28 www.grupotemper.com
KPAW-01
TRUE RMS 1000A AC WATT Clamp Meter
Then press
SEL
again to choose the third phas, see
figure 20.
Press
SEL
to choose the third phase , see figure 20.
Figure 20
5. When measuring 3 phase 3 wires:
The first phase and third phase operating method is
same as 3 phase 4 wires.
Jump over the second phase measurement.
6. MAXMIN button are not valid when measuring power
factor.
F. Active Energy (main display) + Time (secondary
display) Measurement
Warning
To avoid damages to the Meter or harms to you, do you
measure higher than AC voltage 750V rms and AC
current 1000A rms.
To test for Active Energy (main display) + Time
(secondary display), connect the Meter as follows:
1. Dial Rotary to
ENERGY
range.
2. Press the lever to open the transformer jaw, and clamp
them to the corrresponding phase of tested conductor. If