KIMA00H1 (0204)
11
1.8
Shutdowns
Shutdown conditions are indicated by a red ALARM light on the
control panel, and an appropriate message on the graphic display. In
addition, an audible alarm sounds when an alarm occurs. The alarm
beeper may be silenced by pressing ACK/Bell Cancel on the alarm
page. The Bell Cancel does not reset the alarm. A "DRY" relay
contact is provided as a combined signal for remote indication if any
alarm occurs. A table of setpoints is located on page 22.
The GT Terminal indicates the following shutdown conditions:
a. High 1st Discharge Air Temperature (Shutdown)
Warning: HOT 1st Discharge (Prealarm)
Indicates a problem with the first compressor stage.
b. Warning: HOT 2nd Suction (Prealarm)
High 2nd Suction Air Temperature (Shutdown)
Indicates a problem with the intercooler or cooling air flow.
c. Warning: HOT 2nd Discharge (Prealarm)
High 2nd Discharge Air Temperature (Shutdown)
Indicates a problem with the second compressor stage or a
problem with the intercooler.
d. Warning: HOT Air Discharge (Prealarm)
High Discharge Air Temperature (Shutdown)
Indicates a problem with the aftercooler or cooling air flow.
e. Warning: HOT Lube OIL (Prealarm)
High Lube Oil Temperature (Shutdown)
Indicates a problem with the lube oil cooling system.
f. Low Lube Oil Pressure
Indicates low lube oil level in sump, lube oil pump failure, fouled
cooler or piping, clogged oil filter, or improper setting of the relief
valve.
g. Lube Oil Pump Motor Overload
Indicates continued over-current operation of the oil pump motor,
problem with lube oil pump or motor, or high oil pressure.
h. Cooling Fan Motor Overload
Indicates continued over-current operation of the cabinet cooling
fan motor, problem with fan or motor. Also check for obstructed
air flow into or out of the cabinet.
i. Compressor Drive Motor Overload
Indicates continued over-current operation of the drive motor for
the compressor, excessive discharge pressure or a problem with
either compressor stage.
j. High Cabinet Temperature
Indicates an obstruction of the cooling air flow.
k. High Discharge Air Pressure
Indicates a problem with the capacity control system.
l. Main Starter Failure
Indicates a problem with the main starter or controls.
Содержание KNW Series
Страница 4: ...KIMA00H1 0204 FIGURE 1 KOBELCO KNW SERIES MODEL A00 AIR COMPRESSOR ...
Страница 47: ...KIMA00H1 0204 43 Appendix A Daily Operating Record ...
Страница 49: ...KIMA00H1 0204 45 Appendix B Unit Dimensions Minimum Working Clearances TOP VIEW FRONT VIEW ...
Страница 50: ...KIMA00H1 0204 46 Appendix B cont Unit Dimensions and Field Connections SIDE VIEW REAR VIEW ...
Страница 51: ...KIMA00H1 0204 47 Appendix B cont Unit Dimensions Field Connections and Mounting ...
Страница 52: ...KIMA00H1 0204 48 ...