background image

 

 

What to Do In The Event Of a Range Top Grease Fire 

 

• 

SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner.  
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES.  If the flames do not go 
out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. 

• 

NEVER PICK UP A BURNING PAN – You May Get Burned. 

• 

DO NOT USE WATER, including wet dishcloths or towels – a steam blast will result. 

• 

Use an extinguisher ONLY if: 
a)  You have a Class A, B, C extinguisher and know how to operate it. 
b)  The fire is small and contained in the area where it started. 
c)  The fire department has been called. 
d)  You can fight the fire with your back to an exit. 

 

What to Do If You Smell Gas 

 

Extinguish any open flame. 

Do not try to turn on the lights or any type of appliance. 

Open all doors and windows to disperse the gas.  If you still smell gas, call the Gas Company and 
Fire Department right away. 

 

CAUTION

  

 

1)  For general ventilation use only.  Do not use to exhaust hazardous or explosive materials and vapors.   
2)  To reduce the risk of fire, use only metal ductwork.  Sufficient air is needed for proper combustion and 

exhausting of gases through the flue (chimney) to prevent back drafting. 

3)  Follow the heating equipment manufacturer’s guideline and safety standards such as those published 

by the National Fire Protection Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities. 

4)  Activating any switch on may cause ignition or an explosion. 
5)  Due to the size and weight of this hood, installation by 2 persons is recommended. 

 
 
 

 

 

 

ELECTRICAL SHOCK HAZARD – Can result in serious injury or death.  
Disconnect appliance from electric power before servicing.  If equipped, 
the fluorescent light bulb contains small amounts of mercury, which must 
be recycled or disposed of according to Local, State, and Federal Codes.

 

 
 

 

 
 
 
 
 

Содержание RA9230SQB-1

Страница 1: ...KOBE Brand Range Hood Model No RA9230SQB 1 30 RA9236SQB 1 36 RA9430SQB 1 30 RA9436SQB 1 36 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...

Страница 2: ...T INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shi...

Страница 3: ...NCE 10 SPECIFICATIONS 11 MEASUREMENTS DIAGRAMS 12 PARTS LIST 15 CIRCUIT DIAGRAM 17 TROUBLE SHOOTING 18 WARRANTY 19 PRODUCT REGISTRATION 21 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R I...

Страница 4: ...atment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automati...

Страница 5: ...ou still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk...

Страница 6: ...Quick Reference Guide D Baffle Filter x 2 30 hood x 3 36 hood E Hood Mounting Bracket F 6 Round Plastic Collar G Duct Cover Mounting Bracket H Screws package A B C D Knob attached to baffle filter E...

Страница 7: ...rence Guide D Baffle Filter x 2 30 hood x 3 36 hood E Hood Mounting Bracket F 6 Round Plastic Collar G Duct Cover Mounting Bracket H Screws package A B C D Knob attached to baffle filter E Pre install...

Страница 8: ...B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of Duct Cover F D F Height of the Hood Installation A B C SAFE...

Страница 9: ...re back wall frame with cross framing lumber for secure installation Using references on Table 1 and measurements on page 12 13 decide the level of the lumber Refer to Figure 2 Hood Installation CAUTI...

Страница 10: ...llation 4 Mark the position of the Duct Cover Mounting Bracket G Use reference E from Table 1 and measurements on page 12 13 Attach and secure Duct Cover Mounting Bracket G with two screws not provide...

Страница 11: ...button a second time Light Control Press button to turn LED lights ON Each press of button will cycle the light intensity through Bright Medium Bright Dim and OFF Lights are controlled independently...

Страница 12: ...e press and hold button until icon no longer appears in the LED Display NOTE Pressing button while ECO Mode is active will activate the regular fan function and the speed will be displayed in LED Disp...

Страница 13: ...b off any stubborn spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere...

Страница 14: ...D DIMENSION W x D x H RA9230SQB 1 29 3 4 x 20 1 2 x 12 3 16 RA9236SQB 1 35 1 4 x 20 1 2 x 12 3 16 RA9430SQB 1 29 3 4 x 20 1 2 x 12 3 16 RA9436SQB 1 35 1 4 x 20 1 2 x 12 3 16 OPTIONAL ACCESSORIES W x D...

Страница 15: ...12 MEASUREMENTS DIAGRAMS All inch measurements are converted from millimeters Inch measurements are estimated All measurements in are millimeters MODEL NO RA9230SQB 1 30 RA9236SQB 1 36...

Страница 16: ...13 All inch measurements are converted from millimeters Inch measurements are estimated All measurements in are millimeters MODEL NO RA9430SQB 1 30 RA9436SQB 1 36...

Страница 17: ...14...

Страница 18: ...astic Exhaust L1 0505 0003 5 Hood Casing RA9230SQB 1 10 9230B RA9236SQB 1 10 9236B 6 LED Light 3W L1 0403 0301 7 Control Panel L1 0404 6001 A 8 Control Panel Support L1 0207 1630 9 Blower System L1 03...

Страница 19: ...und Plastic Exhaust L1 0505 0003 5 Hood Casing RA9430SQB 1 10 9430B RA9436SQB 1 10 9436B 6 LED Light 3W L1 0403 0301 7 Control Panel L1 0404 6001 A 8 Control Panel Support L1 0207 1630 9 Blower System...

Страница 20: ...17 CIRCUIT DIAGRAM MODEL NO RA9230SQB 1 30 RA9236SQB 1 36 RA9430SQB 1 30 RA9436SQB 1 36...

Страница 21: ...ng bracket The motor is working but the lights are not working LED light fixture s is defective Replace LED light fixture s The light wiring s is loose Check wire continuity from processor board to li...

Страница 22: ...nclude but are not limited to Service technician travel charges if the requested service location is 30 miles out of KOBE s authorized service area Parts shipping expenses Un installation of defective...

Страница 23: ...ify for warranty service you must 1 Have the ORIGINAL proof of purchase 2 Be the ORIGINAL purchaser of the product 3 Have the model number 4 Have the serial number 5 Have a description of the nature o...

Страница 24: ...purpose 1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center USA ONLY Toll Free 1 855 800 KOBE 5623 Email kobe adcoservice com For servic...

Страница 25: ...ommand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votre pro...

Отзывы: