background image

 
 

 IMPORTANT SAFETY INSTRUCTIONS  

 

- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - 

 

WARNING

TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRIC  SHOCK  OR  PERSONAL 
INJURY, OBSERVE THE FOLLOWING:

 

 

1)  Installation and electrical wiring must be done by qualified professionals and in accordance with all 

applicable codes and standards, including fire-rated construction. 

2)  When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden 

utilities. 

3)  Ducted fans must be vented to the outside. 

a)  Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE 

PANEL. 

b)  Clean  all  grease  laden  surfaces  frequently.    To  reduce  the  risk  of  fire  and  to  disperse  air 

properly, make sure to vent air outside.   DO NOT vent exhaust air into wall spaces, attics, crawl 
spaces or garages. 

 

NOT E 

This  warranty  is  void without  an  authorized  agent’s  receipt  or  if  unit  is 
damaged due to misuse, poor installation, improper use, mistreatment, 
negligence  or  any  other  circumstances  beyond  the  control  of  KOBE 
authorized  agents.    Any  repair  carried  out  without  the  supervision  of 
KOBE authorized agents will automatically void the warranty. 

 

 

 

 

KOBE  will  not  be  held  responsible  for  any  damages  to  personal 
property or real estate or any bodily injuries whether caused directly or 
indirectly by the range hood. 

 

WARNING

TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE 
TOP GREASE FIRE: 

 

1.  Keep  all  fan,  baffle/spacer/filter/oil  tunnel/oil  container  and  grease-laden  surfaces  clean.    Grease 

should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container. 

2.  Always turn hood ON when cooking. 
3.  Use high settings on cooking range ONLY when necessary.   
4.  Do not leave cooking range unattended when cooking. 
5.  Always use cookware and utensils appropriate for the type and amount of food prepared. 
6.  Use this unit only in the manner intended by the manufacturer. 
7.  Before  servicing,  switch  power  off  at  service  panel  and  lock  service  panel  (if  possible)  to  prevent 

power from switching on accidentally. 

8.  Clean ventilating fan frequently. 

 
 
 
 
 
 
 
 

 

Содержание Brillia SeriesOVS-CHX7930SQB-40 (30")

Страница 1: ...KOBE Range Hoods Brillia Series Model No CHX7930SQB 1 30 CHX7936SQB 1 36 USER MANUAL INSTALLATION GUIDE...

Страница 2: ...HERE IS ANY PROBLEM 1 DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Call 1 877 BUY KOBE 289 5623...

Страница 3: ...ANCE 14 SPECIFICATIONS 15 MEASUREMENTS DIAGRAMS 16 PARTS LIST 18 CIRCUIT DIAGRAM 20 TROUBLE SHOOTING 21 WARRANTY 22 PRODUCT REGISTRATION 24 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R...

Страница 4: ...mproper use mistreatment negligence or any other circumstances beyond the control of KOBE authorized agents Any repair carried out without the supervision of KOBE authorized agents will automatically...

Страница 5: ...ou still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk...

Страница 6: ...haust Plate x 1 F Baffle Filters x 2 G Spacers x 2 H 6 Round Plastic Exhaust x 1 I Oil Tunnel x 1 A B C D E F G H I J Adjustable Duct Cover K Screws Package L Duct Cover Mounting Bracket M Duct Cover...

Страница 7: ...ing B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVER TABL...

Страница 8: ...SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Conten...

Страница 9: ...el protective film off the hood if any Use duct tape to seal joints between pipe sections For installing under the cabinet with recessed bottom attach 4 inch wide wood filler strips not included on ea...

Страница 10: ...ange is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE And use a protective covering to protect cooktop and...

Страница 11: ...ss Steel Spacers E Angle baffle filter toward back of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits...

Страница 12: ...or secure installation Using references on Table 2 and measurements on page 16 17 decide the level of the lumber Refer to Figure 10 Vent option installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIG...

Страница 13: ...Figure 14 Hood Installation CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GA...

Страница 14: ...ouse wires and cap with wire connectors 9 Store wires in the wiring box Ductwork Installation 10 Use steel pipe to connect the exhaust on the hood to the ductwork Use duct tape to make all joints secu...

Страница 15: ...of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting position Refer to Figure 20 17 For Sta...

Страница 16: ...r cooking and keep fans running while cooking Adjust speed as needed To operate the fan function Press button to choose from speed o Q QuietMode speed o L Low speed o H High speed Press OFF to turn fa...

Страница 17: ...orn spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface...

Страница 18: ...HOOD DIMENSION W x D x H CHX7930SQB 1 29 3 4 x 22 x 9 1 16 CHX7936SQB 1 35 3 4 x 22 x 9 1 16 OPTIONAL ACCESSORIES W x D x H 1 Two Piece Adjustable Duct Cover CH1120DC 1 11 13 16 x 10 7 16 x 22 41 2 30...

Страница 19: ...s are converted from millimeters Inch measurements are estimated All measurements in are millimeters MODEL NO CHX7930SQB 1 30 CHX7936SQB 1 36 FOR UNDER THE CABINET 30 Knockout Holes A 36 Knockout Hole...

Страница 20: ...17 Hood Mounting Bracket Duct Cover Mounting Bracket Duct Cover Support...

Страница 21: ...002 A 4 3 1 4 x10 Vent Cover L1 0241 0002 B 5 6 Round Plastic Collar L1 0505 0002 6 LED Light Fixture 3W L1 0403 0301 7 Control Unit L1 0405 0301 8 Capacitor 3 5uf 3 5uF 350V L1 0401 0120 03 9 Motor 1...

Страница 22: ...19 MODEL NO CHX7930SQB 1 30 CHX7936SQB 1 36...

Страница 23: ...20 CIRCUIT DIAGRAM MODEL NO CHX7930SQB 1 30 CHX7936SQB 1 36...

Страница 24: ...eplace LED light fixture s The light wiring s is loose Check wire continuity from Control Panel to LED Driver to LED light fixture s The control panel is defective Replace the control panel The range...

Страница 25: ...ch include but are not limited to Service technician travel charges if the requested service location is 30 miles out of KOBE s authorized service area Parts shipping expenses Un installation of defec...

Страница 26: ...ualify for warranty service you must 1 Have the ORIGINAL proof of purchase 2 Be the ORIGINAL purchaser of the product 3 Have the model number 4 Have the serial number 5 Have a description of the natur...

Страница 27: ...purpose 1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center USA ONLY Toll Free 1 855 800 KOBE 5623 Email kobe adcoservice com For servic...

Страница 28: ...au Canada seulement Nous ne recommandons pas d utiliser cette hotte l tranger que l alimentation peut ne pas tre compatible et peut violer le code de l lectricit de ce pays L utilisation de ce capot l...

Отзывы: