HRP05/HRP11/HRP17 Accu-Steer Pump-Set
Kobelt Manufacturing Co. Ltd.
Rev D
HRP07-HRP11-HRP17_MANUAL
17 of 28
7
T
ROUBLESHOOTING
If you encounter problems with the operation of your product, please refer to the trouble-
shooting suggestions before contacting Kobelt for assistance. If the steps below do not
resolve your issue, please reach out either Kobelt directly or our Dealers in your area.
Table 3: Common Solutions
Problem
(Issue encountered)
Cause
(What it means)
Corrective Action
(What to do)
HRP does not turn ON
No power to unit.
1.
Check that the breaker is ON and has
not tripped.
2.
Check that power is being output by
the Autopilot.
3.
Use a Mutli-meter to confirm if
power is present between the motor
leads when the Autopilot is
commanding motion.
Wheel feels soft
Air present in
Hydraulic System
1.
Bleed hydraulic system to remove
trapped air.
2.
Check for proper operation.
HRP turns in opposite
direction then
expected
Motor connection
leads are
backwards, O
R
, the
autopilot is
expecting the
reversed wiring
configuration.
1.
Shut off power to the unit.
2.
Disconnect the Red and Black wire
leads.
3.
Swap the lead connections and re-
connect.
4.
Check for proper operating direction.