KCTE-80
Thermal Imager
www.grupotemper.com
6.12-Reflected Temperature
Using the offset factor, the reflection is calculated out due to the low emissivity and the accuracy of
thetemperature measurement with infrared instruments is improved. In most cases, the reflected temperature is
identical to the ambient air temperature. Only when objects with strong emissions with much higher temperature
are in the proximity of the object being measured should be determined and used. The reflected temperature has
only little effect on objects with high emissivity. The reflected temperature can be set individually.
Follow these steps to get the right value for the reflected temperature.
1-Set the emissivity to 1.0
2-Adjust the optical lens to near focus
3-Looking in the opposite direction away from the object, take a measurement and freeze the image
4-Determine the average value of the image and use that value for your input of reflected temperature.
6.13-Thermal Imager Reporter Software
Thermal Imager Reporter software is supplied with the Thermal Imager. This Software is intended for
Thermal Imager and contains feature to analyze images, organize data and information, and make professional
reports. Thermal ImagerReportersoftwareallowsaudioannotationsandcommentarytobereviewedonaPC.
7-Menus
The menus, together with buttons, are access for image, measurement, Emiss, Palette, temperature
measurement range, take photo and video, review, and settings.
7.1-Main Menu
Main Menu is the main interface of the Thermal Imager‟s menus.
It contains six items such as Measure, Emiss, Image, Palette,
Temperature measurement range, Settings.
Measure:
set for the calculation and display of radiometric
temperature measurement data related to the thermal images.
Emiss:
Setting the materials type and the emissivity of the
measured object, you can also set the environment reflected
temperature.
Image:
set image source for the display on the Thermal Imager‟s
LCD. It contains six items such as infrared image, visual image and
fusion.
Palette:
set the type of color bar.
Range:
set the temperature measurement range.
Settings:
set for the user preferences such as language, unit of
temperature measurement, date, time. restore factory setting and
display product information.
Содержание KCTE-80
Страница 1: ...www grupotemper com KCTE 80 C mara Termogr fica C mara Termogr fica Imageur thermique Thermal Imager...
Страница 34: ...KCTE 80 im genes t rmicas www grupotemper com...
Страница 46: ...KCTE 80 im genes t rmicas www grupotemper com...
Страница 48: ...KCTE 80 im genes t rmicas www grupotemper com...
Страница 50: ...KCTE 80 im genes t rmicas www grupotemper com...
Страница 114: ......