![Kobelt 7166 Electric Helm Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/kobelt/7166-electric-helm/7166-electric-helm_owners-operation-installation-and-maintenance-manual_1982039011.webp)
Model 7166 Electric Helm
Kobelt Manufacturing Co. Ltd.
Rev A
mnl7166.docx
11 of 17
5
M
AINTENANCE
5.1
P
REVENTATIVE
M
AINTENANCE
•
Quarterly (4 times per year)
o
Visually inspect wire and cable insulation for splits or damage.
o
Ensure there is no visible corrosion on the unit.
•
Biennially (Once every 2 years)
o
Lubricate the detent track
o
Lubricate the gear teeth
o
Confirm all electrical screw terminals are secured.
5.2
L
UBRICATION
The track the detent runs along on the detent plate must be lubricated to prevent premature
wear. Use a grease with MoS
2
additives for best results. The following greases are approved:
Table 3: Approved Lubricants
EP Grease Brand
CHEVRON DELO MOLY 5% EP2
MOBIL XHP-322
SHELL S3 V460
5.3
R
ECOMMENDED
S
PARE
P
ARTS
No spare parts are recommended for this unit due to the sealed nature of its design.
When purchasing replacement parts refer to Appendix B: Parts List at the back of this manual
for Kobelt component Part Numbers.
It is recommended that any required service work on a Kobelt unit
be performed by a factory authorized service representative. Please
contact the nearest Kobelt authorized distributor for assistance.