Kobold DAG-A14 Скачать руководство пользователя страница 16

DAG-A14 

page 16 

 

DAG-A14 K05/0622 

14. Safety advice 

Please  read  the  following  safety  advice  and  the  assembly 

chapter 6 

before 

installation and keep it  for future reference. 

 

Proper use

 

 

The 

DAG-device 

is designed for the evaluation and display of Pt100 signals. 

 

Danger!  Careless  use  or  improper  operation  can  result  in 

personal injury and/or damage to the equipment.

 

 
 

Control of the device

 

The panel meters are checked before dispatch and sent out in perfect condition. 
Should  there be  any  visible  damage, we  recommend close  examination  of  the 
packaging. Please inform the  supplier immediately of any damage. 

 

Installation

 

The 

DAG-device 

must be installed by a suitably 

qualified specialist 

(e.g. with a 

qualification in  industrial electronics). 

 

Notes on installation

 

• 

There must be no magnetic or electric fields in the vicinity of the device, 
e.g. due to  transformers, mobile phones or electrostatic discharge. 

• 

The 

fuse rating 

of the supply voltage should not exceed a value of 

0.5 A N.B. 

fuse

• 

Do not install inductive consumers (relays, solenoid valves etc.) near the 
device  and  suppress  any  interference  with  the  aid  of  RC  spark 
extinguishing combinations or free-  wheeling diodes. 

• 

Keep input, output and supply lines separate from each other and do not lay 
them  parallel  with  each  other.  Position  “go”  and  “return  lines”  next  to  one 
another. Where possible  use  twisted  pair. So, the best measuring results can 
be received. 

• 

Screen  off  and  twist  sensor  lines.  Do  not  lay  current-carrying  lines  in  the 
vicinity. Connect the 

  screening  on  one  side 

on  a  suitable  potential  equaliser  (normally  signal 

ground). 

• 

The device is not suitable for installation in areas where there is a risk of 
explosion. 

• 

Any  electrical  connection  deviating  from  the  connection  diagram  can 
endanger  human  life 

• 

and/or can destroy the equipment. 

 

Содержание DAG-A14

Страница 1: ...Operating Instructions for Digital Indicating Unit for Panel Mounting Model DAG A14 Pt100 2 3 wire 200 850 C 328 1562 F...

Страница 2: ...ontents 2 2 Note 3 3 Instrument Inspection 3 4 Regulation Use 3 5 Brief description 4 6 Assembly 4 7 Electrical Connection 5 8 Function description and operation 6 9 Setting up the device 7 9 1 Switch...

Страница 3: ...devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accident...

Страница 4: ...in terminals Selectable functions like e g the recall of the min max value an impedance matching up to 20 C and a direct change of the limit value in operating mode complete the modern device concept...

Страница 5: ...A143000R supply of 24 VDC Advice The galvanic isolation in devices with temperature sensors that do not have a galvanic connection to an extrinsic potential can be cancelled by a bridge from terminal...

Страница 6: ...always indicated with a flashing of the display Adjustments made at the parameterization level should be always confirmed by pressing the P key to save them However the display automatically saves all...

Страница 7: ...ce For 1 second during the switching on process the segment test 8 8 8 8 8 is displayed followed by an indication of the software type and after that also for 1 second the software version After the s...

Страница 8: ...ogramming Interlock RUN 9 4 Extended parameterization By pressing the buttons during standard parameterization for one second the display switches to the extended parameterization mode Operation is th...

Страница 9: ...DAG A14 DAG A14 K05 0622 page 9...

Страница 10: ...DAG A14 page 10 DAG A14 K05 0622...

Страница 11: ...following procedure should be used Switch off the power supply Press button P Switch on voltage supply and press P button until is shown in the display With reset the default values of the program ta...

Страница 12: ...An activated set point can be optically indicated by flashing of the 7 segment display Functional principle of the alarms Alarm Deactivated display value Threshold Threshold limit value for switch ove...

Страница 13: ...s section up to 2 5 mm2 Display Digit height 10 mm Segment colour red optional green orange or blue Display range 1999 to 9999 Setpoints optical display flashing Overflow horizontal bars at the top Un...

Страница 14: ...emperature 0 C 60 C Storing temperature 20 C 80 C Weatheringresistance relative humidity 0 80 on years average without dew EMV EN 61326 CE sign Conformity to directive 2014 30 EU Safety standard Accor...

Страница 15: ...DARD TYPES ORDER NUMBER Pt100 2 3 wire Housing size 48x24 mm DAG A143000R DAG A14 3 0 0 0 R Supply 3 24 VDC galvan isolated Output 0 without Sensorsupply 0 without Contact 0 without Display R red B bl...

Страница 16: ...c fields in the vicinity of the device e g due to transformers mobile phones or electrostatic discharge The fuse rating of the supply voltage should not exceed a value of 0 5 A N B fuse Do not install...

Страница 17: ...tion High voltages can cause dangerous body currents Galvanic isolated potentials within one complex need to be placed on an appropriate point normally earth or machines ground So a lower disturbance...

Страница 18: ...n 4 Program numbers for parameterising of the input are not accessible Programming lock is activated Enter correct code 5 Err1 lights up in the 7 segment display Please contact the manufacturer if err...

Страница 19: ...ional disposal regulations and environmental regulations Batteries Batteries containing pollutants are marked with a sign consisting of a crossed out garbage can and the chemical symbol Cd Hg Li or Pb...

Страница 20: ...or measurement control and laboratory use Part 1 General requirements EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements EN IE...

Отзывы: