Page 11
Page 12
KNOX VIDEO
RS16x16HB Routing Switcher
KNOX VIDEO
RS16x16HB Routing Switcher
and audio xx and zz are cross-connected.
To cross-connect video only, send a six-byte command in the form:
Kxxyy(ENTER)
and to cross-connect audio only, send a six-byte command in the form:
Lxxyy(ENTER)
For example, K0113 connects video input 13 to output 1 and video input 1 to
output 13.
3.4.5 READING SYSTEM STATUS
The crosspoint status can be read from the RS232 port at any time by sending
the two-byte command:
D (ENTER)
The status report does not disturb the existing crosspoint pattern.
3.4.6 STORING AND RECALLING CROSSPOINT PATTERNS
To STORE the currently loaded crosspoint pattern to one of the sixteen
pattern storage areas, send the four-byte command:
Snn (ENTER),
where nn is a number from 0l to 16. The pattern stored in that memory area will be
overwritten with the current pattern.
To RECALL and load one of the sixteen crosspoint patterns from the battery
backed-up memory, send the four-byte command:
Rnn (ENTER),
where nn is a number from 0l to 16.
3.4.7 TIMED SEQUENCER
The RS16x16HB can be set to cycle continuously through its sixteen stored
patterns on a timed basis. To set the time interval and start the cycling send the
four-byte command:
Tnnn (ENTER),
where nnn is a one- to three-digit number from 1 to 999.
To stop the cycling, send the two-byte command:
N(ENTER).