Preparation Before Installation 

NOTE:    TO  AVOID  DAMAGE  TO  YOUR  HOOD,  PREVENT 

DEBRIS FROM ENTERING THE VENT OPENING. 

 

Decide the location of the venting pipe from the hood to the 
outside.  Refer to Figure 1. 

 

A straight, short vent run will allow the hood to perform more 
efficiently. 

 

Try  to  avoid  as  many  transitions,  elbows,  and  long  run  as 
possible.  This may reduce the performance of the hood. 

 

Temporarily wire the hood to test for proper operation before 
installing. 

 

Important:  Peel protective film off the hood, if any. 

 

Use duct tape to seal joints between pipe sections. 

 

CAUTION

:  If moving the cooking range is necessary to 

install the hood, turn off the power in an electric range at 
the main electrical box.  SHUT OFF THE GAS BEFORE 
MOVING A GAS RANGE.  And use a protective covering 
to protect cooktop and/or countertop from damage. 

Custom Hood Preparation 

1.  The  custom  hood  frame  must  be  designed  based  on  the 

shape  and the  weight  of the  hood.   Refer to  Measurements 
and Diagrams of hood on Page 13-15.   

2.  A  sturdy  base  (3/4  inch  thick  plywood  recommended)  is 

needed to sustain the weight of hood. 

3.  It  is  recommended  to  install  front  &  rear  stud  support  (not 

included).    Refer  to  Figure  2.    For  safety  purposes,  extra 
installation  holes  on  the  side  of  the  hood  are  provided.  
Prepare the side stud support if needed.   

4.  Determine and mark the centerlines on the base of the wood 

frame where the hood will be installed.  

5.  Determine  the  proper  location  for  the  Power  Supply  Cable.  

Make a wiring access hole using a drill bit.   Install the wire 
cable and seal the gap around hole. 

6.  Cut out the opening where the hood will be installed. (Refer to 

Figure 3 for appropriate dimensions based on width of hood.) 

Wiring to Power Supply  

CAUTION

:  If moving the cooking range is necessary to 

install the hood, turn off the power in an electric range at 
the  main  electrical  box.    SHUT  OFF  THE  GAS  BEFORE 
MOVING A GAS RANGE. RISK OF ELECTRICAL SHOCK.   

THIS RANGE HOOD MUST BE PROPERLY GROUNDED.  
MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN 
IN  ACCORDANCE  WITH  ALL  APPLICABLE  NATIONAL 
AND 

LOCAL 

ELECTRICAL 

CODES. 

 

BEFORE 

CONNECTING  WIRES,  SWITCH  POWER  OFF  AT 
SERVICE  PANEL  AND  LOCK  SERVICE  PANEL  TO 
PREVENT
  POWER  FROM  BEING  SWITCHED  ON 
ACCIDENTALLY. 

 
7.  Temporarily wire the hood to test for proper operation before 

Figure 1 
 
 
 
 
 
 
 
                       
 
 
 
 
 
Figure 2 

                 

 
 
 
 
 
 
 

 

 
Figure 3 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 
 
 

 

 

 

IN2636SQB-1100-5A (36”) 

IN2642SQB-1100-5A (42”) 

IN2648SQB-1100-5A (48”) 

Содержание Deluxe IN2636SQB-1100-5A

Страница 1: ...KOBE Range Hoods Deluxe Series IN26 SQB 1100 5A Series Model No IN2636SQB 1100 5A 36 IN2642SQB 1100 5A 42 IN2648SQB 1100 5A 48 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...

Страница 2: ...OBLEM 1 DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replaceme...

Страница 3: ...E 9 SPECIFICATIONS 10 MEASUREMENTS DIAGRAMS 11 PARTS LIST 16 CIRCUIT DIAGRAM 16 TROUBLE SHOOTING 17 WARRANTY 18 WARRANTY INFORMATION FORM 20 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R...

Страница 4: ...atment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automati...

Страница 5: ...ou still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk...

Страница 6: ...x A KOBE Range Hood B Warranty Registration Card C Quick Reference Guide D Baffle Filter x 2 36 x 3 42 48 E Oil Tunnel F Stainless Steel Spacer x 2 For 36 48 G Power Cord H Twist on Wire Cap I Screws...

Страница 7: ...NSERT TABLE 1 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Height of Counter Top to Wood Frame Bottom Minimum 27 to 30 D Height of Wood Frame SAFETY WARNING HOOD MAY HAV...

Страница 8: ...of hood 3 It is recommended to install front rear stud support not included Refer to Figure 2 For safety purposes extra installation holes on the side of the hood are provided Prepare the side stud su...

Страница 9: ...SE DAMAGE TO THE HOOD 13 Remove the light panel by removing screws located at the bottom of the hood 8 screws for 36 42 and 11 screws for 48 Refer to Figure 5 as reference Carefully remove the light s...

Страница 10: ...e Delay Shutoff To activate the 3 minute delay shutoff press and hold the power button for about 3 seconds Once the delay shutoff has been activated the LED display will flash and the fan speed will c...

Страница 11: ...lash while ECO Mode is operating on QuietMode To deactivate press and hold the ECO button until the E icon no longer appears in the LED display NOTE Press the power button while ECO Mode is active wil...

Страница 12: ...ft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5...

Страница 13: ...e Control Sold Separately LIGHTS LED Lights 3W x 2 36 3 Level Lighting LED Lights 3W x 3 42 48 3 Level Lighting HOOD DIMENSION W X D X H IN2636SQB 1100 5A 34 3 8 x 22 1 2 x 12 IN2642SQB 1100 5A 40 3 8...

Страница 14: ...ENTS DIAGRAMS All are in millimeter All inch measurements are converted from millimeters Inch measurements are estimated MODEL NO IN2636SQB 1100 5A 36 IN2642SQB 1100 5A 42 IN2648SQB 1100 5A 48 Side Vi...

Страница 15: ...14 Bottom View MODEL NO IN2636SQB 1100 5A 36 MODEL NO IN2642SQB 1100 5A 42 MODEL NO IN2648SQB 1100 5A 48...

Страница 16: ...15 Front View MODEL NO IN2636SQB 1100 5A 36 MODEL NO IN2642SQB 1100 5A 42 MODEL NO IN2648SQB 1100 5A 48...

Страница 17: ...0302 0120 590RE Blower System Left X5 L1 0302 0120 590RE 9 Bottom Casing IN2636SQB 1100 5A B101 2636 09 12 IN2642SQB 1100 5A B101 2642 09 12 IN2648SQB 1100 5A B101 2648 09 12 10 Baffle Filter Support...

Страница 18: ...17 MODEL NO IN2636SQB 1100 5A 36 IN2642SQB 1100 5A 42 IN2648SQB 1100 5A 48...

Страница 19: ...18 CIRCUIT DIAGRAM MODEL NO IN2636SQB 1100 5A 36 IN2642SQB 1100 5A 42 IN2648SQB 1100 5A 48...

Страница 20: ...s are not working Hood is not secured in place Check the installation of hood tighten the mounting bracket LED light fixture s is defective Replace LED light fixture s The light wiring s is loose Chec...

Страница 21: ...and oil cups are not covered by this warranty WHAT IS COVERED This warranty is valid in the United States and Canada It is non transferable and applies only to the original purchaser and does not ext...

Страница 22: ...lies or if you fail to provide all necessary documentation for warranty service you will be responsible for all expenses associated with the requested service including parts labor shipping travelling...

Страница 23: ...odel No 3 Serial No For warranty service or spare parts purchase in US contact KOBE Service Center Email best customer service koberangehoods com Phone 1 626 775 8880 ext 103 Toll Free 1 877 BUY KOBE...

Страница 24: ...mand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votre propr...

Отзывы: