background image

 

4. 

Secure  and  tighten  the  mounting  screws.  
CAUTION:  MAKE  SURE  THE  HOOD  IS 
SECURE BEFORE RELEASING. 

 

Ductwork Installation 

 
5. 

Using  Reference  E  from  Table  1  and 
measurements  on  Page

 

11,  mark  the 

leveling  point  for  duct  cover-mounting 
bracket.  

6. 

Secure  the  duct  cover-mounting  bracket 
to the wall with two screws (not provided).  
(Figure  6)    Make  sure  all  screws  are 
tightened.    NOTE:  Inner  duct  cover  will 
cover the duct cover-mounting bracket. 

7. 

Use aluminum or steel pipe (not provided) 
to connect the plastic exhaust on the hood 
to  the ductwork  above.    Use  duct  tape  to 
ensure all joints are secure and air tight as 
shown in Figure 7. 

 

Wiring to Power Supply 

SAFETY WARNING 

RISK  OF  ELECTRICAL  SHOCK.    THIS 
RANGE 

HOOD 

MUST 

BE 

PROPERLY 

GROUNDED.    MAKE  SURE  THIS  IS  DONE 
BY 

SPECIALIZED 

ELECTRICIAN 

IN 

ACCORDANCE  WITH  ALL  APPLICABLE 
NATIONAL 

AND 

LOCAL 

ELECTRICAL 

CODES.    BEFORE  CONNECTING  WIRES, 
SWITCH  POWER  OFF  AT  SERVICE  PANEL 
AND  LOCK  SERVICE  PANEL  TO  PREVENT 
POWER  FROM  BEING  SWITCHED  ON 
ACCIDENTALLY. 
.   
8. 

Connect  three  wires  (black,  white  and 
green)  to  house  wires  and  cap  with  wire 
connectors.    Connect  according  to  color:  
black  to  black,  white  to  white,  and  green 
to green as shown in Figure 8 

9. 

Test  the  operation  of  the  hood  before 
performing  the  next  step.    Make  sure 
power is supplied to the hood. 

 

Duct Cover Installation 

 
10.  Slide  inner  duct  cover up 2  inches  before 

sliding  entire  duct  cover  onto  the  hood.  
(Figure 9) 

11.  Align  the  inner  duct  cover  to  the  duct 

cover-mounting bracket.  Secure  

 
 

Figure 5 

 

 
 
 
 
 
 
 
 
 

 
 

Figure 6 

 

 
 
 
 
 
 
 
 
 

 
 

Figure 7 

 

 
 
 
 
 
 
 
 
 

 

 

Figure 8 

 

 
 
 
 
 
 
 
 
 

 

 

Содержание RA-094

Страница 1: ...KOBE Brand Range Hood Model No RA9430SQB RA9436SQB RA 094 SERIES INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...

Страница 2: ...Operation Instructions 8 Maintenance 9 Specifications 10 Measurements Diagrams 11 Parts List 12 Circuit Diagram 14 Disclaimer 15 Warranty 16 Product Registration 18 READ ALL INSTRUCTIONS CAREFULLY BEF...

Страница 3: ...installation improper use mistreatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS...

Страница 4: ...not try to turn on the lights or any type of appliance Open all doors and windows to disperse the gas If you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general...

Страница 5: ...d Box RA9430SQB Model No RA9430SQB RA9436SQB KOBE Range Hood 1 Warranty Registration Card 1 Instructions Manual 1 Hood Mounting Bracket 2 Screws Package 1 Attached to Hood Baffle Filter 2 Baffle Handl...

Страница 6: ...iling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Recommended 27 to 30 D Height of Hood E Height of the Hood Installation A B C F Height of Duct Cover...

Страница 7: ...re installation Refer to Table 1 and measurements on Page 11 to decide the level of the lumber Figure 2 Loosen hood mounting brackets at the back of the hood adjust brackets and tighten screws as show...

Страница 8: ...ARNING RISK OF ELECTRICAL SHOCK THIS RANGE HOOD MUST BE PROPERLY GROUNDED MAKE SURE THIS IS DONE BY A SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES BEFO...

Страница 9: ...hood with four 4x8 mm screws provided Install Accessories 13 Place baffle filters underneath the hood Refer to Figure 10 Final Assembly 14 Turn power ON in control panel Check all lights and fan opera...

Страница 10: ...will start on Low speed Each press of the Speed Control button will cycle through the various speeds Press Speed Control A button to cycle from Low Medium High or QuietMode Press Speed Control B butt...

Страница 11: ...salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with wa...

Страница 12: ...OD DIMENSION W x D x H RA9430SQB 29 3 4 x 20 1 2 x 12 1 4 RA9436SQB 35 1 4 x 20 1 2 x 12 1 4 OPTIONAL ACCESSORIES W x D x H 1 Model No RA0931DC 1 Piece Extension Duct Cover for 9 10 Ceiling 2 Model No...

Страница 13: ...11 MEASUREMENTS DIAGRAMS Front View Bottom View 36 Hood 30 Hood...

Страница 14: ...Casing RA9430SQB RA 2530 A RA9436SQB RA 25900 A 8 Wiring Box C1 0231 2590 9 Halogen Lights 12V 20W C1 0403 0001 10 Air Chamber Motor C1 0302 A120 01 11 Safety Screen C1 0602 0103 12 Control Panel Sup...

Страница 15: ...13 MODEL NO RA9430SQB RA9436SQB...

Страница 16: ...14 CIRCUIT DIAGRAM MODEL NO RA9430SQB RA9436SQB...

Страница 17: ...Contact your local KOBE dealer or distributor or call KOBE for the time limit CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS NOTE ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR FACTORY...

Страница 18: ...ertificate 1 This warranty applies only a within U S A and Canada b to range hoods used for PRIVATE SINGLE FAMILY USE if used for COMMERCIAL or MULTIPLE FAMILY USE or other purposes warranty will be v...

Страница 19: ...QUENTIAL DAMAGE The warrantor is not responsible for any consequential damage SOME STATES DO NOT ALLOW THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU IMPLIED WARRANT...

Страница 20: ...iration of the original purchaser s warranty See warranty section for complete warranty coverage information This appliance has been manufactured tested and inspected to the standards required by KOBE...

Страница 21: ...com This KOBE hood is manufactured for use in the USA and CANADA only We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that...

Отзывы: