background image

 

 

                                      
                                 

KOBE Range Hoods 
 

Deluxe Series 

 

RA02 Series 

Model No.

 

RA0230SQB-DC-5 / RA0230SQB-DC24-5 / RA0230SQB-DC48-5 (30”) 
RA0236SQB-DC-5 / RA0236SQB-DC24-5 / RA0236SQB-DC48-5 (36”) 
RA0242SQB-DC-5 / RA0242SQB-DC24-5 / RA0242SQB-DC48-5 (42”) 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLATION INSTRUCTIONS 

AND OPERATION MANUAL

 

Содержание RA0230SQB-DC-5

Страница 1: ...ries RA02 Series Model No RA0230SQB DC 5 RA0230SQB DC24 5 RA0230SQB DC48 5 30 RA0236SQB DC 5 RA0236SQB DC24 5 RA0236SQB DC48 5 36 RA0242SQB DC 5 RA0242SQB DC24 5 RA0242SQB DC48 5 42 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL ...

Страница 2: ...L PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shipping damages cosmetic damages or defects 4 For other issues email customer service koberangehoods com or call 1 626 775 8880 ext 103 toll free 1 877 289 5623 NO RETURN NO REFUND NO EXCHANGE IF 1 PRODUCT HAS BEEN INSTALLED 2 KNOCK OUT HOLE...

Страница 3: ...NANCE 9 SPECIFICATIONS 10 MEASUREMENTS DIAGRAMS 12 PARTS LIST 12 CIRCUIT DIAGRAM 16 TROUBLE SHOOTING 17 WARRANTY 18 PRODUCT REGISTRATION 20 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S ...

Страница 4: ...treatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range h...

Страница 5: ...s If you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney to prevent back drafting 3 Follow the heating equipment manufactu...

Страница 6: ...Duct Cover Model No RA02DC 1 L Wire Cap M Screws Package A B C D E F G H I J K L M Inner Duct Extension RA02DC 24 1 Included in RA02 SQB DC24 5 and SQB DC48 5 N Inner Duct Extension Model No RA02DC 24 1 O Duct Cover Mounting Bracket P Screws Package N O P Outer Duct Extension RA02DC 24 Included in RA02 SQB DC48 5 Only Q Outer Duct Extension Model No RA02DC 24 Q FOR MORE INFORMATION PLEASE VISIT OU...

Страница 7: ... to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom 30 36 Hood Recommended 27 to 30 42 Hood Recommended 30 to 36 A B D E D Height of Hood E Height of Duct Cover SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTR...

Страница 8: ...ay reduce the performance of the hood Temporarily wire the hood to test for proper operation before installing Important Peel protective film off the hood and the duct cover if any If necessary prepare back wall frame with cross framing lumber for secure installation Refer to Table 2 and measurements on Page 12 to decide the level of the lumber Figure 2 Loosen hood mounting brackets at the back of...

Страница 9: ...ower Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK THIS RANGE HOOD MUST BE PROPERLY GROUNDED MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY 5 Connect the electrical wires Connect three wires b...

Страница 10: ...s included to attach duct cover to hood Refer to Figure 6 Install Accessories 8 Attach oil tunnel Refer to Figure 7 9 Refer to Figure 23 Slide the baffle filter into the hood Push the baffle filter upward Slide forward Pull downward Fit into place 10 Repeat until all baffle filters and spacers are resting against oil tunnel Refer to page 8 Final Assembly 11 Turn power ON in control panel Check all...

Страница 11: ...t Control Speed Control Refer to Figure 9 Figure 9 Note For best results turn hood to QuietMode prior to preparation or cooking to establish airflow in the kitchen Adjust speed as needed Rotate the Speed Control clockwise to cycle from QuietMode Low High and Off and rotate counterclockwise to cycle from High Low QuietMode and Off Rotate the Light Control clockwise to turn on the light ...

Страница 12: ...slightly damp towel to get rid of any cleaning solution Use dry soft towel to dry the hood 3 To bring the glow back into a stainless steel finish use a stainless steel cleaner 4 DO NOT allow deposits to remain for long periods of time 5 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust 6 DO NOT allow salt solutions disinfectants bleaches or ...

Страница 13: ...320W 2 86A RA0242SQB DC24 5 350W 3A RA0230SQB DC48 5 320W 2 86A RA0236SQB DC48 5 320W 2 86A RA0242SQB DC48 5 350W 3A VOLTAGE 120V 60Hz NUMBER OF BLOWER 1 30 36 2 42 DESIGN 18 Gauge Seamless Satin Finish FAN TYPE CENTRIFUGAL Squirrel Cage EXHAUST Top 6 Round 30 36 Top 8 Round 42 CONTROLS Rotary Switch LIGHTS 3 Watt LED x 2 30 36 3 Watt LED x 3 42 HOOD DIMENSION W x D x H RA0230SQB DC 5 29 3 4 x 24 ...

Страница 14: ...2 HOOD WEIGHT lbs Net Gross RA0230SQB DC 5 55 67 RA0236SQB DC 5 60 74 RA0242SQB DC 5 75 91 RA02DC 1 5 7 SPEED QuietMode Low High SINGLE BLOWER RA0230SQB DC 5 RA0236SQB DC 5 RA0230SQB DC24 5 RA0236SQB DC24 5 RA0230SQB DC48 5 RA0236SQB DC48 5 Air Capacity cfm 290 550 720 Sone 1 8 4 7 5 4 DUAL BLOWERS RA0242SQB DC 5 RA0242SQB DC24 5 RA0242SQB DC48 5 Air Capacity cfm 450 700 1100 Sone 2 5 6 0 8 0 One ...

Страница 15: ... measurements in are millimeters PARTS LIST MODEL NO RA0230SQB DC 5 30 RA0236SQB DC 5 36 RA0242SQB DC 5 42 Inner Duct Extension Model No RA02DC 24 1 Baffle Filter for RA02 SQB 5 Series Outer Duct Extension Model No RA02DC 24 Included in RA02 SQB DC24 5 and SQB DC48 5 Series Included in RA02 SQB DC48 5 Series only ...

Страница 16: ...il Tunnel RA0242SQB DC 5 B101 9142 14A 7 Light Panel RA0230SQB DC 5 B101 0230 06 RA0236SQB DC 5 B101 0236 06 RA0242SQB DC 5 B101 0242 06 8 Blower System RA0230SQB DC 5 RA0236SQB DC 5 X5 L1 0302 0120 802RO RA0242SQB DC 5 X5 L1 0302 0120 802RE 8A Motor Support RA0242SQB DC 5 L1 0233 0242 9 Capacitor x 1PCS RA0230SQB DC 5 RA0236SQB DC 5 L1 0401 0120 24 Capacitor x 2PCS RA0242SQB DC 5 L1 0401 0120 24 ...

Страница 17: ...14 Model No RA0230SQB 5 RA0230SQB DC24 5 RA0230SQB DC48 5 30 RA0236SQB 5 RA0236SQB DC24 5 RA0236SQB DC48 5 36 ...

Страница 18: ...15 Model No RA0242SQB 5 RA0242SQB DC24 5 RA0242SQB DC48 5 42 ...

Страница 19: ...16 CIRCUIT DIAGRAM MODEL NO RA0230SQB DC 5 RA0230SQB DC24 5 RA0230SQB DC48 5 30 RA0236SQB DC 5 RA0236SQB DC24 5 RA0236SQB DC48 5 36 MODEL NO RA0242SQB DC 5 RA0242SQB DC24 5 RA0242SQB DC48 5 42 ...

Страница 20: ... continuity from light transformer to LED light housing s Light transformer is defective Check power input and power output on the light transformer If it s needed replace the light transformer The control panel is defective Replace the control panel The range hood is not venting out correctly The range hood is installed outside of the manufacture recommended clearance Adjust the clearance between...

Страница 21: ...free of charge that failed due to manufacturing defects Consumable parts such as lights bulbs filters fuses and oil cups are not covered by this warranty WHAT IS COVERED This warranty is valid in the United States and Canada It is non transferable and applies only to the original purchaser and does not extend to subsequent owner of this product In Hawaii Alaska and Canada this warranty is limited ...

Страница 22: ...maged due to negligence misuse abuse accident If we determine that the warranty exclusions listed above applies or if you fail to provide all necessary documentation for warranty service you will be responsible for all expenses associated with the requested service including parts labor shipping travelling and any other expense related to the service request TO REQUEST WARRANTY SERVICE PLEASE CONT...

Страница 23: ...del No 3 Serial No For warranty service or spare parts purchase in US contact KOBE Service Center Email best customer service koberangehoods com Phone 1 626 775 8880 ext 103 Toll Free 1 877 BUY KOBE 289 5623 For Warranty service or spare parts purchase in Canada contact Email best customer service koberangehoods com Toll Free 1 626 775 8880 ext 103 Your notes ...

Страница 24: ...mandé d utiliser cette hotte à l étranger puisque l alimentation électrique pourrait ne pas être compatible et enfreindre le code de l électricité de ce pays L usage de la hotte KOBE à l étranger est à votre propre risque et la garantie sera annulée Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE UU y CANADÁ No recomendamos la utilización de esta campana en el...