INSTALLATION:

 (see the diagram) 

  Shut off power. 

  Loosen  the  screw on  the  bottom  lid,  open 

the wiring hole, pass the wire of power and 

load through the bottom lid. 

  Fix the bottom lid with inflated screw on the 

selected position. 

  Connect  the  power  and  load  wire  into 

connection-wire column according to the connecting figure. 

  Put the sensor on the bottom lid, twist the screw tightly then electrify it and test it. 

 

CONNECT-WIRE FIGURE 

(See the right figure) 

 

 

 

TEST: 

  Turn  time  knob  anti-clockwise  to  the  minimum;  turn  the 

LUX  knob clockwise  to the maximum  (SUN),  Switch on 

power,  the  controlled  load  should  not  work,  needing  to 

preheat

 

within

 

5-30sec. 

  The  sensor  will  be  sensed  again  in  5-10sec  later  when 

the first induction is finished, the load should work when 

received sensor signal and stop working within 7-13sec 

with no any sensor signal. 

  Turn LUX knob to minimum anti-clockwise, if you test it when the ambient light is more than 

10LUX, the induction load would not work after the load stops working; the load should work 

if you cover the detection window with opaque object (towel etc),it would be regular the load 

stops to work within 7-13sec under no induction signal condition. 

Note: when testing in daylight, please turn LUX knob to            (SUN)   

position, otherwise the sensor lamp could not work! 

NOTE: 

  Should be installed by electrician or experienced person. 

  Avoid installing it on the unrest object. 

  There should be no hindrance and moving objects in front of the detection windows to effect 

detection. 

  Avoid installing it near air temperature alteration zones such as air condition, central heating, 

etc. 

  Considering  your  safety,  please  do  not  open  the  cover  when  you  find  the  hitch  after 

installation. 

  If  there  is  difference  between  instruction  and  the  function  the  product  has,  please  give 

priority to product and sorry not to inform you additionally. 

SOME PROBLEM AND SOLVED WAY: 

  The load do not work: 

a. please check if the connection-wiring of power and load is correct. 

b. please check if the load is good . 

c. please check if the working light set correspond to ambient light. 

  The sensitivity is poor: 

a. Please check if there has hinder in front of the detection window to effect to receive 

the signal. 

b. Please check if the ambient temperature is too high. 

c. Please check if the induction signal source is in the detection fields. 

d.  Please  check  if  the  installation  height  corresponds  to  the  height  showed  in  the 

instruction. 

e. Please check if the moving orientation is correct. 

  The sensor can not shut off the load automatically: 

a. Please check if there is continual signal in the detection field. 

b. Please check if the time delay is the longest. 

c. Please check if the power correspond to the instruction. 

d.  Please  check  if  the  temperature  near  the  sensor  change  obviously,  such  as  air 

condition or central heating etc. 

 

Содержание 0767965

Страница 1: ... min 10sec 3sec Installation Height 2 2 4m Max 7min 2min Power Consumption 0 9W work Rated Load 100W incandescent lamp 0 9W static 100W energy saving lamp or LED Detection Motion Speed 0 6 1 5m s FUNCTION Detection field The wide detection range is made up of up and down left and right see the following diagram the detection range could be adjusted according to your desire but the moving orientati...

Страница 2: ...TE Should be installed by electrician or experienced person Avoid installing it on the unrest object There should be no hindrance and moving objects in front of the detection windows to effect detection Avoid installing it near air temperature alteration zones such as air condition central heating etc Considering your safety please do not open the cover when you find the hitch after installation I...

Страница 3: ...ltura de instalación 2 2 4m Max 7min 2min Consumo de potencia 0 9W trabajoa Rated Load 100W luz incandescente 0 9W reposo 100W lámpra ahorro de energía o LED Velocidad de detección de movimiento 0 6 1 5m s FUNCIONES Campo de detección arriba y abajo izquierda y derecha ver el esquema El rango de detección se puede ajustar según su deseo La orientación en movimiento en el campo de detección tiene u...

Страница 4: ...lámpara del sensor no funcionará NOTAS Debe ser instalado por un electricista o una persona con experiencia No debe haber obstáculos delante de la fotocélula que afecten a la luz natural recibida No debe haber obstáculos ni objetos en movimiento frente a los campos de detección Evite instalarlo cerca de zonas de alteración de la temperatura del aire por ejemplo aire acondicionado calefacción etc P...

Страница 5: ... Trabalho 93 RH Atraso Min 10sec 3sec Altura de instalação 2 2 4m Max 7min 2min Consumo de energia 0 9W trabalho Carga Nominal 100W lâmpada incandescente 0 9W estático 100W lâmpada economizadora de energia ou LED Velocidade de detecção de movimento 0 6 1 5m s FUNÇÃO Campo de detecção A ampla faixa de detecção é composta por cima e para baixo esquerda e direita veja o diagrama a seguir a faixa de d...

Страница 6: ...a a posição SUN caso contrário a lâmpada do sensor não funcionará NOTA Deve ser instalado por eletricista ou pessoa experiente Evite instalá lo no objeto instável Não deve haver nenhum obstáculo e objetos em movimento na frente das janelas de detecção para efetuar a detecção Evite instalá lo perto de zonas de alteração de temperatura do ar como ar condicionado aquecimento central etc Para sua segu...

Страница 7: ...e 10 2000LUX adjustable Humidité de travail 93 RH Temporisation Min 10sec 3sec Hauteur d installation 2 2 4m Max 7min 2min Consommation d énergie 0 9W travail Charge nominale 100W lampe à incandescence 0 9W statique 100W lampe à économie d énergie ou LED Detection Motion Speed 0 6 1 5m s FONCTION Champ de détection La large plage de détection est composée de haut en bas de gauche et de droite voir...

Страница 8: ...n signal de capteur Tournez le bouton LUX au minimum dans le sens anti horaire si vous le testez lorsque la lumière ambiante est supérieure à 10LUX la charge d induction ne fonctionnera pas après que la charge cesse de fonctionner la charge devrait fonctionner si vous couvrez la fenêtre de détection avec un objet opaque serviette etc il serait normal que la charge s arrête pour fonctionner dans le...

Страница 9: ... la hauteur d installation correspond à la hauteur indiquée dans les instructions e Veuillez vérifier si l orientation de déplacement est correcte Le capteur ne peut pas arrêter la charge automatiquement a Veuillez vérifier s il y a un signal continu dans le champ de détection b Veuillez vérifier si le délai est le plus long c Veuillez vérifier si la puissance correspond à l instruction d Veuillez...

Отзывы: