PROBLEM
POSSIBLE CAUSE
SOLUTlON
1.- Not firmly plugged in.
1.- Check attachment plug.
2.- 8ad ON-OFF switch.
2.- Replace switch.
3.- Line cord open
3.- Replace cord.
A) Motor does not run
4.- Motor open
4.- Check motor and wiring.
1.- Dust filter bag c1osed.
1.- Clean filter bag.
2.- Hose or wand closed
2,- Clean obstruction.
3.- Motor slow
3.- Check carbon brushes.
4,- Tank full
4.- Empty tank.
5.- Float valve up.
5,- Check float valve.
B) Motor runs but cleaner
does not run pick-up
6.- Damaged motor base gasket or head gasket 6.- Check gaskets
1.- Worn carbon brushes.
1,- Replace carbon brushes.
C) Motor runs erratically
2.- Defective armature.
2.- Replace armature.