1.GENERAL DESCRIPTIONS 

WEI uses high reliability, good accuracy weighing devices, including wireless weighing indicator, high 

precision load cell and the most advanced ∆-∑ type A / D converter.  

WEI  Wireless  indicator  is  a  wireless  industrial  weighing  indicator  that  can  communicate  up  to  100 

meters in an open area designed especially for axle scales, cranes and dynamometers. 

WEI, which can be connected to 16 different load cells, can display all incoming weight information 

individually and in total on the graphic display. 

8 load cells (350 Ohm) can be connected to the wireless transmitter module it works with. 

Tensile and breakout tests can be performed with the Peak hold feature.  

When more than one balance is connected, it can zero and tare each scale separately. 

It can be connected to computers and printers with RS232 output.  

2. TECHNICIAL SPECIFICATIONS 

• 

Display 128x64 Dot Matrix GLCD  

• 

6 status indicators 

• 

Keypad 13 functions  

• 

ADC ∆-∑ Delta-Sigma 24 bits  

• 

A / D conversion speed 10 times/second  

• 

Supply voltage 5V DC  

• 

7.4V/2500mAH rechargeable lithium battery 

• 

8.4V/1A Charger Adapter 

• 

Radio Frequency 433MHZ  

• 

Wireless transmission distance 100m 

• 

Division 1/2/5/10/20/50/100  

• 

Filtering 5-Step Digital  

• 

RS232, Baud Rate 9600  

• 

Operating temperature -10°C~45°C  

 

 

 

Содержание WEI

Страница 1: ...WEI WIRELESS INDICATOR USER MANUAL...

Страница 2: ...CONTENTS 1 General Description 2 Technical Specifications 3 Description of Function Keys 4 Use of the Device 5 Menular Login 6 Menu Tree...

Страница 3: ...play 8 load cells 350 Ohm can be connected to the wireless transmitter module it works with Tensile and breakout tests can be performed with the Peak hold feature When more than one balance is connect...

Страница 4: ...he printer It is used to enter the menus and to switch the menus Enters the Peak menu Keeps the current peak value of the weighing The desired scale can be selected with the up arrow or down arrow Del...

Страница 5: ...eight data has become steady state 3 Displaying the Tare icon shows the net weight of the weigh weight data 4 The display of the M symbol indicates that the weighing weight data has been saved 5 This...

Страница 6: ...the key to enter the reset menu Group reset or single reset is selected to reset the weighing If group reset is selected all of the scales are reset If single reset is selected the desired scale can...

Страница 7: ...e screen to the current weight value Press ESC key to exit the menu and return to the main display After exiting this menu the captured peak value will not be lost 4 5 TARE SCREENING Press the key to...

Страница 8: ...e printing format to be taken from the printer is selected according to the product used These formats are separate for Dynamometer and Axle Scale WEIGHT REPORT WEIGHT 1 200 kg Date 23 03 2021 Time 08...

Страница 9: ...value is selected as 0001 or 0002 or 0003 You can browse through the menus with the OK key 5 1 PARAMETER SETTINGS 5 1 1 Language Device language is changed 0003 With 0003 the crane hoist system equip...

Страница 10: ...turned off with the power button 5 1 3 Match Equipment The equipment that will work with the hand terminal is selected 5 1 4 Stable Duration Indicates the time at which the weight weight data becomes...

Страница 11: ...the screen It can be changed to kg t lb kN 5 1 8 Number of Transmitters The number of transmitters used is entered Maximum 16 transmitters are entered 5 1 9 Reset Percentage Indicates in which state...

Страница 12: ...Channel assignment is made for the transmitter used in the load cell The transmitter to be assigned channels is kept open and the others are turned off 5 1 12 Number Setting Number assignment is made...

Страница 13: ...5 1 13 Time Clock setting can be made with the up down right left buttons 5 1 14 Date Date setting can be made with the up down right left buttons...

Страница 14: ...crane hoist system It can be selected from 0 to 5 If the hardware rope is desired to be changed the password 0003 is entered as below without the need to perform a recalibration process and the desire...

Страница 15: ...0 000 000 5 2 4 LoadCell Capacity The maximum capacity value of LoadCell is entered Example 10000 kg 5 2 5 Calibration processes For load calibration or mV calibration the relevant transmitter is left...

Страница 16: ...alibration a calibration load of at least 1 3 of the capacity is placed on the platform and the OK key is pressed In the menu displayed in load calibration the loaded internal count value is taken the...

Страница 17: ...6 Menu Tree 6 1 Parameter Menu...

Страница 18: ......

Страница 19: ......

Страница 20: ...6 2 Calibration Menu 6 2 1 Load Calibration...

Страница 21: ......

Страница 22: ...6 2 2 mV Calibration...

Страница 23: ......

Страница 24: ...6 3 Crane Hoist System Menu...

Отзывы: