5
*8888#, hear three beeps, input #5, hear three, hang up, down.
After the power is turned on, the automatic dialing is canceled.
(6) Restore factory settings: input *****#, automatically hang up after hearing the tone, and clear all
configurations next time.
3.4. How to store the number (handle mode method)
Remote deposit number: by calling the unit
(1) Use any DTMF phone to call the unit.
(2) After several ringtones, lift the handset and enter the number setting status directly by entering the password.
(3) Set the four groups of speed dial numbers, enter *8888#, after inputting correctly, hear three beeps, then
input (#1-#4), then enter the number to be stored (0-9), after setting.
Hang up, the next boot will take effect.
(4) Lift the machine automatic dialing number setting, enter *8888#, after inputting correctly, hear three prompts,
then input #5, then input the number to be stored (0-9), set it up, hang up, next time boot Effective.
(5) Number clearing: Use any DTMF phone to call the machine. After several ringtones, lift the handset, enter
*8888#, hear three beeps, input (#1-#5), hear the prompt tone for 3 times, hang up, automatically dialed after the
next boot.
Local deposit number:
The local deposit and clear number methods are the same as the remote deposit method (models must have
button support).
Some models with induction loop refer to the following parameters
Built-in induction loop part
Help the elderly and some of the disabled people can use this phone normaly.
With induction loop coverage 1M radius.
Spec for this induction loop part:
- Supply voltage : DC12V;
- Max operation current: 5A;
- Inputs: internal electret microphone,Noise reduction microphone.
- Microphone: sensitivity:66Dbm to -2Dbm bandwidth 50Hz to 20Khz.
- Overail Performance: bandwidth at any output level 50Hz to 15Khz.