Instructions manual | 

www.grupotemper.com 

KPA 01

Digital clamp multimeter

Diode

Range

Resolution

Accuracy

0.001V

Displays approximate forward voltage.

- Forward DC current: about 1mA
- Open circuit voltage: about 2.8V
- Overload protection: 250V DC or AC (RMS)

Temperature

Range

Resolution

Accuracy

-10ºC~500ºC

(-14°F to 932°F)

0.1°C/0.2°F

±1.0% of r 0.8°C

(±1.0% of r 0.8°F)

-40°C~-10°C

(-40°F to-14°F)

±5.0% of r 1.5°C

(±5.0% of r 3.3°F)

Note: The accuracy does not include K-type thermocouple error.

AC μA Current

Range

Resolution

Accuracy

200.0μA

0.1μA

±(1.0% of r 5 digits)

2000μA

1μA

- Frequency range: 50 ~ 60Hz;
- Overload protection: 250V DC or AC (RMS)

DC μA Current

Range

Resolution

Accuracy

200.0μA

0.1μA

±(1.0% of range + 5 digits)

2000μA

1μA

- Overload protection: 250V DC or AC (RMS)

Содержание KPA 01

Страница 1: ...KPA 01 Pinza amperimétrica Digital clamp multimeter www grupotemper com ...

Страница 2: ...omendaciones previas 3 Durante el uso 3 Símbolos de Seguridad 4 Mantenimiento 4 Características y componentes 5 Componentes 5 Botones e interruptores 6 Descripción de la pantalla 6 Especificaciones 7 Especificaciones generales 7 Especificaciones técnicas 8 Instrucciones de uso 13 Mantenimiento 18 Accesorios 19 ...

Страница 3: ...cciones contra descargas eléctricas Protección del medidor frente a un uso inapropiado Revise el medidor y sus accesorios cuando lo reciba Compruebe si ha sido dañado durante el envío Mantenga las puntas de prueba en buenas condiciones Antes de su utilización compruebe que el aislamiento de las mismas no ha sido dañado y no haya ningún cable expuesto Utilice las puntas de prueba suministradas para...

Страница 4: ...dor cerca de gases explosivos vapor o suciedad y en ambientes con alta presión y temperaturas excesivas Deje de utilizar el medidor si observa algún tipo de anormalidad o incidencia Nunca use el medidor a menos que la cubierta trasera y la tapa de la pila estén en su lugar y completamente cerradas No exponga el medidor a la luz directa del sol ni exponga las baterías a la humedad a fuertes campos ...

Страница 5: ...rtátil con pantalla LCD y retroiluminación de pantalla para facilitar la lectura Su diseño que permite operar y manejar con una sola mano su interruptor hace que la medición resulte fácil y sencilla Apto para profesionales o aficionados e ideal para su uso en centros educativos o en el hogar Escala manual y automática Botón de retención de lecturas Medición máxima Medición Mínima Frecuencia en mod...

Страница 6: ... corriente de entrada MAX MIN lecturas máx mín Rotary Switch selector de funciones de medición Toma INPUT toma de entrada para mediciones de tensión resistencia frecuencia ciclo de trabajo capacitancia diodo continuidad y temperatura Toma COM toma de entrada común Descripción de la pantalla CA CC Diodo Continuidad AUTO Escala automática MAX MIN Valor máximo Valor Mínimo INR Corriente de entrada RE...

Страница 7: ...emperatura de 18ºC a 28ºC y una humedad relativa por debajo del 75 Especificaciones generales Modo manual y automático Protección contra sobrecargas Max tensión entre terminales y toma de tierra 1000V DC or 1000V AC Máx altitud de funcionamiento 2000m Pantalla LCD Valor max en pantalla 5999 Indicación de polaridad indica polaridad negativa Indicación de sobrecarga 0L o 0L Tasa de muestyreo 4 veces...

Страница 8: ...frecuencia 50 60Hz Corrtiente CC Escala Resolución Precisión 600A 0 1A 3 de lect 10 digitos 1000A 1A Máx corriente de entrada 1000A DC Flujo de corriente de entrada Escala Resolución Precisión 600A 0 1A 60A solo como referencia 10 de lect 60 digitos 1000A 1A Tiempod eintegración 100ms Escala de medición 60 1000A Tensión CC Escala Resolución Precisión 600mV 0 1mV 0 5 de lect 3 digitos 6V 0 001V 60V...

Страница 9: ... máxima de entrada 600V CA RMS o 600V CC Escala de frecuencia 50 60Hz Escala 600mV sólo presionando el botón RANGE Nota Ante una escala de tensión pequeña pueden mostrarse lecturas inestables antes de conectar al circuito las puntas de prueba Este hecho es normal ya que el medidor es extremadamente sensible Cuando conectemos las puntas de prueba al circuito se reflejarán las verdaderas lecturas Fr...

Страница 10: ...e de entrada aumentará según aumente la frecuencia del circuito Medición de la frecuencia mediante el modo HZ Escala Resolución Precisión 60Hz 0 01Hz 0 3 de lect 5 digitos 600Hz 0 1Hz 6kHz 1Hz 60kHz 0 01kHz 600kHz 0 1kHz 6MHz 1kHz 60MHz 0 01MHz Señal de entrada VPP 3V onda cuadrada protección contra sobrecargas 250V CC or CA RMS Ciclo de trabajo Escala Resolución Precisión 5 95 0 1 3 0 Cuandos se ...

Страница 11: ...ontra sobrecargas 250V CC o CA RMS Continuidad Escala Resolución Precisión 0 1Ω El medidor pitará si la medición es menor de 50Ω Protección contra sobrecargas 250V CC o CA RMS Tensión del circuito abierto aprox 3V Capacitancia Escala Resolución Precisión 6nF 0 001nF 5 0 de lect 5 digitos 60nF 0 01nF 4 0 de lect 5 digitos 600nF 0 1nF 6μF 0 001μF 60μF 0 01μF 600μF 0 1μF 6mF 0 001mF 60mF 0 01mF Prote...

Страница 12: ...cala Resolución Precisión 10ºC 500ºC 0 1 C 1 0 de lect 0 8 C 1 0 de lect 0 8 F 40 C 10 C 5 0 de lect 1 5 C 5 0 de lect 3 3 F Nota la precisión no incluye el error de la sonda termopar Corriente CA μA Escala Resolución Precisión 200 0μA 0 1μA 1 0 de lect 5 digitos 2000μA 1μA Escala de frecuencia 50 60Hz Protección contra sobrecargas 250V CC o CA RMS Corriente CC μA Escala Resolución Precisión 200 0...

Страница 13: ...linterna 1 Presione el botón RANGE durante 2 segundos para activar la retroiluminación durante 20 segundos tras los cuales se apagará automáticamente 2 Presione el botón RANGE durante 2 segundos para apagarla 3 En el modo de medición de corriente el encendido de la retroiluminación también implica el de la linterna Note la linterna y la retroiluminación utilizan bombillas LED y aunque se apagan au...

Страница 14: ... únicamente funciona en modo manual Corriente de Entrada INRUSH Cuando esté en el modo medición de corriente CA pulse el botón INRUSH para entrar en modo medición de corriente de choque Pulse de nuevo el botón para volver al modo normal Auto apagado 1 Si no se utiliza el medidor se apaga automáticamente transcurridos 20 minutos 2 Para encenderlo de nuevo pulse cualquier botón 3 La función de auto ...

Страница 15: ...e tensión 1 Conecte la punta de prueba negra y la roja a las tomas COM e INPUT respectivamente y seleccione la escala adecuada 2 Coloque el selector en la posición V La medición de tensión CA viene fijada por defecto pulse el botón FUNC para seleccionar tensión CC 3 Para medir mV pulse el botón RANGE hasta llegar al rango mV 4 Conecte las puntas de prueba a la carga o fuente de alimentación 5 Lea ...

Страница 16: ...mediciones de resistencias superiores de 1MΩ puede durar unos segundos debido a la alta resistencia de los circuitos Prueba de diodos 1 Conecte la punta de prueba negra a la toma COM y la roja a la toma INPUT 2 Gire el selector a la posición y pulse FUNC dos veces hasta 3 Conecte el extremo de la punta de prueba roja al ánodo y el extremo de la punta de prueba negra al cátodo del diodo a probar To...

Страница 17: ...a presionando el gatillo e inserte el coductor a medir 4 Conecte la alimentación del circuito a medir 5 El valor más alto se mantendrá en la pantalla Nota 1 No coloque más de un cable en el medidor puede ocasionar a falsas lecturas 2 Asegúrese de colocar el cable centrado en la pinza 3 Si existe sobrecarga la pantalla mostrará el símbolo OL Si es posible seleccione una escala más alta Temperatura ...

Страница 18: ...0V el indicador de NCV emitirá una luz y un sonido Nota 1 Puede que exista tensión incluso si no se nos indica No confíe únicamente en el detector de NCV para determinar la presencia de tensión en un cable Las mediciones pueden variar dependiendo del fabricante el diseño el aislante u otros factores externos 2 El indicador sensible a la tensión puede que se encienda si existe una fuente de tensión...

Страница 19: ...polaridad de las pilas sea la correcta Cambio de las puntas de prueba Atención Reemplace las puntas de prueba por unas del mismo modelo o compatibles Especificaciones de las puntas 1000V 10A Una punta de prueba debe cambiarse siempre que la cubierta de aislamiento que la protege haya sido dañada por ejemplo si los cables interiores están a la vista Accesorios Puntas de prueba Clas 1000V 10A 1 par ...

Страница 20: ...nformation 21 Preparation 21 Usage 21 Safety Symbols on the meter 22 Maintenance 22 Features and Components 23 Components 23 Buttons and switches 24 Display Description 24 Specifications 25 General Specifications 25 Technical Specifications 26 Operations Guide 31 Maintenance 36 Accessories 37 ...

Страница 21: ...eter or any components were damaged during shipment Inspect test leads and probes for cracks breaks or crazes on the insulation before using the meter Use test leads provided with the unit If necessary replace test leads with identical specifications Usage Turn the rotary switch to the required function and range to be measured Never use the meter to measure voltages that might exceed 600V DC AC a...

Страница 22: ... refer to user manual High voltage Compliance with requirements for double insulation CAT III Refers to the impulse withstand voltage protection level in accordance with IEC 61010 1 standard overvoltage installation category III pollution degree 2 Meter complies with European Community CE standards Earth ground Maintenance To avoid electric shock or personal injury repairs or servicing not covered...

Страница 23: ...nual range Reading Hold function Max measurement Min measurement Frequency in clamp mode Auto power off Relative measurement Inrush measurement Components 1 Non Contact Voltage detection sensor 2 NCV indicator 3 Work light 4 Rotary Switch 5 Function buttons 6 Input sockets 7 Clamp trigger 8 Clamp for current measurement 1 2 3 4 5 6 7 8 CAT ll 1000V A Hz T RMS Inrush TEMP Hz μA Ω A V REL ZERO FUNC ...

Страница 24: ...n measure Inrush current MAX MIN button switch between max min readings Rotary Switch switch between measurements INPUT jack voltage current resistance capacitance diode continuity frequency duty cycle temperature input terminal COM jack common input terminal Display Description AC DC Diode Continuity AUTO Auto range MAX MIN Maximum Minimum display INR Inrush REL Relative measurement mode Auto Pow...

Страница 25: ...han 75 General Specifications Manual and Auto Mode Power Overload Protection Maximum Voltage Between Circuit and Ground 1000V DC or 1000V AC Maximum Working Height 2000m Display LCD Maximum Display Number 5999 Auto Polarity Indication Indicates Negative Overload Indication 0L Or 0L Sampling Frequency 4 Times Sec Units Display Display Functions and Units Auto Power Off 20 Minutes Input Power 4 5V D...

Страница 26: ... input current 1000A AC Frequency range 50 60Hz DC Current Range Resolution Accuracy 600A 0 1A 3 of reading 10 digits 1000A 1A Maximum input current 1000A DC Inrush Current Range Resolution Accuracy 600A 0 1A 60A for reference only 10 reading 60 digits 1000A 1A Integration time 100ms Measuring range 60 1000A DC Voltage Range Resolution Accuracy 600mV 0 1mV 0 5 of reading 3 digits 6V 0 001V 60V 0 0...

Страница 27: ...00V 0 1V 1000V 1V Maximum input voltage 600V AC RMS or 600V DC Frequency range 50 60Hz 600mV range only by pressing RANGE button Note At small voltage ranges unsteady readings will appear before the test leads make contact with the circuit This is normal since the Meter is highly sensitive When the test leads are connected to the circuit the true reading will be shown Frequency Frequency through C...

Страница 28: ...ge 20mA AC RMS Input current should increase as circuit frequency increases Frequency Through HZ Mode Range Resolution Accuracy 60Hz 0 01Hz 0 3 of reading 5 digits 600Hz 0 1Hz 6kHz 1Hz 60kHz 0 01kHz 600kHz 0 1kHz 6MHz 1kHz 60MHz 0 01MHz Input signal VPP 3V square wave Overload Protection 250V DC or AC RMS Duty Cycle Range Resolution Accuracy 5 95 0 1 3 0 When measuring frequencies 60KHz duty cycle...

Страница 29: ...0 1MΩ Overload protection 250V DC or AC RMS Continuity Range Resolution Accuracy 0 1Ω The Meter will beep if measurement is less than 50 Overload protection 250V DC or AC RMS Open circuit voltage about 3V Capacitance Range Resolution Accuracy 6nF 0 001nF 5 0 of reading 5 digits 60nF 0 01nF 4 0 of reading 5 digits 600nF 0 1nF 6μF 0 001μF 60μF 0 01μF 600μF 0 1μF 6mF 0 001mF 60mF 0 01mF Overload prot...

Страница 30: ...racy 10ºC 500ºC 14 F to 932 F 0 1 C 0 2 F 1 0 of reading 0 8 C 1 0 of reading 0 8 F 40 C 10 C 40 F to 14 F 5 0 of reading 1 5 C 5 0 of reading 3 3 F Note The accuracy does not include K type thermocouple error AC μA Current Range Resolution Accuracy 200 0μA 0 1μA 1 0 of reading 5 digits 2000μA 1μA Frequency range 50 60Hz Overload protection 250V DC or AC RMS DC μA Current Range Resolution Accuracy...

Страница 31: ... the display backlight the backlight will stay on for 20 seconds before it is automatically turned off 2 When the backlight is on press the RANGE for 2 seconds to turn off the backlight 3 In current mode turning on the backlight will also trigger the clamp light Note Backlight clamp light uses and LED even though the light will auto off after 20 seconds use only when needed to conserve power Maxim...

Страница 32: ...C Current measurement mode press the INRUSH button to enter surge current measurement mode Press button again to return to normal mode Auto Power Off 1 When not in use the meter will automatically turn off after 20 minutes 2 After Auto Off press any button to bring power back on 3 To disable Auto Off hold ZERO REL when turning on the Meter 4 When auto power off is on symbol appears on screen When ...

Страница 33: ...ERO REL button to reset the reading to zero Voltage Measurement 1 Insert the black test leads into COM input and red test lead into INPUT input choose proper range 2 Move rotary switch to V position AC voltage is default measurement Press FUNC to switch to DC voltage 3 For mV measurement press RANGE button until in mV range 4 Connect test leads to voltage source or load 5 Voltage measurement will ...

Страница 34: ...r will take a few seconds to stabilize the reading this is normal for high resistance measurements Diode Test 1 Insert the black test leads into COM input and red test lead into INPUT input 2 Turn rotary switch to position and push FUNC twice for diode test 3 Connect the black lead to the cathode and the red lead to the anode and read the value from the LCD Note The meter displays the forward bias...

Страница 35: ...er and inserting the conductor to be measured 4 Power on the circuit being tested 5 Largest value will be held on main display Note 1 Measuring two or more wires together will cause false readings 2 The wire being measured should be centered within the clamp 3 The Meter displays OL if the circuit is overloaded Choose a larger range if possible 4 Choose the largest range if the range of the circuit...

Страница 36: ...active sensitivity between 1 4 if the sensor at the top of the clamp gets close to a live conductor AC voltage 90V the NVC indicator will flash and buzzer will sound Note 1 Even though there is no indication voltage may still exist Do not rely solely on NCV detector to determine the presence of voltage in a wire The measurement may be affected by the design of the outlet type of insulation and oth...

Страница 37: ... batteries 4 Replace the battery cover and tighten screws Note Be sure to note the battery polarity when replacing Test Leads Replacement Warning Replace the test leads with identical or compatible leads Lead spec 1000v 10a Replace new leads if the current leads are worn Accessories Test Leads Rating 1000V 10A 1 pair User s manual 1pc Batteries AAA battery 3pc K Type thermocouple 1pc Multi functio...

Страница 38: ...38 Instructions manual www grupotemper com KPA 01 Digital clamp multimeter ...

Страница 39: ...AL S L garantit cet apareil pour le durée de 2 annèes contre tout défault de fabrication Pour le service de garantie vous devez présenter ce reçu avec du ticket de caisse ou la facture TEMPER ENERGY INTERNATIONAL S L garantía este aparelho contra defeitos de fábrica ate 2 anos Para o serviço de garantia você deve apresentar este recibo com o recibo de compra ou fatura GARANTÍA WARRANTY GARANTIE GA...

Страница 40: ...TEMPER ENERGY INTERNATIONAL S L Polígono industrial de Granda nave 18 33199 Granda Siero Asturias Teléfono 34 902 201 292 Fax 34 902 201 303 Email info grupotemper com Una empresa del grupo ...

Отзывы: