPL-1V15

DPL-1E15

0.4 - 12 

265 

1.0 

DPL-1P20  DPL-1V20

DPL-1E20

1 - 25 

399 

1.3 

DPL-1P25  DPL-1V25

DPL-1E25

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

 

*please specify flow direction in writing 

 

 

Plug-on display 

for model DPL...L443 (with 4 – 20 mA output and plug connector DIN 43650) 

 

Description 

Order number 

3-digit LED, plug connector DIN 43 650, 

3-wire, power supply through analogue output 

AUF-3000 

Содержание DPL-1E Series

Страница 1: ...Operating Instructions for Low Volume Rotating Vane Flow Meter Model DPL 1P DPL 1V DPL 1E...

Страница 2: ...able outlet with M12x1 angle plug electronic options F3x and L3x 7 7 6 Compact electronics C30R C30M C34P C34N 7 8 Commissioning Evaluating Electronic 8 8 1 Frequency output 8 8 2 Analogue output 8 8...

Страница 3: ...with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents When used in machines the measuring unit should be used only when the...

Страница 4: ...rical output is available as an option The frequency is proportional to the flow velocity The vane has a sapphire bearing and ensures a high degree of linearity and long service life 6 Mechanical Conn...

Страница 5: ...the unit s electronics 7 2 DPL 0000 frequency output OEM without cable Feed voltage receiver 4 5 16 VDC Feed current receiver typ 7 mA Signal amplitude High approx operating voltage Signal amplitude L...

Страница 6: ...ectronic Frequency output Plug connection M12x1 F3 Cable connection F5 7 4 Evaluating electronic Analogue output L 3 wire connector M12x1 3 wire DIN plug 43650 DPL L303 L343 DPL L403 L443 1 2 3 4 Vs S...

Страница 7: ...L3x When using a pre assembled M12x1 connection cable with angled plug the cable outlet is always aligned opposite to the flow direction 7 6 Compact electronics C30R C30M C34P C34N See Operating Instr...

Страница 8: ...ion ready for operation 8 2 Analogue output The measuring instruments are preset and after connection ready for operation 8 3 Compact electronics The measuring instruments are preset and after connect...

Страница 9: ...tic filter model MFR If cleaning of the sensor is necessary the sensor can be opened so that the inner parts are accessible Take care that the sensor and especially the vane are not damaged make sure...

Страница 10: ...er supply 4 5 12 VDC Supply current approx 7 mA Signal amplitude high approx power supply Signal amplitude low 0 2 V Transmitter cut off voltage 3 V max Transmitter supply current 15 mA 25 mA Output l...

Страница 11: ...43 650 Option plug on display with plug connector DIN 43 650 and output 4 20mA Compact electronics Display 3 digit LED Analogue output 0 4 20 mA adjustable max 500 Switching outputs 1 2 semiconductor...

Страница 12: ...m PVC cable PNP Analogue output L303 0 20 mA output M12x1 plug connector L343 4 20 mA output M12x1 plug connector L403 0 20 mA output plug connector DIN 43 650 L443 4 20 mA output plug connector DIN...

Страница 13: ...DPL DPL K07 0322 page 13 12 Dimensions DPL 0000 DPL F3 DPL L3 DPL C3 with compact electronic DPL L4 with analogue output and plug on display...

Страница 14: ...ility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61010 1 2011 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General require...

Страница 15: ...ents BS EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use General requirements BS EN 60529 1992 A2 2013 Degrees of protection provided by enclosur...

Отзывы: