Knox Video RS16x16HB Скачать руководство пользователя страница 6

Page 11

Page 12

KNOX VIDEO

RS16x16HB Routing Switcher

KNOX VIDEO
RS16x16HB Routing Switcher

and audio xx and zz are cross-connected.

To cross-connect video only, send a six-byte command in the form:

Kxxyy(ENTER)

and to cross-connect audio only, send a six-byte command in the form:

Lxxyy(ENTER)

For example, K0113 connects video input 13 to output 1 and video input 1 to

output 13.

3.4.5   READING SYSTEM STATUS

The crosspoint status can be read from the RS232 port at any time by sending

the two-byte command:

D (ENTER)

The status report does not disturb the existing crosspoint pattern.

3.4.6   STORING AND RECALLING CROSSPOINT PATTERNS

To STORE the currently loaded crosspoint pattern to one of the sixteen

pattern storage areas, send the four-byte command:

Snn (ENTER),

where nn is a number from 0l to 16. The pattern stored in that memory area will be
overwritten with the current pattern.

To RECALL and load one of the sixteen crosspoint patterns from the battery

backed-up memory, send the four-byte command:

Rnn (ENTER),

where nn is a number from 0l to 16.

3.4.7   TIMED SEQUENCER

The RS16x16HB can be set to cycle continuously through its sixteen stored

patterns on a timed basis. To set the time interval and start the cycling send the
four-byte command:

Tnnn (ENTER),

where nnn is a one- to three-digit number from 1 to 999.

To stop the cycling, send the two-byte command:

N(ENTER).

Содержание RS16x16HB

Страница 1: ...space in the rack which is convenient for all the cables and mount the unit using standard rack bolts Connect the output of the RS16x16HB power unit to the power connector at the right rear as viewed...

Страница 2: ...answerback verbose and nonverbose Select the mode using position 3 of the programming switch located on the rear panel of the RS16x16HB Position 3 ON is verbose while position 3 OFF is nonverbose The...

Страница 3: ...ing has no meaning unless the inputs are synchro nous to one another SECTION 3 OPERATION 3 1 INTRODUCTION This section explains in detail the operation of the RS16x16HB using either the front panel ke...

Страница 4: ...the S key enter 92 followed by a 2 digit number from 0l to 99 then push the ENter key The 2 digit number corre sponds approximately to the number of seconds between pattern changes To begin the cyclin...

Страница 5: ...l command is received then all the commands are executed at the same time For all but the final command in the set use the form Exxyy ENTER where xx is the output number and yy is the input number Usi...

Страница 6: ...3 4 6 STORINGANDRECALLINGCROSSPOINTPATTERNS To STORE the currently loaded crosspoint pattern to one of the sixteen pattern storage areas send the four byte command Snn ENTER where nn is a number from...

Страница 7: ...for changing the battery should be performed by qualified service people only 4 1 INTRODUCTION The only routine maintenance the RS16x16HB requires is to change the battery located at the rear of the R...

Страница 8: ...4 ON locks out keypad entry Switch position 5 is used to disable breakaway audio Position 5 OFF allows breakaway audio while position 5 ON causes audio to always switch with video Switch positions 6...

Отзывы: