9.1  Disassembly of DON with Pulse meter  

Concerning options Hx, Dx, Gx, Bx, Kx and Rx 

9.1.1 

Pulse output board

 

removal (refer exploded view diagram) 

To remove the pulse output board, remove the 4 electronic cover screws (10), 
and remove the electronic cover (9). The pulse output board (6) can now be 
accessed and removed via the removal of the electronic board screws (7). 

9.1.2 

Oval gear removal for DON-x05…DON-x15 (refer exploded view 

diagram) 

For access to the oval wheel, remove the 4 lower meter body screws (5). With 
care, remove the upper meter body assembly (4) being careful not to damage or 
misplace the O-ring (3) or changing the positioning of the oval wheels (2) and/or 
damaging them. 
For DON models DON-x05 to DON-x10, when disassembling, please notice the 
notches located on the meter bodies (1 & 4) face just outside the o-ring groove. 
These markings must be matched during assembly. Only one oval wheel is 
equipped with a magnet in these small flow meters. It must be mounted on the 
bearing shaft opposite to the notch. For these oval wheels, the sides without 
boring hole for the magnet must face upwards, see detail A. For all other devices 
(DON-x15 and larger) both gears are equipped with magnets and can be 
mounted in any position. 

Содержание DON-130GA8

Страница 1: ...Operating Instructions for Oval Gear Flow Meter Model DON Lx Hx Rx Dx Gx Kx Bx Zx M4...

Страница 2: ...ssembly of DON with Pulse meter 23 9 2 Demounting of the electronics mounted on a DON with Zx and Ex options 30 9 3 Spare Parts 30 9 4 Inspection refer Exploded View 30 9 5 Re assembly of DON 30 10 Te...

Страница 3: ...odel DON DN Pmax bar diagram 8 group 1 dangerous liquids diagram 9 group 2 no dangerous liquids DON 105 64 art 4 par 3 art 4 par 3 DON 110 64 DON 115 64 DON 120 64 DON 125 25 64 DON 130 40 40 DON 135...

Страница 4: ...category II DON 45 3 16 category II DON 50 3 16 category II DON 55 4 16 category II DON 60 4 16 category II DON 2 8 Stainless steel with mechanical totalizer Option M4 Model DON 2 8 DN Pmax bar diagra...

Страница 5: ...are suitable for fuels fuel oils lubricating liquids It is important to ensure that the medium to be measured is compatible with the materials used in the instrument See section 10 Technical Data It...

Страница 6: ...via a remote display controller or PLC or via a variety of output display options available as accessories attached to the flowmeters The positive displacement flow technology allows for precise flow...

Страница 7: ...t the operational pressure and temperature limits are within capability of the fully specified meter Verify that the operational flow rates are within the specified flow range Viscous liquids may limi...

Страница 8: ...it the installation The DON flowmeter accommodates both horizontal and vertical flows It is recommended that for vertical flow installations that the liquid flow up through the meter i e bottom to top...

Страница 9: ...from the system and serviced as needed System purging is also possible with a by pass arrangement Accommodate all meter ratings and locate the meter on the discharge side of the process pump For outd...

Страница 10: ...Reed contact R0 option and without ATEX labelling For this purpose intrinsically safe cabling must be laid between the instrument the hazardous area and an approved isolation switching unit outside t...

Страница 11: ...electronics options combine a hall effect sensor with an active push pull output stage The B0 BE options involve combining bipolar Hall sensors with alternating polarised magnets This option is partic...

Страница 12: ...ons If the intention is to operate the dry reed contact impulse output in ATEX areas as simple apparatus only the R0 option may be used Note when using the reed switch output the liquid temperature mu...

Страница 13: ...fe or even destroy the contact For capacitive and inductive loads e g via long lines we recommend the following protective circuits Lamp load with series or parallel Protection with a RC suppressor re...

Страница 14: ...is best suited for verified use with a redundant signal or for counting bidirectional currents detecting the current direction Max output current per channel power source or sink 100 mA short circuit...

Страница 15: ...ptions Ex Zx The Ex Zx electronic options are pre configured ex works in connection with the sensor boards Reconfiguration is available on request 7 4 1 For Z1 Z3 electronic options reed switch and Ha...

Страница 16: ...sensor recommended in connection with external supply 7 4 2 For Z6 Z7 electronics options bipolar Hall sensor The circuitry corresponds to 7 4 1 b 7 4 3 For E1 E5 electronics options Refer operating i...

Страница 17: ...DON DON 01 1019 page 17 7 4 4 For Z2 Z8 Z9 electronics options 2 Hall sensors for direction detection...

Страница 18: ...y is correct All DON devices with L0 LE options are factory calibrated to the respective measurement range end value This setting should only be modified by the manufacturer 7 4 6 Calibration Factor s...

Страница 19: ...DON DON 01 1019 page 19 7 5 External wiring with electronic unit ZOK Zx 7 5 1 Wiring with ZOK ZxK a Circuit with Hall sensor not for battery operation b Circuit with Reed switch...

Страница 20: ...DON page 20 DON 01 1019 7 5 2 Wiring with ZOK ZxP a Circuit with Hall sensor b Circuit with Reed switch...

Страница 21: ...purged of air During long periods of inactivity or after a flushing air may be in the piping Elimination of the air may be achieved by operating the meter at a low flow rate until all the air is elim...

Страница 22: ...de energized or removed from the circuit Oval gear positive displacement flowmeters are mechanical by nature A periodic maintenance inspection schedule is suggested for an extended service life Follow...

Страница 23: ...s 5 With care remove the upper meter body assembly 4 being careful not to damage or misplace the O ring 3 or changing the positioning of the oval wheels 2 and or damaging them For DON models DON x05 t...

Страница 24: ...s for DON x20 refer exploded view For access to the oval gears remove the 6 upper meter body screws 5 With care remove the upper meter body assembly 4 being careful not to damage or misplace the O rin...

Страница 25: ...0 refer exploded view For access to the oval gears remove the 8 upper meter body screws 5 With care remove the upper meter body assembly 4 being careful not to damage or misplace the O ring 3 You can...

Страница 26: ...ars for DON x45 DON x60 refer exploded view For access to the oval gears remove the 8 upper body screws 5 With care remove the upper body assembly 4 being careful not to damage or misplace the O ring...

Страница 27: ...ove lower housing section 5 Remove seal 4 washer 3 and seal 2 When assembling it is important to ensure the oval gear of 3 is correctly positioned relative to the counting mechanism 8 When mounting th...

Страница 28: ...DON page 28 DON 01 1019 DON x25 to x40 DON x45 to x60...

Страница 29: ...hanical counter display comprises a 4 digit mechanical totalizer 1 and an 8 digit sum display 2 Depending on the order option the display is calibrated in either litres or gallons The totalizer displa...

Страница 30: ...e oval gearbox housing should be loosened 9 3 Spare Parts Please consult your closest KOBOLD Office Internet www kobold com or www koboldusa com 9 4 Inspection refer Exploded View Inspection points wi...

Страница 31: ...rrect seating wear of bearing shafts and bearings by slowly turning the gears by hand Then insert the O ring 3 into the groove of the measuring housing 1 and assemble both parts 1 and 4 For the smalle...

Страница 32: ...l not completely rotate freely unless installed precisely 90 from each other Proper placement of the O ring within the groove is necessary for leak free operation After placement items 1 4 will then r...

Страница 33: ...e tightening torque Model Housing screws Connections and axes Thread Torque Nm Thread Torque Nm x05 x15 M5 6 x20 x25 M6 10 M8 16 x20 x25 M6 20 M8 16 x30 x40 M10 32 M10 32 x45 x60 M10 32 M12 56 Steel s...

Страница 34: ...es stainless steel 1 4404 O Rings medium temperature FKM 20 120 C NBR 20 100 C FEP O seal FKM 15 130 C Cover for cable connection polyamide PA6 GF35 UL94 HB VO DON 1 stainless steel 1 4404 DON 2 und D...

Страница 35: ...load pulse output Hall pulse output active push pull max 100 mA short circuit proof HIGH level Min Vs 1 3 V LOW level max 1 3 V Reed pulse output as for R0 RE HU electronics option Supply voltage 5 t...

Страница 36: ...nnection plug in terminals Z1 electronics option Signal inputs 2x configurable Dual counter Daily overall counter 1x per input Signal outputs none Z2 electronics option Signal inputs 1x configurable B...

Страница 37: ...ier for higher viscosities Viscosities cP Standard rotor Special cut rotor 1000 1 1 2000 0 5 1 4000 0 42 0 84 6000 0 33 0 66 8000 0 25 0 5 30000 0 15 0 3 60000 0 12 0 25 150000 0 1 0 2 250000 0 05 0 1...

Страница 38: ...l sensor Bx Quadr hall sensor Dx Hall sensor high resolution Gx Hall sensor high resolution Kx DON X05 0 5 36 L h 2670 2670 2670 11320 5340 DON X06 2 36 L h 2670 2670 DON X10 2 100 L h 1062 1062 1062...

Страница 39: ...DON DON 01 1019 page 39 11 Pressure drop curves...

Страница 40: ...DON page 40 DON 01 1019...

Страница 41: ...N 810H R2 G N2 NPT 15 550 l h DON 115H DON 215H DON 815H R3 G N3 NPT 1 40 DON 120H DON 220H DON 820H R4 G N4 NPT H45 G 100 bar P45 NPT 100 bar 10 150 DON 125H DON 225H DON 825H R6 G 1 N6 1 NPT F6 DIN...

Страница 42: ...DON page 42 DON 01 1019 13 Dimensions Electronic Options Ex Zx Option M N standard Option S T with cooling fin...

Страница 43: ...etc Step 3 Guarantee flow rate Flow stopping or a flow rate declining below the usual limit may be attributable to a blocked screen flowmeter rotors which are stuck or damaged a defective pump closed...

Страница 44: ...amber 3 Disruption of the output signal 1 Ground shielding of the signal cable 2 Re lay the cable away from sources of high current 3 Check all electrical connections and wires for the presence of cur...

Страница 45: ...the label for group I the surface temperature of the process fluid must not exceed 150 C Ex IIC T4 T6 Devices for use in areas with potentially explosive atmospheres outside the mining field but with...

Страница 46: ...unter has been calibrated to function with mineral oil which means the remainder of the calibration oil still remains in the device The oil used for measurement ranges X05 to X20 SHELL Morlina 10 for...

Страница 47: ...ronic are in conformance with 2012 19 EU WEEE Waste Electrical Electronic Equipment 2014 30 EU EMC Directive EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC require...

Страница 48: ...ing a surface area between 20 mm and 100 mm will be classified T4 when the matched output power of the interface device does not exceed 1 3W into 40 C ambient 1 2W into 60 C ambient 1 0W into 80 C amb...

Страница 49: ...DON DON 01 1019 page 49 18 Exd Certificate...

Страница 50: ...DON page 50 DON 01 1019...

Страница 51: ...DON DON 01 1019 page 51...

Страница 52: ...DON page 52 DON 01 1019 19 IECEx Certificate...

Страница 53: ...DON DON 01 1019 page 53...

Страница 54: ...DON page 54 DON 01 1019...

Страница 55: ...DON DON 01 1019 page 55...

Страница 56: ...DON page 56 DON 01 1019 20 State of safeness...

Отзывы: