DON
page 44
DON K18/0418
Klemmenab-
deckungsschraube
Klemmen-
abdeckung
Ausgangs-
platine
Exd
Kennzeichnung
Nieten
Typenschild
Gerätekopf
15. ATEX Exd version
Concerning electronic options RE / BE / HE / DE / GE / KE / LE)
Products which were ordered with the optional encapsulated pressure-proof
connector housing (Exd) are marked with an ATEX label (see figure). The label
includes details relating to explosion group and temperature class. Before
installing and operating the device, the label should be checked to ensure it
contains all the required details.
The relevant explosion groups and temperature classes are as follows:
Ex I
: Devices for use in mining with mine gas accumulation. Mine gas refers to
the methane gas naturally generated from coal and coal seams in the coal mining
industry.
Only stainless steel devices
are suitable for use in explosion group I
(in accordance with IEC 60079-0, section 8.1.1). Aluminium devices are not
permitted for explosion group I. If the flowmeter includes the label for group I, the
surface temperature of the process fluid must not exceed 150 °C.
Ex IIC T4/T6:
Devices for use in areas with potentially explosive atmospheres
outside the mining field, but with mine gas accumulation. Either aluminium or
stainless steel devices may be used in explosion group II. For T4 temperature
class applications, the surface temperature of the process fluid must not exceed
120 °C, and for T6 temperature class applications, the surface temperature of the
process fluid must not exceed 70 °C.
Operating instructions
:
The Exd device must be removed from
the explosive zone before the terminal
cover can be opened.
The maximum permissible annular gap
between the terminal cover and the
measuring device must not exceed 0.15 mm.
If the annular gap exceeds 0.15 mm due to
corrosion or wear and tear, the worn out
parts must be replaced.
The product does not meet the requirements
of the Exd protection class unless the
terminal cover is completely snapped into
place and screwed down. No other screw
sizes or lengths may be used than the ones
of the original screws.
Terminal cover
screws
Rivets
Type plate
Device head
Terminal cover
Output board
Exd label
Содержание DON-05Bx
Страница 1: ...Operating Instructions for Oval Gear Flow Meter Model DON Lx Hx Rx Dx Gx Kx Bx Zx M4 ...
Страница 17: ...DON DON K18 0418 page 17 7 4 4 For Z2 Z8 Z9 electronics options 2 Hall sensors for direction detection ...
Страница 20: ...DON page 20 DON K18 0418 7 5 2 Wiring with ZOK ZxP a Circuit with Hall sensor b Circuit with Reed switch ...
Страница 28: ...DON page 28 DON K18 0418 DON x25 to x40 DON x45 to x60 ...
Страница 38: ...DON page 38 DON K18 0418 11 Pressure drop curves ...
Страница 39: ...DON DON K18 0418 page 39 ...
Страница 40: ...DON page 40 DON K18 0418 12 Order codes Please refer to separate datasheet ...
Страница 48: ...DON page 48 DON K18 0418 18 Exd Certificate ...
Страница 49: ...DON DON K18 0418 page 49 ...
Страница 50: ...DON page 50 DON K18 0418 ...
Страница 51: ...DON DON K18 0418 page 51 19 IECEx Certificate ...
Страница 52: ...DON page 52 DON K18 0418 ...
Страница 53: ...DON DON K18 0418 page 53 ...
Страница 54: ...DON page 54 DON K18 0418 ...
Страница 55: ...DON DON K18 0418 page 55 20 State of safeness ...