Filter 
The filter function "

Filt

" generates the sliding average value from the measured 

values. The following values are available (see section 6.2 Settings): 
 
 

1 / 2 / 4 / 8 / 16 / 32 / 64 

 
 
The filter value determines the dynamic behaviour of the indicated value: high 
values result in a slow display response. The filter is disabled if a filter value of "1" 
is selected. In other words, the indicated value is equal to the unfiltered measured 
value. 
 
The integrated step detector responds to a measured-value step change greater 
than approximately 6.25% of the upper range value. When a measured-value 
step change is detected, the actual measured value is displayed immediately. 

 
 
Contact Model 

The function of the transistor switching output is set in menu item "

Con, Co1 or 

Co2

". The switching function switches from 

 

no - N/O contact 

to 

 

nc - N/C 

to 

 

Fr – frequency 

(Con and Co1 only and 
for sensors with impulse 
output)  

 

and back. 

N/O contact means: contact closes when switching point is exceeded 
N/C means: contact opens when switching point is exceeded 
Frequency means: frequency output synchronized with vane frequency 
 
 

Current output 

The current output is selected in menu items  
 

"

S-C

"   Start current  indicated value < > 0(4) mA 

 

"

E-C

"   End current   indicated value < > 20 mA 

 

"

SCS

"   Start current selection (0-20 mA or 4-20 mA). 

The indicated value at which 0(4) mA flow is entered in menu item Start current. 
The indicated value at which 20 mA flow is entered in menu item End current.  
 
 

Change Code 

The change code option "

CCo

" secures the unit against unauthorised tempering. 

If the code is different from 000, the user must input the code immediately after 
entering the adjustment mode. 

 

Содержание **C3 Series

Страница 1: ...Operating Instruction Supplement for Compact Electronics Model C30R C30M C34P C34N ...

Страница 2: ...e 3 3 Electrical Connection 3 4 Programming 5 5 Maintenance 12 6 Technical Information 12 Manufactured and sold by Kobold Messring GmbH Nordring 22 24 D 65719 Hofheim Tel 49 0 6192 2990 Fax 49 0 6192 23398 E Mail info de kobold com Internet www kobold com ...

Страница 3: ...t the voltages in your plant correspond with the instrument voltages Make sure that the supply wires are de energized Connect the supply voltage and evaluation of both output signals to the plug connector PINs as shown in section 3 2 and 3 3 We recommend the use of wires with cross sectional area of min 0 25 mm Attention Incorrect wiring will lead to damage of the unit s electronics ...

Страница 4: ...30R C30M 3 3 Compact Electronics C34P C34N Terminals 3 and 5 are linked internally and can therefore be used either for the output signal or the power supply Vs GND GND 1 2 4 3 5 S witch out 2 S witch out 1 Vs GND GND 1 2 4 3 5 0 4 20 mA S witch out 1 ...

Страница 5: ...int SPo SP1 SP2 0 999 0 00 Hysteresis HYS 199 0 0 00 Window point duo Switching point 999 de activated Filter Filt 1 2 4 8 16 32 64 1 Contact type Con Co1 Co2 N O contact no N C nc or frequency Fr no N O contact Start current S C 000 999 000 End current E C 000 999 Upper range value Start current selection SCS 0 0 mA 4 4 mA 4 mA Change code CCo 000 999 000 Lower and upper range values of the flow ...

Страница 6: ...le Switching point SPo by pressing the key The structure shown below illustrates the universal routine for changing individual parameters from the main menu item 1 Digit setting 2 Digit setting 3 Digit setting Decimal point setting Choosed value storing or new setting to the next main menu item Storing ...

Страница 7: ...ntact 1 function N O N C Frequency Storing Filter 7 Levels Value setting Hysteresis Switching point 2 Swichting point 1 Code 3 sec Code entering Value setting Value setting Value setting Value setting Contact 2 function Value setting Only for sensors with impulse output ...

Страница 8: ...ysteresis Switching point 3 sec Code Start current 7sec 7sec Contact function Value setting Value setting Value setting Value setting Value setting 7 levels N O N C Frequency Value setting Value setting Storing End current Only for sensors with impulse output ...

Страница 9: ... be entered as a negative value in the menu HYS The default hysteresis value is zero However this can lead to confused switching when the measuring signal fluctuates around the switching point or window point This problem can be cured by increasing the hysteresis The hysteresis is based on the switching point and the window point switching point minus hysteresis window point plus hysteresis Exampl...

Страница 10: ...mits 99 l min 100 1 and 151 l min 150 1 then the electronics also remains in the activated switch state LED on Should the measured value exceed 151 l min or drop below 99 l min then the electronics switches back Switching performance The switching performance of the electronics is illustrated in the diagram below The contact closes N O contact when the switching point is exceeded or when the value...

Страница 11: ... switching output is set in menu item Con Co1 or Co2 The switching function switches from no N O contact to nc N C to Fr frequency Con and Co1 only and for sensors with impulse output and back N O contact means contact closes when switching point is exceeded N C means contact opens when switching point is exceeded Frequency means frequency output synchronized with vane frequency Current output The...

Страница 12: ...egment LED Display case stainless steel Analogue output 0 4 20 mA scalable C34 only Transistor output 1 2 semiconductor PNP or NPN set at the factory Frequency output 1 transistor output vane frequency see sensor Max switching current 300 mA Function N C N O contact programmable Setting with 2 buttons Supply 24 VDC 20 3 wire technology Electrical connection plug connector M12x1 ...

Отзывы: